If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-033-27049 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.173775,"lon":-78.572831,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Clearfield | |
Municipality: Huston Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 149476 | |
Farm/Lease Name: TURKEY 590983 | |
License Status: Active | |
Spud Date: 2011-09-25 | |
Permit Date: 2011-07-19 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 41.173775 | |
Longitude: -78.572831 |
Date | Event |
---|---|
2011-07-19 | New Permit Application |
2011-09-25 | Performed Spud Operation |
2012-03-22 | New Permit Application |
2012-11-15 | Drilling Completion |
2014-06-27 | Perforation |
2014-06-27 | Performed Stage 1 of Stimulation |
2014-06-28 | Perforation |
2014-06-28 | Performed Stage 1 of Stimulation |
2014-06-28 | Performed Stage 2 of Stimulation |
2014-06-28 | Performed Stage 3 of Stimulation |
2014-06-28 | Performed Stage 4 of Stimulation |
2014-06-29 | Perforation |
2014-06-29 | Performed Stage 5 of Stimulation |
2014-06-29 | Performed Stage 6 of Stimulation |
2014-06-29 | Performed Stage 7 of Stimulation |
2014-06-29 | Performed Stage 8 of Stimulation |
2014-06-30 | Perforation |
2014-06-30 | Performed Stage 10 of Stimulation |
2014-06-30 | Performed Stage 11 of Stimulation |
2014-06-30 | Performed Stage 12 of Stimulation |
2014-06-30 | Performed Stage 9 of Stimulation |
2014-07-01 | Perforation |
2014-07-01 | Performed Stage 13 of Stimulation |
2014-07-01 | Performed Stage 14 of Stimulation |
2014-07-01 | Performed Stage 15 of Stimulation |
2014-07-01 | Performed Stage 16 of Stimulation |
2014-07-01 | Performed Stage 17 of Stimulation |
2014-07-02 | Perforation |
2014-07-02 | Performed Stage 18 of Stimulation |
2014-07-02 | Performed Stage 19 of Stimulation |
2014-07-03 | Perforation |
2014-07-03 | Performed Stage 20 of Stimulation |
2019-03-19 | Deviated |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2014-06-27 | 2014-07-03 | 7,320 | 8,804,800 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | MC MX 8-2544 | Nabors | Live Culture-Nitrate Reducing Bacteria | Proprietary non-hazardous | Proprietary | 60 | 0.00600801 | 4905.75 |
Sand (Proppant) | Nabors | Proppant | Silica Substrate | 14808-60-7 | 100 | 9.61943 | 7,854,600.0 | |
Water | Nabors | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 89.9852 | 73,476,000.0 | |
AI-2 | Nabors | Acid Inhibitor | Glycol Ethers | 111-76-2 | 29 | 0.00008802 | 71.875 | |
Benzyl Chloride-Quaternized | 72480-70-7 | 5 | 0.00001518 | 12.392 | ||||
Isopropyl Alcohol | 67-63-0 | 29 | 0.00008802 | 71.875 | ||||
Propargyl Alcohol | 107-19-7 | 30 | 0.00009106 | 74.354 | ||||
Ethoxylated Nonylphenol | 68412-54-4 | 7 | 0.00002125 | 17.349 | ||||
Hydrochloric Acid (15%) | Nabors | Acidizing | Hydrochloric Acid | 7647-01-0 | 15 | 0.0246047 | 20090.6 | |
MC MX 5-2402 | Nabors | Soldium nitrate brine | Sodium nitrate | 7631-99-4 | 60 | 0.0586589 | 47897 | |
LSG-100 | Nabors | Gelling agent | Proprietary non-hazardous polymers | Proprietary | 35 | 0.00544728 | 4447.89 | |
Solvent naphtha | 64742-47-8 | 65 | 0.0101164 | 8260.37 | ||||
Super TSC LT | Nabors | Scale control | Proprietary non-hazardous | Proprietary | 100 | 0.0266595 | 21768.4 | |
OB-2 | Nabors | Gel Breaker | Sillica, crystalline quartz | 7631-86-9 | 30 | 0.00006154 | 50.25 | |
Ammonium Persulfate | 7727-54-0 | 70 | 0.000143595 | 117.25 | ||||
WFR-3B | Nabors | Friction reducer | Ethoxylated alcohols | 68551-12-2 | 15 | 0.0121261 | 9901.38 | |
Hydrotreated Light Distillate | 64742-47-8 | 50 | 0.0404203 | 33004.6 | ||||
Ethoxylated oleylamine | 26635-93-8 | 5 | 0.00404203 | 3300.46 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2014-06-28 | 1 | Sand | 7,602,126 | 8,785 | 9,187 |
2014-06-28 | 2 | Sand | 7,602,126 | 8,697 | 9,140 |
2014-06-28 | 3 | Sand | 7,602,126 | 8,789 | 9,076 |
2014-06-28 | 4 | Sand | 7,602,126 | 8,853 | 9,512 |
2014-06-29 | 5 | Sand | 7,602,126 | 8,958 | 9,554 |
2014-06-29 | 6 | Sand | 7,602,126 | 8,535 | 9,058 |
2014-06-29 | 7 | Sand | 7,602,126 | 8,555 | 9,159 |
2014-06-29 | 8 | Sand | 7,602,126 | 8,750 | 9,196 |
2014-06-30 | 9 | Sand | 7,602,126 | 8,743 | 9,268 |
2014-06-30 | 10 | Sand | 7,602,126 | 8,652 | 9,050 |
2014-06-30 | 11 | Sand | 7,602,126 | 8,719 | 9,126 |
2014-06-30 | 12 | Sand | 7,602,126 | 8,892 | 9,349 |
2014-07-01 | 13 | Sand | 7,602,126 | 8,440 | 9,110 |
2014-07-01 | 14 | Sand | 7,602,126 | 8,307 | 8,964 |
2014-07-01 | 15 | Sand | 7,602,126 | 8,492 | 9,026 |
2014-07-01 | 16 | Sand | 7,602,126 | 8,756 | 9,230 |
2014-07-01 | 17 | Sand | 7,602,126 | 7,959 | 8,776 |
2014-07-02 | 18 | Sand | 7,602,126 | 8,355 | 9,314 |
2014-07-02 | 19 | Sand | 7,602,126 | 8,934 | 9,418 |
2014-07-03 | 20 | Sand | 7,602,126 | 8,069 | 9,598 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | EQT PROD CO | 420,927.00 | 137 | 0.00 | 0 | 0.00 | 0 |
2015 | EQT PROD CO | 585,056.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | EQT PROD CO | 438,869.00 | 360 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 338,998.00 | 353 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 390,948.00 | 354 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 313,411.00 | 364 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | EQT PROD CO | Drilling Fluid Waste | 15,385.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | EQT PROD CO | Produced Fluid | 200.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EQT PROD CO | Produced Fluid | 21,868.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EQT PROD CO | Drilling Fluid Waste | 375.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EQT PROD CO | Produced Fluid | 1,750.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24076 |
2014 | EQT PROD CO | Produced Fluid | 100.00 Bbl | INJECTION DISPOSAL WELL | 34-007-24355 |
2014 | EQT PROD CO | Produced Fluid | 435.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24075 |
2014 | EQT PROD CO | Drilling Fluid Waste | 20.00 Bbl | CENT WASTE TRT FAC NPDES | EPA ID: 748-163 |
2014 | EQT PROD CO | Drilling Fluid Waste | 20.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | EPA ID: 748-163 |
2014 | EQT PROD CO | Produced Fluid | 2,672.00 Bbl | INJECTION DISPOSAL WELL | 34-007-21847 |
2014 | EQT PROD CO | Produced Fluid | 219.00 Bbl | INJECTION DISPOSAL WELL | 34-007-2-3097 |
2014 | EQT PROD CO | Fracing Fluid Waste | 5,872.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EQT PROD CO | Produced Fluid | 1,809.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | EQT PROD CO | Produced Fluid | 120.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | 101677 |
2015 | EQT PROD CO | Produced Fluid | 942.00 Bbl | INJECTION DISPOSAL WELL | 34-007-21847 |
2015 | EQT PROD CO | Produced Fluid | 520.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2015 | EQT PROD CO | Produced Fluid | 100.00 Bbl | INJECTION DISPOSAL WELL | 34-007-23262 |
2015 | EQT PROD CO | Produced Fluid | 390.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2015 | EQT PROD CO | Produced Fluid | 1,695.00 Bbl | CENT WASTE TRT FAC NPDES | EPA ID: 748-163 |
2015 | EQT PROD CO | Produced Fluid | 985.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2015 | EQT PROD CO | Produced Fluid | 195.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20525 |
2015 | EQT PROD CO | Produced Fluid | 502.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | EQT PROD CO | Produced Fluid | 325.00 Bbl | INJECTION DISPOSAL WELL | 34-007-24355 |
2015 | EQT PROD CO | Produced Fluid | 1,695.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | EPA ID: 748-163 |
2015 | EQT PROD CO | Produced Fluid | 14,711.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid | 3,247.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid | 2,191.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016 | EQT PROD CO | Synthetic Liner Materials | 7.83 Tons | LANDFILL | 101397 |
2016 | EQT PROD CO | Produced Fluid | 5,056.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2016 | EQT PROD CO | Other Oil & Gas Wastes | 90.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2017 | EQT PROD CO | Produced Fluid | 3,016.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 30.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Soil Contaminated by Oil & Gas Related Spills | 0.18 Tons | LANDFILL | 100277 |
2017 | EQT PROD CO | Produced Fluid | 2,116.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Produced Fluid | 110.00 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 193.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | EQT PROD CO | Produced Fluid | 327.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | EQT PROD CO | Soil Contaminated by Oil | 0.18 Tons | LANDFILL | 100277 |
2018 | EQT PROD CO | Produced Fluid | 1,443.52 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Produced Fluid | 4,650.57 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | EQT PROD CO | Servicing Fluid | 7.53 Tons | LANDFILL | 301358 |
2018 | EQT PROD CO | Produced Fluid | 24.39 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018 | EQT PROD CO | Produced Fluid | 216.75 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2018 | EQT PROD CO | Produced Fluid | 399.91 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018 | EQT PROD CO | Produced Fluid | 576.45 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 155.13 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 28.60 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2019 | EQT PROD CO | Produced Fluid | 29.80 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2019 | EQT PROD CO | Produced Fluid | 39.13 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2019 | EQT PROD CO | Produced Fluid | 81.53 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2019 | EQT PROD CO | Produced Fluid | 408.60 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2019 | EQT PROD CO | Produced Fluid | 1,623.92 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 298.98 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 223.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2007868 | Primary Facility | 2011-10-04 | Compliance Evaluation | No Violations Noted | |
2014602 | Primary Facility | 2011-10-27 | Compliance Evaluation | No Violations Noted | |
2058870 | Primary Facility | 2012-04-11 | Routine/Complete Inspection | No Violations Noted | |
2101854 | Primary Facility | 2012-09-20 | Drilling/Alteration | No Violations Noted | |
2114896 | Primary Facility | 2012-11-09 | Drilling/Alteration | No Violations Noted | |
2127766 | Primary Facility | 2012-12-21 | Follow-up Inspection | No Violations Noted | |
2130183 | Primary Facility | 2013-01-14 | Routine/Complete Inspection | No Violations Noted | |
2134949 | Primary Facility | 2013-01-31 | Routine/Complete Inspection | No Violations Noted | |
2137025 | Primary Facility | 2013-02-07 | Routine/Complete Inspection | No Violations Noted | |
2143153 | Primary Facility | 2013-01-27 | Routine/Complete Inspection | No Violations Noted | |
2154897 | Primary Facility | 2013-04-09 | Routine/Complete Inspection | No Violations Noted | |
2225268 | Primary Facility | 2013-11-26 | Routine/Complete Inspection | No Violations Noted | |
2253576 | Primary Facility | 2014-03-13 | Routine/Complete Inspection | No Violations Noted | |
2276221 | Primary Facility | 2014-06-04 | Routine/Complete Inspection | No Violations Noted | |
2286463 | Primary Facility | 2014-07-10 | Routine/Complete Inspection | No Violations Noted | |
2313814 | Primary Facility | 2014-10-17 | Routine/Complete Inspection | No Violations Noted | |
2371804 | Primary Facility | 2015-05-21 | Routine/Complete Inspection | No Violations Noted | |
2390877 | Primary Facility | 2015-07-20 | Routine/Complete Inspection | No Violations Noted | |
2393478 | Primary Facility | 2015-07-29 | Routine/Complete Inspection | No Violations Noted | |
2395574 | Primary Facility | 2015-08-05 | Routine/Complete Inspection | No Violations Noted | |
2425264 | Primary Facility | 2015-11-16 | Routine/Complete Inspection | No Violations Noted | |
2450794 | Primary Facility | 2016-02-19 | Site Restoration | No Violations Noted | |
2551051 | Primary Facility | 2017-01-10 | Routine/Complete Inspection | No Violations Noted | |
2686450 | Primary Facility | 2018-01-23 | Routine/Complete Inspection | No Violations Noted | Routine site inspection at EQT Production Company's Turkey Well Pad on January 23, 2018. No one was onsite durning the time of my inspection. There are a total of 5 producing Marcellus wells drilled on this well pad (033-27049, 033-27051, 033-27053, 033-27055, and 033-27057).
The pad was originally permitted for 11 wells but only 5 of the 11 have been drilled to date. All 5 wells are tagged with the API/well # and each well is plumbed to a gas production unit which include metering instrumentation, heater, and fluids separator. Well cellars are covered in metal grates, cellars are approximately half full, no oil sheen or bubbling was observed. There are (5) 400 bbl produced fluids tanks located in secondary containment. Containment appears intact. Approximately 2 inches of water was observed in this containment with a field screen reading of 1989 uS/cm. The well pad has been reduced in size. The original design included (2) lined reserve/cutting pits along the entire SW edge of the Turkey Pad. These pit |
2722647 | Primary Facility | 2018-04-24 | Routine/Complete Inspection | No Violations Noted | I met Steve Shiner and Lance Beloney of Energy Water Solutions when I arrived. The VOX unit was not running; Steve informed me that the volume of water being produced by the wells had allowed them to run the unit for 5 days of 1200 gallon batches, but that there wasn't enough produced water in the production tanks to run a batch that day. So far, the unit has been able to evaporate approximately 20% of each batch before solids began to drop out. The stack test for the RFD is currently scheduled for May 15th. I noted two tanks, both empty, that were not in secondary containment; a 35 gallon propylene glycol tank next to one of the GPUs, and a double tank of methanol near the dehy unit. Although these tanks were empty, they had been in use recently; I recommend that these kinds of tanks be placed in secondary containment in the future. At the production tank containment, I noted that all of the 90 degree elbows on the feed lines to the tank were heavily corroded; one in particular (see photo) appeared to |
2845698 | Primary Facility | 2019-02-27 | Incident- Response to Accident or Event | Viol(s) Noted & Immediately Corrected | On February 27, 2019 Department representative Sue Herzing conducted a incident related inspection at EQT Production's Turkey Well Pad. I met with EQT Senior Compressor Technician Dan Canton on the access road on my way into the Turkey Well Pad. The spill occurred between producing wells 033-27049 and 033-27051. A 130 gallon corrosion inhibitor tote was stationed and connected between both wells. EQT claims that during the recent high winds storm that occurred on Sunday 2/24/19 through Monday 2/25/19, that winds over turned this 130 gallon tote; resulting in ~30 gallons of corrosion inhibitor being released on the well pad.
When I arrived onsite the spill had already been cleaned up and contaminated soils were placed in a lined roll-off box still stationed onsite. The impacted area is triangular in shape ~6 ft. wide and ~8 ft. long (see photos 2-4). New rock was placed in the impacted area. A soil probe was used to screen the rock covered impacted area. No elevated conductivity in the soil/rock were detecte |
2851672 | Primary Facility | 2019-03-11 | Routine/Complete Inspection | No Violations Noted | The weather is 45 Deg. F, windy and sunny at time of inspection. Routine inspection of EQT Production Co., Turkey Pad, Well # 590983 on March 11, 2019. There are 5 active wells on this pad.
This well is open and producing at the time of inspection. Both annular vents (production by intermediate and intermediate by surface) are open and vented to the atmosphere. Unable to verify annular vents for gas using gas meter due to annular vent pipes are being raised up to unreachable height without a ladder. 0% combustible gas was detected in the area immediately surrounding the well. Production tubing pressure is 351 PSI, backside casing pressure 3 PSI. Production processing equipment on location includes 5 production water tanks, 5 gas processing units, 1 sand trap, measurement equipment ¿ orifice meter stations. No violations are noted at time of inspection, but DEP recommends labeling annular vents. DEP Representative - Ulyana Trynovich, Oil and Gas Inspector, Melissa Sue Herzing, Water Quality Specialist. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2845698 | 843143 | 2019-02-27 | 2019-02-27 | CSL 402(b) | Environmental Health & Safety | ~30 gallons of corrosion inhibitor was released to the ground between Marcellus wells 033-27049 and 033-27051. |
2845698 | 843144 | 2019-02-27 | 2019-02-27 | 78a56(a) | Environmental Health & Safety | Failure to contain corrosion inhibitor in temporary storage. |
2845698 | 843145 | 2019-02-27 | 2019-02-27 | SWMA 301 | Environmental Health & Safety | Failure to properly store, transport, process, or dispose of residual waste. |
For data sources see[9]