X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-035-20124

Well Details

Well ID: 37-035-20124
Loading map...
Country: United States
State: Pennsylvania
County: Clinton
Municipality: Leidy Township
Operator Name:
Well Pad ID:
Farm/Lease Name: PA DEPT OF FORESTS & WATERS TRACT 18 LW
License Status: ACTIVE
Spud Date:
Permit Date: 1971-05-12
Well Type: STORAGE WELL
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.472835
Longitude: -77.800113

For data sources see[1][2][3]

Well History

Date Event
1971-01-01 NEWLY DRILLED
1971-05-12 New Permit Application
1971-05-17 Performed Spud Operation
1971-07-28 Perforation
1971-08-06 Drilling Completion

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2003 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2006 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2007 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2008 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2009 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2010 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2011 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2012 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2013 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2014 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2015 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2016 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2017 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2018 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1067694 Primary Facility 2001-10-10 Routine/Complete Inspection No Violations Noted
1174129 Primary Facility 2002-09-30 Routine/Complete Inspection No Violations Noted
1280234 Primary Facility 2003-10-22 Routine/Complete Inspection No Violations Noted
1570276 Primary Facility 2006-10-02 Routine/Complete Inspection No Violations Noted
1661412 Primary Facility 2007-10-16 Routine/Complete Inspection No Violations Noted
1747634 Primary Facility 2008-10-29 Routine/Complete Inspection No Violations Noted
1839618 Primary Facility 2009-10-28 Routine/Complete Inspection No Violations Noted
1923995 Primary Facility 2010-10-26 Routine/Complete Inspection No Violations Noted 3824 ann-0
2014831 Primary Facility 2011-10-12 Routine/Complete Inspection No Violations Noted
2103788 Primary Facility 2012-09-26 Routine/Complete Inspection No Violations Noted
2229788 Primary Facility 2013-10-30 Routine/Complete Inspection No Violations Noted
2320383 Primary Facility 2014-11-06 Routine/Complete Inspection No Violations Noted
2416563 Primary Facility 2015-10-06 Routine/Complete Inspection No Violations Noted
2656662 Primary Facility 2017-10-30 Routine/Complete Inspection No Violations Noted
2790178 Primary Facility 2018-09-26 Routine/Complete Inspection No Violations Noted At the time of this inspection the casing pressure was 3758 pounds per square inch. No violations noted at this inspection.
355125 Primary Facility 1988-10-05 Routine/Complete Inspection No Violations Noted
355126 Primary Facility 1989-10-10 Routine/Complete Inspection No Violations Noted
367111 Primary Facility 1990-10-10 Routine/Complete Inspection No Violations Noted
369870 Primary Facility 1991-10-10 Routine/Complete Inspection No Violations Noted
372713 Primary Facility 1992-10-28 Routine/Complete Inspection No Violations Noted
374688 Primary Facility 1993-10-06 Routine/Complete Inspection No Violations Noted
376764 Primary Facility 1994-10-13 Routine/Complete Inspection No Violations Noted
379204 Primary Facility 1995-10-17 Routine/Complete Inspection No Violations Noted
381271 Primary Facility 1996-10-16 Routine/Complete Inspection No Violations Noted
383496 Primary Facility 1997-10-07 Routine/Complete Inspection No Violations Noted
385970 Primary Facility 1998-10-05 Routine/Complete Inspection No Violations Noted
881368 Primary Facility 1999-10-04 Routine/Complete Inspection No Violations Noted
975542 Primary Facility 2000-10-18 Routine/Complete Inspection No Violations Noted

For data sources see[6]

References