X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-059-26292

Well Details

Well ID: 37-059-26292
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Franklin Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 150363
Farm/Lease Name: BEDILION UNIT 3H
License Status:
Spud Date: 2014-04-24
Permit Date: 2013-11-22
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 39.936806
Longitude: -80.156314

For data sources see[1][2][3]

Well History

Date Event
2013-11-22 New Permit Application
2014-04-26 Performed Spud Operation
2014-08-26 Drilling Completion
2014-12-02 Perforation
2014-12-02 Performed Stimulation
2016-07-05 Deviated

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2015-01-02 2015-01-27 8,087 8,917,000

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Base Fluid Chevron Carrier/Base Fluid Water (Including Mix Water Supplied by Client) 7732-18-5 100 88.6801 0
EC6116A Nalco Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30 0.00073826 0
Polyethylene Glycol 25322-68-3 60 0.00147653 0
Dibromoacetonitrile 3252-43-5 5 0.00012304 0
Proppant Schlumberger Proppant Crystalline Silica 14808-60-7 100 11.1238 0
J134 Schlumberger Gel Breaker Hemicellulase enzyme 9012-54-8 100 0.00179585 0
A264 Schlumberger Corrosion Inhibitor Aliphatic alcohols, ethoxylayed #1 Proprietary 30 0.00003784 0
Methanol 67-56-1 40 0.00005045 0
Aliphatic acids Proprietary 30 0.00003784 0
Prop-2-yn-1-ol 107-19-7 10 0.00001261 0
B466 Schlumberger Friction Reducer Alcohol Ethoxylates Proprietary 5 0.00059173 0
Distillates (petroleum), hydrotreated light 64742-47-8 30 0.00355039 0
Ammonium Acetate 631-61-8 6 0.00071008 0
15% Acid Schlumberger Perf Cleanup Hydrocloric Acid 7647-01-0 15 0.011284 0
L058 Schlumberger Iron Stabilizer Sodium erythorbate 6381-77-7 100 0.00067812 0
EC6486A Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00079152 0
EC6673W Nalco Iron Control Ethylene Glycol 107-21-1 30 0.00074205 0
J580 Schlumberger Gelling Agent, Water Carbohydrate Polymer Proprietary 100 0.0320319 0

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-12-02 1,981,457 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 1,207,515.00 198 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 1,271,828.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 824,927.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 566,167.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 451,328.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 742.60 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Drill Cuttings 628.57 Tons LANDFILL 100419
2014 CHEVRON APPALACHIA LLC Drilling Fluid Waste 1,444.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Drilling Fluid Waste 84.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Drill Cuttings 8.77 Tons LANDFILL 100592
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 396.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Drill Cuttings 310.60 Tons LANDFILL 100172
2015 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 24.90 Tons LANDFILL 100172
2015 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 0.77 Tons LANDFILL 100277
2015 CHEVRON APPALACHIA LLC Produced Fluid 59.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 8.86 Tons LANDFILL 100592
2015 CHEVRON APPALACHIA LLC Drill Cuttings 1.24 Tons LANDFILL 100663
2015 CHEVRON APPALACHIA LLC Fracing Fluid Waste 2,321.80 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 18.69 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2015 CHEVRON APPALACHIA LLC Fracing Fluid Waste 8,696.20 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Produced Fluid 14,023.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Soil Contaminated by Oil & Gas Related Spills 0.15 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2016 CHEVRON APPALACHIA LLC Produced Fluid 4,074.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid 7,729.10 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Produced Fluid 841.99 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Produced Fluid 97.40 Bbl INJECTION DISPOSAL WELL 34-059-24202
2017 CHEVRON APPALACHIA LLC Produced Fluid 1,587.37 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 54.83 Bbl INJECTION DISPOSAL WELL 34-119-28776
2017 CHEVRON APPALACHIA LLC Produced Fluid 1,616.20 Bbl INJECTION DISPOSAL WELL 34-157-25511
2017 CHEVRON APPALACHIA LLC Produced Fluid 16,311.00 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 504.80 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 154.07 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Other Oil & Gas Wastes 0.20 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 CHEVRON APPALACHIA LLC Produced Fluid 2,755.20 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 CHEVRON APPALACHIA LLC Produced Fluid 469.64 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 1,652.00 Bbl REUSE (AT WELL PAD)
2019 CHEVRON APPALACHIA LLC Produced Fluid 26.34 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 CHEVRON APPALACHIA LLC Produced Fluid 26.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 238.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2280572 Primary Facility 2014-06-06 Drilling/Alteration No Violations Noted spud on 6/5/14; Drilling @ 410'; no pad issues; no containment concerns;
2280607 Primary Facility 2014-06-12 Drilling/Alteration No Violations Noted Spud 6/5/14 by Yost 5 rig for Chevron; Drill to 550'; set 16"@ 520'; cement to surface with 25 bbls of returns; drill to 1026'; Set 11 3/4"casing@ 977'; Basket @ 903'; open mine @923'; cement at bottom and ran 615 sks down annulus with no returns; ran out of cemnt; will complete annuluar cementing after running 16" on upcoming 2H well;
2280619 Primary Facility 2014-06-20 Drilling/Alteration No Violations Noted Cemented back annulus 20 bbls of return;
2296955 Primary Facility 2014-08-19 Drilling/Alteration No Violations Noted Nabors X-09 spud on 8/15/14; TD on 8/19 @ 2621'; Set 8 5/8" casing @ 2579'; Cement with Type 1; 131.4 bbls; 15 bbls of cement returns; plug down 08:37 8/19/14;
2298793 Primary Facility 2014-07-14 Routine/Complete Inspection No Violations Noted Well in compliance.
2300125 Primary Facility 2014-08-26 Drilling/Alteration No Violations Noted Nabors X-09 rig drlling @ 12014'; No drilling issues; Containment to be vacuumed as per site inspection PDQ;
2329979 Primary Facility 2014-12-10 Routine/Complete Inspection No Violations Noted
2331552 Primary Facility 2014-12-23 Complaint Inspection No Violations Noted Frac job underway.
2379379 Primary Facility 2015-03-31 Routine/Complete Inspection No Violations Noted Well drilled fracked. Operations on going to place well into production.
2398585 Primary Facility 2015-07-07 Routine/Complete Inspection No Violations Noted
2530854 Primary Facility 2016-10-07 Site Restoration No Violations Noted An inspection conducted in response to a notice of termination request by the operator.
2570924 Primary Facility 2017-03-13 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was partially snow-covered but appeared to be well vegetated. There were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2598323 Primary Facility 2017-05-08 Routine/Complete Inspection No Violations Noted An inspection was conducted in response to a well site restoration report being submitted by Chevron. The Act 9 sign was in place and all required documents were present at the site. The site was found to be restored and well vegetated. There were no violations observed at the time of inspection.
2630375 Primary Facility 2017-07-27 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. At Chevron's request, Department Water Quality and Oil and Gas Inspector staff met with Chevron representatives to demonstrate a site inspection. The site was well vegetated and there were no signs of erosion observed at the time of inspection. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2670277 Primary Facility 2017-12-11 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2786605 Primary Facility 2018-10-10 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.

For data sources see[9]

References