If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-059-26702 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.931881,"lon":-80.256381,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Greene | |
Municipality: Morris Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 152021 | |
Farm/Lease Name: HARDEN FARMS | |
License Status: Active | |
Spud Date: 2015-07-07 | |
Permit Date: 2014-11-14 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 39.931881 | |
Longitude: -80.256381 |
Date | Event |
---|---|
2014-11-14 | New Permit Application |
2015-07-07 | Performed Spud Operation |
2016-01-27 | New Permit Application |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2016-01-14 | 2016-01-27 | 7,809 | 7,448,830 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | FRW-900 | FTS International | Friction Reducer | Oxyalkylated Alcohol A | Proprietary | 5 | 0.000478504 | 339.737 |
Alkyl Alcohol | Proprietary | 10 | 0.000957009 | 679.475 | ||||
Hydrotreated Light Distillate | 64742-47-8 | 30 | 0.00287103 | 2038.43 | ||||
MC MX 5-3886 | Multi-Chem Group | Specialty Brine | Calcium Nitrate.4H2O | 13477-34-4 | 100 | 0.107793 | 76533.1 | |
CS-500 SI | FTS International | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 10 | 0.00244245 | 1734.13 | |
MC MX 5-2349 | Multi-Chem Group | Friction Reducer Breaker | Ethylene Glycol | 107-21-1 | 13 | 0.00002448 | 17.383 | |
Ammonium persulfate | 7727-54-0 | 13 | 0.00002448 | 17.383 | ||||
Water | FTS International | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 87.5501 | 62,160,500.0 | |
LD-2550 | Multi-Chem Group | Additive | Inner salt of alkyl amines | Proprietary | 60 | 0.00739765 | 5252.32 | |
Sodium chloride | 7647-14-5 | 10 | 0.00123294 | 875.387 | ||||
Cl-150 | FTS International | Acid Corrosion Inhibitor | Organic amine resin salt | Proprietary | 30 | 0.000122178 | 86.746 | |
Isopropanol | 67-63-0 | 30 | 0.000122178 | 86.746 | ||||
Dimethylformamide | 68-12-2 | 10 | 0.00004073 | 28.915 | ||||
Ethylene Glycol | 107-21-1 | 30 | 0.000122178 | 86.746 | ||||
Aromatic aldehyde | Proprietary | 10 | 0.00004073 | 28.915 | ||||
Quaternary ammonium compound | Proprietary | 10 | 0.00004073 | 28.915 | ||||
Sand (Proppant) | FTS International | Proppant | Silica Substrate | 14808-60-7 | 100 | 11.9572 | 8,489,570.0 | |
Hydrochloric Acid (15%) | FTS International | Acidizing | Hydrochloric Acid | 7647-01-0 | 15 | 0.0452747 | 32144.9 | |
LD-2250 | Multi-Chem Group | Friction Reducer | Hydrotreated light petroleum distillate | 64742-47-8 | 30 | 0.0108498 | 7703.32 | |
Sodium chloride | 7647-14-5 | 5 | 0.0018083 | 1283.89 | ||||
Ethoxylated alcohol | Proprietary | 5 | 0.0018083 | 1283.89 | ||||
Fatty nitrogen derived amides | Proprietary | 5 | 0.0018083 | 1283.89 | ||||
Polyacrylate | Proprietary | 30 | 0.0108498 | 7703.32 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2015 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | EQT PROD CO | 2,169,433.00 | 262 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 1,166,549.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 283,373.00 | 220 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 194,756.00 | 79 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2015 | EQT PROD CO | Fracing Fluid Waste | 545.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Drilling Fluid Waste | 2,200.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Drill Cuttings | 1,257.94 Tons | LANDFILL | 100419 |
2016 | EQT PROD CO | Other Oil & Gas Wastes | 2.96 Tons | LANDFILL | 100419 |
2016 | EQT PROD CO | Servicing Fluid | 25.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Drilling Fluid Waste | 2,000.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Other Oil & Gas Wastes | 434.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid | 29,124.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid | 444.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2016 | EQT PROD CO | Synthetic Liner Materials | 4.57 Tons | LANDFILL | 100419 |
2016 | EQT PROD CO | Produced Fluid | 1,175.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 120.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Produced Fluid | 3,625.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Produced Fluid | 120.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 124.61 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Produced Fluid | 140.54 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Produced Fluid | 187.60 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 181.78 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Produced Fluid | 0.01 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 60.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 10.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 535.68 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2389992 | Primary Facility | 2015-07-08 | Drilling/Alteration | No Violations Noted | Well spud on 7/7/2015. Operator drilled 24-inch borehole and set 20-inch conductor pipe at 40 ft. Conductor pipe cemented in place. NOVIO |
2400581 | Primary Facility | 2015-08-04 | Drilling/Alteration | No Violations Noted | Alpha Hunter 8 Drilling Rig. Surface casing (13 3/8”) set and cemented @ 1145’ on 8/3/15. Drill site manager reported no cementing issues. |
2400596 | Primary Facility | 2015-08-07 | Drilling/Alteration | No Violations Noted | Alpha Hunter 8 Drilling Rig. Intermediate casing (9 5/8”) set and cemented @ 3161’ on 8/7/15. Drill site manager reported no cementing issues. Borehole drilled to 3210’. Preparing to skid rig to next well location. |
2409097 | Primary Facility | 2015-09-15 | Drilling/Alteration | No Violations Noted | Orion Rig 17. Drilling ahead in sidetrack @ 11,285’. Operator sidetracked after 5 ½” production casing became stuck during installation @ 11,773’ in the original borehole. Operator cut casing @ 6,800’ and set isolation and kick off cement plugs from 6,793’-6,193’ and 6,159’-5,538’. |
2409111 | Primary Facility | 2015-09-04 | Drilling/Alteration | No Violations Noted | Orion Rig 17. Resumed drilling @ 5,298’ on 8/31/2015. Currently drilling in the curve @ 7,789’. |
2410033 | Primary Facility | 2015-06-12 | Routine/Complete Inspection | No Violations Noted | Well not drilled. Pre-spud inspection |
2617372 | Primary Facility | 2017-07-20 | Routine/Complete Inspection | No Violations Noted | On Thursday, July 20, 2017, I conducted a routine-complete inspection of the Harden Farms Well Site located in Morris Township, Greene County.
The Act 9 site ID sign was in place and clearly legible at the site entrance and all required documentation was available on-site. The access road and the well pad were in good condition and the site is stabilized with perennial vegetative growth. Some lighter growth was observed around the impoundment although according to the plans, more work will be conducted in this area in the future. Some filter sock was observed in various places around the site. The operator might consider re-evaluating the vegetative growth in the various areas to determine whether the filter sock should be removed or not. The secondary containment structure around the production tanks appears to be in good condition and functioning as intended. The gas wells appear to be in good working order and are each labelled as required. No violations were identified during the inspection. |
2632936 | Primary Facility | 2017-09-06 | Routine/Complete Inspection | No Violations Noted | Well is properly identified and is equipped for production. Well is equipped with sand buster, production unit, and 400 bbl production tank. Production tank is located in diked area. 100 bbl sand buster/trap tank also on location. |
2720278 | Primary Facility | 2018-04-19 | Routine/Complete Inspection | No Violations Noted | The Department is unable to observe the wellhead. The well is located below grade in a well cellar covered by a steel plate. The well is producing.
The operator has spud three new wells on site. The operator was installing well cellars at the time of the inspection. |
For data sources see[8]