37-059-27617

Well Details

Well ID: 37-059-27617
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Washington Township
Operator Name: EQT PROD CO
Well Pad ID: 145801
Farm/Lease Name: SHIPMAN WAY90H13
License Status:
Spud Date:
Permit Date: 2018-01-26
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 39.987417
Longitude: -80.186447

For data sources see[1][2][3]

Well History

Date Event
2018-01-26 New Permit Application
2018-02-07 Performed Spud Operation
2019-01-07 Permit Renewal Application

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2019 EQT PROD CO 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2018 EQT PROD CO Synthetic Liner Materials 15.29 Tons LANDFILL 100419
2018 EQT PROD CO Other Oil & Gas Wastes 2.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 562.51 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Other Oil & Gas Wastes 7.86 Bbl INJECTION DISPOSAL WELL 34-105-23619
2019 EQT PROD CO Other Oil & Gas Wastes 9.29 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Other Oil & Gas Wastes 8.57 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Other Oil & Gas Wastes 826.92 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2696703 Primary Facility 2018-02-16 Drilling/Alteration No Violations Noted After Cellar Tech installs cellar , 26" conductor set at 52'.
2809943 Primary Facility 2018-11-26 Incident- Response to Accident or Event In Compliance with Policy On 11/22/18 at approximately 0952 David Guidas of EQT reported an impaired water spill on the Shipman well pad.

On 11/26/18 at approximately 1200 hours I conducted an incident response inspection. I spoke via phone with David Guidas who indicated 10 gallons of produced fluid was spilled when a line containing impaired water was removed from a frac tank. Due to teardown activities at the site the secondary containment had a hole that allowed the fluid to reach the ground surface. The spill was remediated by SPSI. The spill has been addressed in compliance with DEP spill policy.

2821258 Primary Facility 2019-01-02 Routine/Complete Inspection No Violations Noted On site inspection was unable to open plate over cellar. Phone call with Bruce Gallick confirmed no conductor had been set. Inspection record #2696703 was incorrectly filed on 2/16/18. On site inspection showed no apparent violations. NOVIO

For data sources see[7]

References