37-063-37308

Well Details

Well ID: 37-063-37308
Loading map...
Country: United States
State: Pennsylvania
County: Indiana
Municipality: North Mahoning Township
Operator Name: XTO ENERGY INC
Well Pad ID: 147685
Farm/Lease Name: A K STEAR A UNIT 1H
License Status:
Spud Date: 2012-05-24
Permit Date: 2012-01-04
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.860836
Longitude: -79.078464

For data sources see[1][2][3]

Well History

Date Event
2012-01-04 New Permit Application
2012-05-22 Performed Spud Operation
2012-07-09 Drilling Completion
2012-08-16 Perforation
2013-01-15 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-10-18 2012-10-18 7,274 4,893,933

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Water 7732-18-5 100.00 87.89
Sand Proppant Quartz 14808-60-7 100.00 11.12
Acid - 7.5 HCl Acid PPG Industries Acid
Hydrochloric acid 7647-01-0 7.50 0.02
Other -(non hazardous) 92.50 0.36
Acid Corrosion Inhibitor - EcoAcid CI Geosafe Chemicals Corrosion Inhibitor
Diethylene glycol monobutyl ether 112-34-5 50.00 0.00042000
Other -(non hazardous) 50.00 0.00042000
Scale Inhibitor - MC-MX-588-2 Multi-Chem Group Scale Inhibitor Other -(non hazardous) 100.00 0.02
Biocide - MC 8650 Multi-Chem Group Biocide
Other -(non hazardous) 40.00 0.00210000
Glutaraldehyde 111-30-8 60.00 0.00320000
Friction Reducer - MC MX-14-5 Multi-Chem Group Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.01
Other -(non hazardous) 70.00 0.03
Acid - 15 HCl Acid PPG Industries Acid
Hydrochloric acid 7647-01-0 15.00 0.07
Other -(non hazardous) 85.00 0.41
Biocide - MC 8520 Multi-Chem Group Biocide
4,4-Dimethyloxazolidine 51200-87-4 95.00 0.01
3,4,4-Trimethyloxazolidine 75673-43-7 4.50 0.00054000
2-Amino-2-methylpropan-1-ol 124-68-5 0.50 0.00006000
Clay Stabilizer - ClaChek G (Bio-Add 1200) Shrieve Clay Stabilizer Not hazardous 70.00 0.01
Water 7732-18-5 30.00 0.00218000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 XTO ENERGY INC 0.00 0 0.00 0 0.00 0
2013 XTO ENERGY INC 583,425.00 364 0.00 0 0.00 0
2014 XTO ENERGY INC 446,343.00 365 0.00 0 0.00 0
2015 XTO ENERGY INC 323,787.00 365 0.00 0 0.00 0
2016 XTO ENERGY INC 252,608.00 362 0.00 0 0.00 0
2017 XTO ENERGY INC 212,500.00 364 0.00 0 0.00 0
2018 XTO ENERGY INC 210,281.84 365 0.00 0 0.00 0
2019 XTO ENERGY INC 182,672.76 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 XTO ENERGY INC Drill Cuttings 777.75 Tons LANDFILL 101397
2012 XTO ENERGY INC Drill Cuttings 359.95 Tons LANDFILL 100434
2013 XTO ENERGY INC Fracing Fluid Waste 270.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 101674
2013 XTO ENERGY INC Produced Fluid 5,698.00 Bbl RESIDUAL WASTE TRANSFER FACILITY 101674
2013 XTO ENERGY INC Produced Fluid 345.00 Bbl INJECTION DISPOSAL WELL 34-059-24067
2013 XTO ENERGY INC Fracing Fluid Waste 65.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 XTO ENERGY INC Produced Fluid 100.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW009
2013 XTO ENERGY INC Produced Fluid 1,665.00 Bbl CENT WASTE TRT FAC NPDES PA0254185
2013 XTO ENERGY INC Fracturing Fluid Waste 187.67 Tons LANDFILL 100434
2013 XTO ENERGY INC Produced Fluid 1,665.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0254185
2013 XTO ENERGY INC Fracing Fluid Waste 366.00 Bbl INJECTION DISPOSAL WELL 34-133-24189
2014 XTO ENERGY INC Produced Fluid 713.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2014 XTO ENERGY INC Produced Fluid 5,192.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW009
2014 XTO ENERGY INC Produced Fluid 200.00 Bbl CENT WASTE TRT FAC NPDES PA0254185
2014 XTO ENERGY INC Produced Fluid 200.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0254185
2015 XTO ENERGY INC Produced Fluid 100.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015 XTO ENERGY INC Produced Fluid 3,690.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW009
2016 XTO ENERGY INC Produced Fluid 1,233.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW009
2016 XTO ENERGY INC Produced Fluid 35.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 XTO ENERGY INC Produced Fluid 975.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2017 XTO ENERGY INC Produced Fluid 180.00 Bbl REUSE (AT WELL PAD)
2017 XTO ENERGY INC Produced Fluid 1,552.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 XTO ENERGY INC Produced Fluid 203.00 Bbl REUSE (AT WELL PAD)
2018 XTO ENERGY INC Produced Fluid 80.00 Bbl INJECTION DISPOSAL WELL 34-133-24096
2018 XTO ENERGY INC Produced Fluid 1,888.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 XTO ENERGY INC Produced Fluid 105.83 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 XTO ENERGY INC Produced Fluid 93.00 Bbl INJECTION DISPOSAL WELL 34-133-24189
2019 XTO ENERGY INC Produced Fluid 877.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 XTO ENERGY INC Produced Fluid 93.00 Bbl INJECTION DISPOSAL WELL 34-133-21076
2019 XTO ENERGY INC Produced Fluid 100.00 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2064199 Primary Facility 2012-05-01 Routine/Complete Inspection In Compliance with Policy Pre-construction meeting, for multi-well pad, with XTO Reps Dan Rice (Construction) and Tom Burnett (EHS) and First Class Energy (Construction Contractor). Well permit issued 1/4/12. Proper signage and ES plans located onsite. Reviewed ES plans and construction sequence with individual’s onsite.
2071248 Primary Facility 2012-05-25 Drilling/Alteration No Violations Noted
2073673 Primary Facility 2012-06-05 Routine/Complete Inspection No Violations Noted During this inspection, XTO rep Tom Baun and First Class Energy Rep( Construction Contractor) present. Site ID sign, ES plan, ESCGP-1 located onsite. Rig currently tore down, it is believed top hole drilled. Spud 5/22/12. minor changes have been noted on ES plan, the addition of a rock lined culvert along access road to well site and removal of culvert (per Penn Dot due to drainage on SR 410). Previously disturbed areas covered with matting and seeded/mulched with observed growth not quit 70% uniform coverage. Pad adequately rocked. No accelerated E&S issues on well pad. Temporary containment located onsite beneath former location of rig, appears sound. XTO reps and myself examined access road leading to a impoundment, not yet constructed. A culvert was installed and a sediment basin, it appears that due to grade and recent heavy rains the sediment basin could not handle flow; therefore, XTO would like to install a water bar leading to culvert located down gradient near well pad entrance. Dept ok'ed no increase in acerage or distrubed area-
2081473 Primary Facility 2012-07-06 Drilling/Alteration No Violations Noted
2086444 Primary Facility 2012-07-17 Drilling/Alteration No Violations Noted
2089278 Primary Facility 2012-07-31 Drilling/Alteration No Violations Noted
2092834 Primary Facility 2012-08-16 Routine/Complete Inspection No Violations Noted *Well site located within special protection water*
2092962 Primary Facility 2012-08-18 Drilling/Alteration No Violations Noted
2101744 Primary Facility 2012-09-20 Drilling/Alteration No Violations Noted
2108412 Primary Facility 2012-10-15 Routine/Complete Inspection No Violations Noted At the time of this inspection wells actively being fraced. Bmp's installed and maintained, noaccelerated erosion or sedimentation concerns noted on access road or well site. Hence well site is located with HQ waters, department reiterated to operator that deflectors are not considered ABACT bmp's and in order to sustain sufficient sediment removal an additoinal ABACT bmp is reccomended, department referred operator to currentl ES manual for list of acceptable ABACT bmp's. Operator agreed to install water delfector in access road, as well as add additional compost sox in order to increase the effiencety of sediment removal. Based on this inspection, if operator installs/maintains additonal bmp's as outlined in ES manual and revised plans department shall ok minor changes as noted.
2109417 Primary Facility 2012-10-18 Drilling/Alteration No Violations Noted
2128914 Primary Facility 2013-01-08 Routine/Complete Inspection No Violations Noted Access road entrance adequately rocked, although due to recent thaw and contiual traffic on/off site is reccomended that operator closely monitor and maintain access roadway as needed to ensure that mud does not exit the well site onto SR 210. Well drillled and equipped for prodcution. Well head surrounded by wire fence, recommend operator install a visible, permanent well tag on well head as per regulation. Prodcution equipment contained with in a metal containment unit. Brine tank appears sound. No evidence of Industrail waste concerns. Site snow covered; therefore, unable to adequately assess temporary stablization measures and temporary bmp functioning capacity. Although no accelerated erosion or sedimeantion issues observed. Department recommends that operator install a temp bmp beneath soil pile located on back side of well pad in order to prevent a potentail pollution event as a result of recent thaw, piles appears to be frozen. No violations noted at time of this inspection
2137936 Primary Facility 2013-02-07 Routine/Complete Inspection No Violations Noted
2168010 Primary Facility 2013-05-03 Routine/Complete Inspection No Violations Noted Inspt in response to restoration extension request.
2222610 Primary Facility 2013-11-18 Routine/Complete Inspection No Violations Noted At time of inspection, well equipped for production. Spud date was 5/22/2012. Wellhead surrounded by chain-link fence and cement barriers. Well tag present, legible.
2248812 Primary Facility 2014-02-26 Routine/Partial Inspection No Violations Noted RTPT. At time of inspection, well equipped for production. According to records, drilling occurred 5/24/2012-7/8/2012. Wellhead surrounded by chain-link fence and cement barriers. Well tag present, legible.
2320022 Primary Facility 2014-11-04 Routine/Complete Inspection No Violations Noted Marcellus.Well drilled and equipped for production.Drilling occurred 5/24/2012-7/8/2012.Wellhead surrounded by chain-link fence and cement barriers.WT present, legible.One BT appears sound, located in lined secondary metal containment unit with gravel base.Site ID sign present, in compliance with Act 9 standards.Permit numbers posted.ERP, PPCP, E&S/PCSM plans, ESCGP-1 present at AR entrance.AR in good condition, entrance paved as per E&S plan.Pad stable.Well site stabilized with uniform and adequate vegetative growth.BMPs appear maintained and functioning properly.No accelerated E&S issues noted in relation to well site.Dept recommends Opr install additional rock and/or another alternative stabilization measure at outlet of first water deflector/inlet of second AR culvert as entering well site, continue to monitor and maintain BMPs, and remove any posted permit signs for any permits which have expired.Extension for site restoration previously granted until April 8, 2015 (inspection record 2168010).
2370272 Primary Facility 2015-05-06 Site Restoration Violation(s) Noted Marcellus.At time of inspt, well drilled,appears equipped for production.Drilling occurred 5/24/12-7/8/12.WH surrounded by chain-link fence,cement barriers.WT present, legible.BT located in lined secondary metal containment unit,gravel base,appears sound.Site ID sign present, in compliance with Act 9.ERP, PPCP, E&S/PCSM plans, ESCGP-1 on-site.Dept recom’ds Opr install add’l rock and/or another alternative stabilization measure at outlet of first water deflector/inlet of second AR culvert as entering well site, continue to monitor/maintain all BMPs, and re-seed/mulch fill slopes to ensure permanent stabilization is maintained.Extension for site restoration previously granted until 4/8/15 (inspection record 2168010).Appears infiltration berm recently installed and/or maintained.At this time, areas surrounding infiltration berm not yet exhibiting >70% uniform and adequate veg growth.Temp BMPs installed down-gradient of infiltration berm.As site is not yet restored as per current regs, viols issued under 3216 & 102.22 for failure to restore well site.
2394752 Primary Facility 2015-07-27 Compliance Evaluation No Violations Noted On-site CEI conducted in response to violations issued under inspection record 2370272 (enf ID 323276) for failure to restore well site.
2395452 Primary Facility 2015-07-27 Site Restoration No Violations Noted Restr inspt.Marcellus.At time of inspt, well drilled and appears equipped for production.According to records, drilling occurred 5/24/2012-7/8/2012.Wellhead surrounded by chain-link fence and cement barriers.WT present, legible.BT located in lined secondary metal containment unit with gravel base, appears sound.Site ID sign present, in compliance with Act 9 standards.Permit numbers posted. ERP, PPCP, MSDS sheets, E&S/PCSM plans, ESCGP-1 present at AR entrance.AR in good condition, entrance paved as per E&S plan.Pad stabilized with gravel.Extension for site restoration previously granted until April 8, 2015 (inspection record 2168010).At this time, well site is permanently stabilized with >70% uniform and adequate vegetative growth.PCSM BMPs appear implemented per PCSM plan.Final restoration achieved.Dept recommends Opr cont’ to monitor and maintain all PCSM BMPs, well site, and access road as necessary in order to prevent any potential pollution events from occurring.
2484886 Primary Facility 2016-05-16 Routine/Complete Inspection No Violations Noted 5/16/2016 - Annulus closed, produced fluids tank diked..
2683575 Primary Facility 2018-01-18 Routine/Partial Inspection No Violations Noted At time of inspection, well drilled and appears equipped for production.
2826152 Primary Facility 2019-01-11 Routine/Complete Inspection No Violations Noted On 1/11/19 at 0858 hrs., I conducted a routine inspection of XTO Energy, Inc.'s A. K. Stear A Unit 1H well (API 063-37308) in North Mahoning Twp., Indiana Co. Snow cover prevented proper evaluation of site stabilization. The pad appears to be restored and permanently stabilized. The well is properly labeled and equipped for production. A well tag is present at the well head. Site Id signs and necessary permits are posted at the site entrance. The production fluid tank is located within adequate secondary containment. There are no violations noted for this inspection.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2370272 722948 05/06/2015 2015-05-06 OGA3216(A) - WELL SITE RESTORATIONS - GENERAL RULE - Failure to restore disturbed land surface of a well site. Environmental Health & Safety
2370272 722957 05/06/2015 2015-05-06 102.22(a) - Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
722948 323276 NOV - Notice of Violation Comply/Closed 2015-07-07

For data sources see[8]

References