If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-20144 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.272219,"lon":-76.636656,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Penn Township | |
Operator Name: EXCO RESOURCES PA LLC | |
Well Pad ID: 148314 | |
Farm/Lease Name: FALK UNIT 1H | |
License Status: | |
Spud Date: | |
Permit Date: 2009-03-19 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.272219 | |
Longitude: -76.636656 |
Date | Event |
---|---|
2009-03-19 | New Permit Application |
2009-07-09 | Performed Spud Operation |
2009-09-29 | Drilling Completion |
2010-03-10 | DEVIATED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2009 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | CHIEF OIL & GAS LLC | 704,091.50 | 163 | 0.00 | 0 | 0.00 | 0 |
2011 | EXCO RESOURCES PA LLC | 883,635.00 | 305 | 0.00 | 0 | 0.00 | 0 |
2012 | EXCO RESOURCES PA LLC | 953,539.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2013 | EXCO RESOURCES PA LLC | 693,082.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | EXCO RESOURCES PA LLC | 466,027.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | EXCO RESOURCES PA LLC | 361,946.00 | 311 | 0.00 | 0 | 0.00 | 0 |
2016 | EXCO RESOURCES PA LLC | 286,441.00 | 280 | 0.00 | 0 | 0.00 | 0 |
2017 | EXCO RESOURCES PA LLC | 304,766.00 | 337 | 0.00 | 0 | 0.00 | 0 |
2018 | EXCO RESOURCES PA LLC | 286,496.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2019 | EXCO RESOURCES PA LLC | 207,834.00 | 363 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | CHIEF OIL & GAS LLC | Produced Fluid | 650.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2010 | CHIEF OIL & GAS LLC | Produced Fluid | 130.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2010 | CHIEF OIL & GAS LLC | Drilling Fluid Waste | 2,468.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2010 | CHIEF OIL & GAS LLC | Produced Fluid | 5,787.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW018 |
2010 | CHIEF OIL & GAS LLC | Produced Fluid | 420.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2010 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 4,172.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2010 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 3,204.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0027057 |
2010 | CHIEF OIL & GAS LLC | Produced Fluid | 315.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2010 | CHIEF OIL & GAS LLC | Drilling Fluid Waste | 4,803.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2011 | EXCO RESOURCES PA LLC | Drilling Fluid Waste | 770.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2011 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 110.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2011 | CHIEF OIL & GAS LLC | Produced Fluid | 5,609.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2011 | EXCO RESOURCES PA LLC | Produced Fluid | 823.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | EXCO RESOURCES PA LLC | Produced Fluid | 178.50 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2011 | EXCO RESOURCES PA LLC | Produced Fluid | 416.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PAS2D205BCLE |
2011 | EXCO RESOURCES PA LLC | Produced Fluid | 476.00 Bbl | INJECTION DISPOSAL WELL | PAS2D902BCLE |
2011 | EXCO RESOURCES PA LLC | Produced Fluid | 2,559.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2011 | EXCO RESOURCES PA LLC | Produced Fluid | 1,904.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2012 | EXCO RESOURCES PA LLC | Produced Fluid | 3,151.87 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2012 | EXCO RESOURCES PA LLC | Produced Fluid | 28.57 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | EXCO RESOURCES PA LLC | Drill Cuttings | 39.25 Tons | LANDFILL | 301358 |
2012 | EXCO RESOURCES PA LLC | Fracturing Fluid Waste | 407.67 Tons | LANDFILL | 301358 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 1,071.16 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 78.57 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC009 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 1,190.43 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 87.60 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC024 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 404.84 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 121.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 331.40 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 646.60 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 219.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC024 |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 705.90 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 141.40 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 33.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | EXCO RESOURCES PA LLC | Produced Fluid | 36.30 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC009 |
2015 | EXCO RESOURCES PA LLC | Produced Fluid | 1,004.90 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2015 | EXCO RESOURCES PA LLC | Produced Fluid | 11.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EXCO RESOURCES PA LLC | Produced Fluid | 1,207.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2017 | EXCO RESOURCES PA LLC | Produced Fluid | 688.10 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2018 | EXCO RESOURCES PA LLC | Produced Fluid | 75.80 Bbl | REUSE (AT WELL PAD) | |
2018 | EXCO RESOURCES PA LLC | Produced Fluid | 1,169.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2018 | EXCO RESOURCES PA LLC | Produced Fluid | 146.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2019 | EXCO RESOURCES PA LLC | Produced Fluid | 515.40 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2019 | EXCO RESOURCES PA LLC | Produced Fluid | 129.40 Bbl | REUSE (AT WELL PAD) |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1816410 | Primary Facility | 2009-07-27 | Routine/Complete Inspection | No Violations Noted | Charles Construction Company was in the process of constructing the well pad during the inspection. Keith of Charles Construction provided me with a copy of the E&S plan and indicated that they have been working on the pad for approximately one week. No violations were noted during this inspection. I will schedule to reinspect as construction progresses or whenever the pad is complete. |
1820540 | Primary Facility | 2009-08-11 | Routine/Complete Inspection | Violation(s) Noted | Failure to implement and maintain BMPs, plan inadequate, sedimentation of vernal pool / wetland area and unauthorized minor and major modifications of ESCGP. See Insp ID 1829756 conducted 9/22/09, past violations corrected. MBC 9/23/09 |
1824525 | Primary Facility | 2009-08-27 | Compliance Evaluation | Outstanding Violations - No Viols Req'd | See Insp ID 1829756 conducted 9/22/09, past violations corrected. MBC 9/23/09 |
1825921 | Primary Facility | 2009-09-04 | Compliance Evaluation | Violation(s) Noted | Fill installed in a wetland without a permit or a waiver. See Insp ID 1829756 conducted 9/22/09, past violations corrected. MBC 9/23/09 |
1827401 | Primary Facility | 2009-09-11 | Routine/Complete Inspection | No Violations Noted | On site meeting with the Army Corps and Chief to discuss resolving the wetland encroachment. |
1829756 | Primary Facility | 2009-09-22 | Compliance Evaluation | No Violations Noted | This inspection has revealed that the former wetland encroachment and E&S violations can be resolved at this time. Past violations corrected. MBC 9/23/09 |
1832331 | Primary Facility | 2009-09-14 | Drilling/Alteration | No Violations Noted | told udi man about keeping drillers log gave him 2 copies and he said it would be done... rig at 3116 ft deep tripping out of hole bit trip. |
1861490 | Primary Facility | 2010-01-27 | Drilling/Alteration | Violation(s) Noted | work over rig on location drilling cement out of inside of casing. hit cement at 301 ft deep. they never notified dept of cement job or their plans on how they were going to fix it. |
1862354 | Primary Facility | 2010-02-11 | Routine/Complete Inspection | No Violations Noted | |
1865829 | Primary Facility | 2010-01-27 | Drilling/Alteration | Violation(s) Noted | |
1865832 | Primary Facility | 2010-02-16 | Drilling/Alteration | No Violations Noted | work over rig @4622 ft deep still drilling cement out of casing also installing 5000lb blow out preventer on well |
1865862 | Primary Facility | 2010-02-25 | Drilling/Alteration | No Violations Noted | work over rig done with drilling cement out of 5 1/2 in casing allied to be on location later to do pressure test on casing. no plan has been somitted to dep on plan to fix inadquate cement job yet |
1899634 | Primary Facility | 2010-07-21 | Routine/Partial Inspection | Violation(s) Noted | No well tag, cuttings on ground, pollutional substances in cellar, pit has holes in liner and lacks required 2' freeboard |
1929487 | Primary Facility | 2010-11-15 | Follow-up Inspection | No Violations Noted | |
1942089 | Primary Facility | 2011-01-06 | Routine/Complete Inspection | No Violations Noted | |
1965773 | Primary Facility | 2011-04-13 | Routine/Complete Inspection | No Violations Noted | |
2051023 | Primary Facility | 2012-03-15 | Routine/Complete Inspection | Violation(s) Noted | went to see if prod. water from Houseknecht transfered to Falk then Kensinger. Found prod. water spills. |
2056683 | Primary Facility | 2012-04-02 | Routine/Partial Inspection | Outstanding Violations - No Viols Req'd | |
2069506 | Primary Facility | 2012-05-18 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | |
2072678 | Primary Facility | 2012-06-01 | Drilling/Alteration | No Violations Noted | |
2076721 | Primary Facility | 2012-06-12 | Routine/Complete Inspection | No Violations Noted | |
2092491 | Primary Facility | 2012-08-15 | Routine/Complete Inspection | No Violations Noted | |
2100910 | Primary Facility | 2012-09-13 | Routine/Complete Inspection | No Violations Noted | |
2436748 | Primary Facility | 2015-12-30 | Routine/Complete Inspection | No Violations Noted | Arrived @ 11:40. Weather: foggy, cloudy, some fine drizzle. Five wells, formerly in production, were shut-in. Lease tender Bobby Hamel was onsite pumping rain water out of the containment around the produced water tank. All well cellars were filled with gravel. There were two open annular vents at each well. The 13-3/8” x 9-5/8” was vented with a 1” pipe. The 9-5/8” x 5-1/2” annulus was vented with a 2” pipe. The annuli were monitored with an Altair 5X gas meter calibrated on 12/28/15. |
2543930 | Primary Facility | 2016-12-08 | Routine/Complete Inspection | No Violations Noted | Routine Inspection; 12/8/2016. I entered the location at 10:06 and began the inspection. At the time of the inspection, the Falk Unit 1H (081-20144), 2H (081-20180), 3H (081-20205), 4H (20209) and 5H(081-20210)wells were in production. The well pad area was relatively well vegetated but some erosion was noted along the access road and one of the basins onsite was had a fair amount of standing water. The well site has not been restored and the Well Site Compliance Information Request reply (submitted 9/21/2015) says an ESCGP-2 was to be submitted in the fall of 2015. The well pad remains at its original size and the site currently does not conform to the permitted restoration plan. The original E&S permit has been expired since 10/16/2014.
The Department considers a well site to be restored under Section 3216(c) of the 2012 Oil and Gas Act when the oil or gas owners or operators meet the following: 1. All permanent post construction stormwater control features as identified in the Post Construction |
2774004 | Primary Facility | 2018-09-12 | Routine/Complete Inspection | No Violations Noted | Five wells staged for production phase. Five each water separators. The 2H well is using a sand separator. Dump lines wrapped in insulating blanket. No leaks detected from production equipment. Methanol tank in use on 2H well. No violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1820540 | 569412 | 08/11/2009 | 2009-08-11 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | CACP finalized 4/28/10, $4,300 penalty processed 4/29/10. See Insp ID 1829756 conducted 9/22/09, past violations corrected. MBC 9/23/09 |
1820540 | 569413 | 08/11/2009 | 2009-08-11 | 102.4INADPLN - E&S Plan not adequate | Administrative | CACP finalized 4/28/10, $4,300 penalty processed 4/29/10. See Insp ID 1829756 conducted 9/22/09, past violations corrected. MBC 9/23/09 |
1820540 | 569414 | 08/11/2009 | 2009-08-11 | 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used | Administrative | CACP finalized 4/28/10, $4,300 penalty processed 4/29/10. See Insp ID 1829756 conducted 9/22/09, past violations corrected. MBC 9/23/09 Condition 1 of ESCGP-1, unauthorized minor and major modifications of plan without approval. |
1820540 | 569415 | 08/11/2009 | 2009-08-11 | 401 CSL - Discharge of pollultional material to waters of Commonwealth. | Environmental Health & Safety | CACP finalized 4/28/10, $4,300 penalty processed 4/29/10. See Insp ID 1829756 conducted 9/22/09, past violations corrected. MBC 9/23/09 |
1825921 | 570868 | 09/04/2009 | 2009-09-04 | 105NOPERMIT - Encroachment without Permit or Waiver | Environmental Health & Safety | CACP finalized 4/28/10, $4,300 penalty processed 4/29/10. See Insp ID 1829756 conducted 9/22/09, past violations corrected. MBC 9/23/09 |
1861490 | 580835 | 01/27/2010 | 2010-01-27 | 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days | Administrative | 3/16/10 e-mail states past viols closed, Insp 1865832 & 1865862. |
1861490 | 580836 | 01/27/2010 | 2010-01-27 | 201A - Failure to have permit on site during drilling | Environmental Health & Safety | 3/16/10 e-mail states past viols closed, Insp 1865832 & 1865862. |
1861490 | 580837 | 01/27/2010 | 2010-01-27 | 78.85 - Inadequate, insufficient, and/or improperly installed cement | Environmental Health & Safety | 3/16/10 e-mail states past viols closed, Insp 1865832 & 1865862. |
1865829 | 582191 | 01/27/2010 | 2010-01-27 | 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days | Administrative | 3/16/10 e-mail states past viols closed, Insp 1865832 & 1865862. |
1865829 | 582192 | 01/27/2010 | 2010-01-27 | 78.85 - Inadequate, insufficient, and/or improperly installed cement | Environmental Health & Safety | 3/16/10 e-mail states past viols closed, Insp 1865832 & 1865862. |
1899634 | 591550 | 07/21/2010 | 2010-07-21 | 201TAG - Failure to install, in a permanent manner, the permit number on a completed well | Administrative | |
1899634 | 591551 | 07/21/2010 | 2010-07-21 | 78.56(3) - Impoundment not structurally sound, impermeable, 3rd party protected. | Administrative | |
1899634 | 591552 | 07/21/2010 | 2010-07-21 | 78.56(2) - Failure to maintain 2 ' of freeboard in an impoundment. | Administrative | |
1899634 | 591553 | 07/21/2010 | 2010-07-21 | 51017 - Administrative Code-General | Administrative | 35 PS 6018.301 |
1899634 | 591554 | 07/21/2010 | 2010-07-21 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | |
2051023 | 634463 | 03/15/2012 | 2012-03-15 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety | 78.57 cited in report, e-facts doesn't conform. Puddles that exceed limit of detection (>19.9mS/cm) white salty crusts on soil, damp soil with high conductiviyt around and potentially underneath NE tank battery (approximately 35,000 square feet). |
2051023 | 634464 | 03/15/2012 | 2012-03-15 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | |
2051023 | 634465 | 03/15/2012 | 2012-03-15 | 91.33A - Failure to notify DEP of pollution incident. No phone call made forthwith | Administrative | |
2051023 | 634466 | 03/15/2012 | 2012-03-15 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | 6018.610(2) cited. E-facts not compatible. Operation of an unpermitted transfer station. Produced fluids trucked from Houseknecht to Falk then piped to Kensinger. |
2051023 | 634467 | 03/15/2012 | 2012-03-15 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
569412 | 249476 | NOV - Notice of Violation | Comply/Closed | 2009-09-22 | |||
569412 | 256007 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2010-04-29 | 2010-04-28 | $4,300.00 | $4,300.00 |
569413 | 249476 | NOV - Notice of Violation | Comply/Closed | 2009-09-22 | |||
569413 | 256007 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2010-04-29 | 2010-04-28 | $4,300.00 | $4,300.00 |
569414 | 249476 | NOV - Notice of Violation | Comply/Closed | 2009-09-22 | |||
569414 | 256007 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2010-04-29 | 2010-04-28 | $4,300.00 | $4,300.00 |
569415 | 249476 | NOV - Notice of Violation | Comply/Closed | 2009-09-22 | |||
569415 | 256007 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2010-04-29 | 2010-04-28 | $4,300.00 | $4,300.00 |
570868 | 250147 | NOV - Notice of Violation | Comply/Closed | 2009-09-22 | |||
570868 | 256007 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2010-04-29 | 2010-04-28 | $4,300.00 | $4,300.00 |
580835 | 255598 | NOV - Notice of Violation | Comply/Closed | 2010-03-16 | |||
580836 | 255598 | NOV - Notice of Violation | Comply/Closed | 2010-03-16 | |||
580837 | 255598 | NOV - Notice of Violation | Comply/Closed | 2010-03-16 | |||
582191 | 255598 | NOV - Notice of Violation | Comply/Closed | 2010-03-16 | |||
582192 | 255598 | NOV - Notice of Violation | Comply/Closed | 2010-03-16 | |||
591550 | 261031 | NOV - Notice of Violation | Comply/Closed | 2011-08-31 | |||
591551 | 261031 | NOV - Notice of Violation | Comply/Closed | 2011-08-31 | |||
591552 | 261031 | NOV - Notice of Violation | Comply/Closed | 2011-08-31 | |||
591553 | 261031 | NOV - Notice of Violation | Comply/Closed | 2011-08-31 | |||
591554 | 261031 | NOV - Notice of Violation | Comply/Closed | 2011-08-31 | |||
634463 | 281608 | NOV - Notice of Violation | Comply/Closed | 2012-11-16 | |||
634463 | 290831 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2012-11-26 | 2012-11-26 | $26,842.00 | $26,842.00 |
634464 | 281608 | NOV - Notice of Violation | Comply/Closed | 2012-11-16 | |||
634464 | 290831 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2012-11-26 | 2012-11-26 | $26,842.00 | $26,842.00 |
634465 | 281608 | NOV - Notice of Violation | Comply/Closed | 2012-11-16 | |||
634465 | 290831 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2012-11-26 | 2012-11-26 | $26,842.00 | $26,842.00 |
634466 | 281608 | NOV - Notice of Violation | Comply/Closed | 2012-11-16 | |||
634466 | 290831 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2012-11-26 | 2012-11-26 | $26,842.00 | $26,842.00 |
634467 | 281608 | NOV - Notice of Violation | Comply/Closed | 2012-11-16 | |||
634467 | 290831 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2012-11-26 | 2012-11-26 | $26,842.00 | $26,842.00 |