Well ID: 37-081-20241 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.275677,"lon":-76.650126,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Penn Township | |
Operator Name: EXCO RESOURCES PA LLC | |
Well Pad ID: 149017 | |
Farm/Lease Name: PATTERSON UNIT 2H | |
License Status: | |
Spud Date: | |
Permit Date: 2009-12-22 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.275677 | |
Longitude: -76.650126 |
Date | Event |
---|---|
2009-12-22 | New Permit Application |
2010-02-01 | Performed Spud Operation |
2010-03-02 | Drilling Completion |
2010-07-25 | Perforation |
2010-09-23 | DEVIATED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2009 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | CHIEF OIL & GAS LLC | 395,890.00 | 88 | 0.00 | 0 | 0.00 | 0 |
2011 | EXCO RESOURCES PA LLC | 1,060,022.00 | 305 | 0.00 | 0 | 0.00 | 0 |
2012 | EXCO RESOURCES PA LLC | 984,830.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2013 | EXCO RESOURCES PA LLC | 699,762.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | EXCO RESOURCES PA LLC | 633,648.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | EXCO RESOURCES PA LLC | 440,242.00 | 320 | 0.00 | 0 | 0.00 | 0 |
2016 | EXCO RESOURCES PA LLC | 414,096.00 | 277 | 0.00 | 0 | 0.00 | 0 |
2017 | EXCO RESOURCES PA LLC | 452,158.00 | 337 | 0.00 | 0 | 0.00 | 0 |
2018 | EXCO RESOURCES PA LLC | 432,033.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | EXCO RESOURCES PA LLC | 390,673.00 | 363 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | CHIEF OIL & GAS LLC | Produced Fluid | 6,252.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW018 |
2010 | CHIEF OIL & GAS LLC | Drilling Fluid Waste | 162.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW018 |
2010 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 2,199.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2010 | CHIEF OIL & GAS LLC | Drilling Fluid Waste | 1,253.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2010 | CHIEF OIL & GAS LLC | Produced Fluid | 128.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2011 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 100.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2011 | CHIEF OIL & GAS LLC | Produced Fluid | 830.90 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2011 | EXCO RESOURCES PA LLC | Produced Fluid | 238.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2011 | EXCO RESOURCES PA LLC | Produced Fluid | 119.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PAS2D205BCLE |
2011 | EXCO RESOURCES PA LLC | Produced Fluid | 357.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2012 | EXCO RESOURCES PA LLC | Produced Fluid | 54.76 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | EXCO RESOURCES PA LLC | Produced Fluid | 385.70 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 54.76 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 204.76 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 23.80 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 57.14 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC009 |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 126.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 27.40 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 1,665.20 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 15.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC024 |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 1,503.70 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 154.70 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015 | EXCO RESOURCES PA LLC | Produced Fluid | 164.80 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2015 | EXCO RESOURCES PA LLC | Produced Fluid | 2,193.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EXCO RESOURCES PA LLC | Produced Fluid | 220.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2017 | EXCO RESOURCES PA LLC | Produced Fluid | 819.50 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2018 | EXCO RESOURCES PA LLC | Produced Fluid | 135.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2018 | EXCO RESOURCES PA LLC | Produced Fluid | 122.90 Bbl | REUSE (AT WELL PAD) | |
2018 | EXCO RESOURCES PA LLC | Produced Fluid | 121.40 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2019 | EXCO RESOURCES PA LLC | Produced Fluid | 227.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2019 | EXCO RESOURCES PA LLC | Produced Fluid | 80.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1862155 | Primary Facility | 2010-02-09 | Routine/Complete Inspection | No Violations Noted | |
1865827 | Primary Facility | 2010-02-16 | Drilling/Alteration | Violation(s) Noted | |
1929614 | Primary Facility | 2010-11-15 | Follow-up Inspection | No Violations Noted | |
1941449 | Primary Facility | 2011-01-05 | Routine/Complete Inspection | No Violations Noted | |
1961804 | Primary Facility | 2011-03-30 | Routine/Partial Inspection | No Violations Noted | |
1965853 | Primary Facility | 2011-01-14 | Routine/Complete Inspection | No Violations Noted | |
1966510 | Primary Facility | 2011-04-18 | Routine/Complete Inspection | No Violations Noted | |
2060351 | Primary Facility | 2012-04-17 | Routine/Complete Inspection | No Violations Noted | |
2062941 | Primary Facility | 2012-04-25 | Routine/Complete Inspection | No Violations Noted | |
2092499 | Primary Facility | 2012-08-15 | Routine/Complete Inspection | No Violations Noted | |
2116530 | Primary Facility | 2012-11-15 | Incident- Response to Accident or Event | No Violations Noted | |
2120889 | Primary Facility | 2012-12-04 | Compliance Evaluation | No Violations Noted | |
2462734 | Primary Facility | 2016-03-09 | Routine/Complete Inspection | Violation(s) Noted | Methane monitoring yielded 4% on 13-3/8" x 9-5/8" annulus |
2543924 | Primary Facility | 2016-12-08 | Routine/Complete Inspection | No Violations Noted | Routine Inspection; 12/8/2016. I entered the location at 09:57 and began the inspection. At the time of the inspection, the Patterson Unit 1H (081-20240), 2H (081-20241), 4H (081-20243), and 5H (081-20244) wells were in production. The well pad area was well vegetated and can be considered permanently stabilized. The well site has not been restored and the Well Site Compliance Information Request reply (submitted 9/21/2015) says the well site has been restored and the Notice of Termination was to be submitted in September of 2015. The well pad remains at its original size and the site currently does not conform to the permitted restoration plan. The original ESCGP has been expired since 11/23/2014.
The Department considers a well site to be restored under Section 3216(c) of the 2012 Oil and Gas Act when the oil or gas owners or operators meet the following: 1. All permanent post construction stormwater control features as identified in the Post Construction Stormwater Management/Site Restoration Pla |
2577272 | Primary Facility | 2017-03-28 | Routine/Complete Inspection | Outstanding Violations - Viols Req'd | Arrived @ 10:00. Weather: cloudy, warm, light rain. There are 4 wells capable of production on location. At the time of my inspection the 1H and 2H were in production, 4H and 5H were locked and shut-in. There were 3 annular vent pipes at each well. All well cellars were filled with gravel. The annuli for the 2H were configured differently, but for the other wells, the 20” x 13-3/8” and 13-3/8” x 9-5/8” were open and the 9-5/8” x 5-1/2” was plumbed to a dump line. The annuli were monitored with an Altair 5X gas meter calibrated on 03/28/17. No combustible gas was detected at the annuli of the: 1H, 4H, and 5H. The annuli for the 2H were linked together and it was not possible at the time of my inspection to test for gas (see photo).
Patterson 1H: top gauge: 300 psi (0-5000 analog) Patterson 2H; top gauge: 300 psi (0-3000 analog) No new violations were observed during this inspection. The result for this inspection is OUTST, for outstanding violation because a violation for defective cement was cited on 3/9/1 |
2584429 | Primary Facility | 2017-04-18 | Follow-up Inspection | Outstanding Violations - Viols Req'd | : Arrived @ 8:30. Weather sunny. Met with Bird Smith and Bobby Hamel (EXCO) to better understand the Patterson 2H annular venting configuration observed in my previous inspection (03/28/17, IR#: 2577272). For the 2H annuli, ¼” stainless tubing connected the 20” x 13-3/8” and 13-3/8” x 9-5/8” to the 9-5/8” x 5-1/2” annular vent. Needle valves on the ¼” could isolate any annulus. The well tender, Bobby Hamel, explained that he added the tubing to allow more control for monitoring or sample collection following my inspection of 3/9/16 which cited a violation of defective cement because methane was detected on the 13-3/8” x 9-5/8” annulus (IR# 2462734). Field monitoring of the annular vents (Altair 5X gas meter calibrated on 4/11/17) did not detect combustible gas on the 20” x 13-3/8” and 13-3/8” x 9-5/8”. For the 9-5/8” x 5-1/2” annulus, 20% combustible gas was detected. The result of this inspection is OUTST, for outstanding violation, because a violation for defective cement was cited on 3/9/16 (IR# 2462734) |
2679414 | Primary Facility | 2018-01-03 | Routine/Complete Inspection | No Violations Noted | Arrived at 15:00. 4 wells on location, 1H and 2H producing, 4H and 5H locken and shut-in. All wells on active status. Followed up with Bird Smith who said that wells produce large amounts of water, so production is limited. |
2694385 | Primary Facility | 2018-02-14 | Routine/Complete Inspection | No Violations Noted | Weather was 30° and cloudy at time of inspection. Met with lease operator Bobby Hamel on location at time of inspection. Well had an analog pressure gauge attached above the swab valve. Pressure was approximately 270 psi at time of inspection. There were three annulus vents plumbed to surface. The 5 1/2 x 9 5/8 annulus vent was plumbed across location to the produced water tanks. The 9 5/8 x 13 3/8 and 13 3/8 x 20 annulus vents were open and 0% combustible gas was detected at time of inspection. No violations were noted at time of inspection. |
2832709 | Primary Facility | 2019-01-28 | Routine/Complete Inspection | No Violations Noted | On January 28, 2019, Department representative Brad Kline conducted a routine site inspection at EXCO Resources, LLC. Patterson Unit 1 pad. Site inspection log was onsite for review. No E&S issues were observed during the time of inspection. The site is stable and well vegetated meeting the 70% uniform, perennial, vegetative cover.
There are a total of 4 producing wells located on this well pad. All wells are tagged with API/well permit numbers. Well cellars are filled in with gravel. There are 4 GPU’s and 2 steel vertical production fluids tanks onsite. Production fluid tanks and GPUs were stationed in separate secondary containment. No violations noted. The Department recommends submitting a Notice of Termination and a Post-Drilling Well Site Restoration Report when the criteria are met and weather conditions permit. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1865827 | 582190 | 02/16/2010 | 2010-02-16 | 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling | Administrative | |
2462734 | 753751 | 2016-03-09 | 78.86 | Environmental Health & Safety | 13-3/8-9-5/8" annular vent monitoring yields 4% methane | |
2577272 | 782214 | 2016-03-09 | 78.86 | Environmental Health & Safety | 5% methane on the 13-3/8" x 9-5/8" annulus. | |
2584429 | 783541 | 2016-03-09 | 78.86 | Environmental Health & Safety |