If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-20712 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.364206,"lon":-77.024878,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Gamble Township | |
Operator Name: SENECA RESOURCES CO LLC | |
Well Pad ID: 150843 | |
Farm/Lease Name: SPRAGLEY OAK 1H | |
License Status: | |
Spud Date: | |
Permit Date: 2011-10-05 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 41.364206 | |
Longitude: -77.024878 |
Date | Event |
---|---|
2011-02-20 | Drilling Completion |
2011-10-05 | New Permit Application |
2011-12-23 | Performed Spud Operation |
2012-04-11 | Perforation |
2012-07-20 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-04-16 | 2012-04-16 | 8,479 | 4,905,978 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Proppant 40/70 Ottawa | Universal Well Services | Proppant | Quartz | 14808-60-7 | 100.00 | 4.14 | |
Nalco Scale Inhibitor | Universal Well Services | Scale Inhibitor | Ethylene glycol | 107-21-1 | 30.00 | 0.00469437 | ||
Iron Stabilizer II | Universal Well Services | Corrosion Inhibitor | Ethylene glycol | 107-21-1 | 30.00 | 0.00098972 | ||
CFT-2100 | Core Laboratories | Chemical Tracer | Water | 7732-18-5 | 90.00 | 0.00005097 | ||
Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00000566 | ||||||
CFT-2000 | Core Laboratories | Chemical Tracer | Water | 7732-18-5 | 90.00 | 0.00004884 | ||
Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00000543 | ||||||
CFT-2200 | Core Laboratories | Chemical Tracer | Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00000554 | |||
Water | 7732-18-5 | 90.00 | 0.00004990 | |||||
CFT-1900 | Core Laboratories | Chemical Tracer | Water | 7732-18-5 | 90.00 | 0.00004990 | ||
Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00000554 | ||||||
CFT-2400 | Core Laboratories | Chemical Tracer | Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00000661 | |||
Water | 7732-18-5 | 90.00 | 0.00005946 | |||||
Proppant 30/50 Ottawa | Universal Well Services | Proppant | Quartz | 14808-60-7 | 100.00 | 3.78 | ||
BioRid 71 | Tetra | Biocide | Sodium hydroxide | 1310-73-2 | 5.00 | 0.00107551 | ||
Alkaline Bromide Salts | 7.10 | 0.00152723 | ||||||
15 HydroChloric Acid | Universal Well Services | Acid | Hydrochloric acid | 7647-01-0 | 15.00 | 0.01 | ||
Unislik ST 50 | Universal Well Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 | ||
CFT-2500 | Core Laboratories | Chemical Tracer | Water | 7732-18-5 | 90.00 | 0.00010299 | ||
Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00001144 | ||||||
CFT-1200 | Core Laboratories | Chemical Tracer | Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00000519 | |||
Water | 7732-18-5 | 90.00 | 0.00004672 | |||||
CFT-1300 | Core Laboratories | Chemical Tracer | Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00000519 | |||
Water | 7732-18-5 | 90.00 | 0.00004672 | |||||
CFT-1500 | Core Laboratories | Chemical Tracer | Water | 7732-18-5 | 90.00 | 0.00004778 | ||
Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00000531 | ||||||
CFT-1000 | Core Laboratories | Chemical Tracer | Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00000519 | |||
Water | 7732-18-5 | 90.00 | 0.00004672 | |||||
Proppant 80/100 Oklahoma | Universal Well Services | Proppant | Quartz | 14808-60-7 | 100.00 | 0.12 | ||
CFT-1600 | Core Laboratories | Chemical Tracer | Aqueous Solution | |||||
Water | 7732-18-5 | 90.00 | 0.00004566 | |||||
Proprietary Ingredient supplied as 10 w/v | 10.00 | 0.00000507 | ||||||
Unigel 5F | Universal Well Services | Guar Gel Dry Add | Guar Gum | 100.00 | 0.00056179 | |||
7.5 HydroChloric Acid | Universal Well Services | Acid | Hydrochloric acid | 7647-01-0 | 7.50 | 0.06 | ||
GB L | Universal Well Services | Breaker | Ethylene glycol | 107-21-1 | 60.00 | 0.00000847 | ||
CFT-1100 | Core Laboratories | Chemical Tracer | Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00000543 | |||
Water | 7732-18-5 | 90.00 | 0.00004884 | |||||
CFT-1700 | Core Laboratories | Chemical Tracer | Water | 7732-18-5 | 90.00 | 0.00005203 | ||
Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00000578 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | SENECA RESOURCES CO LLC | 890,453.00 | 167 | 0.00 | 0 | 0.00 | 0 |
2013 | SENECA RESOURCES CO LLC | 1,057,150.00 | 335 | 0.00 | 0 | 0.00 | 0 |
2014 | SENECA RESOURCES CO LLC | 790,803.80 | 360 | 0.00 | 0 | 0.00 | 0 |
2015 | SENECA RESOURCES CO LLC | 326,574.89 | 137 | 0.00 | 0 | 0.00 | 0 |
2016 | SENECA RESOURCES CO LLC | 639,467.78 | 297 | 0.00 | 0 | 0.00 | 0 |
2017 | SENECA RESOURCES CO LLC | 506,412.73 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | SENECA RESOURCES CO LLC | 410,821.37 | 353 | 0.00 | 0 | 0.00 | 0 |
2019 | SENECA RESOURCES CO LLC | 427,774.60 | 337 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | SENECA RESOURCES CO LLC | Drill Cuttings | 30.45 Tons | LANDFILL | 301358 |
2012 | SENECA RESOURCES CO LLC | Produced Fluid | 1,050.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2012 | SENECA RESOURCES CO LLC | Produced Fluid | 1,345.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | SENECA RESOURCES CO LLC | Fracing Fluid Waste | 5,084.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | SENECA RESOURCES CO LLC | Produced Fluid | 4,230.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC006 |
2012 | SENECA RESOURCES CO LLC | Drill Cuttings | 1,833.43 Tons | LANDFILL | 301358 |
2012 | SENECA RESOURCES CO LLC | Produced Fluid | 580.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2013 | SENECA RESOURCES CO LLC | Produced Fluid | 2,300.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | SENECA RESOURCES CO LLC | Produced Fluid | 209.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 73.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 330.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 30.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2017 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 60.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2017 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 130.00 Bbl | REUSE (AT WELL PAD) | |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 283.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 345.00 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 185.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 150.00 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 2,560.00 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 140.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 25.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 80.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2019 | SENECA RESOURCES CO LLC | Synthetic Liner Materials | 0.69 Tons | LANDFILL | 301358 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 65.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 30.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2019 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 32.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2019 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 220.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 130.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2032880 | Primary Facility | 2012-01-10 | Drilling/Alteration | No Violations Noted | |
2042355 | Primary Facility | 2012-02-13 | Drilling/Alteration | No Violations Noted | |
2062806 | Primary Facility | 2012-04-25 | Routine/Complete Inspection | No Violations Noted | |
2068999 | Primary Facility | 2012-05-17 | Drilling/Alteration | No Violations Noted | |
2083397 | Primary Facility | 2012-07-16 | Routine/Complete Inspection | No Violations Noted | |
2095705 | Primary Facility | 2012-08-27 | Routine/Complete Inspection | Violation(s) Noted | |
2119073 | Primary Facility | 2012-11-28 | Routine/Complete Inspection | No Violations Noted | |
2248886 | Primary Facility | 2014-02-26 | Incident- Response to Accident or Event | Viol(s) Noted & Immediately Corrected | Brine spill to the pad, excavated and staged in roll-off box. VIOIC |
2249154 | Primary Facility | 2014-02-28 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | |
2438603 | Primary Facility | 2016-01-04 | Complaint Inspection | Outstanding Violations - No Viols Req'd | Weather: cold, sunny, surface water was frozen, snow was on the ground. Arrived @ 12:15. There was no activity on the site. There was one well in production on the pad. The well was tagged and there was a grate over the cellar which had frozen water, no BAW. There are steel plates covering the outer annuli with ½” stainless steel vent lines at the surface. The lines are labeled.
Methane gas was monitored with an Altair 5X gas meter calibrated on 1/4/2016. 20” x 13-3/8” – 0% methane 13-3/8” x 9-5/8” – 0% methane 9-5/8” x 5-1/2” – 100% methane. The 9-5/8” x 5-1/2” annulus is plumbed to a poly tank. Methane was also detected at the tank vent. A previous inspection (IR# 2095705), cited a violation for defective cement on the 9-5/8” x 5-1/2” annulus because there was evidence in the well record to suggest that the production casing was cemented to surface. No additional violations were noted during this inspection. Consequently, the result of this inspection is: OUTNO. |
2483379 | Primary Facility | 2016-05-03 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | Weather: cool. Arrived @ 15:00. There was no activity on the site. There was one well in production on the pad. It was surrounded by concrete barriers. The well was tagged and there was a grate over the cellar. There are steel plates covering the outer annuli with 3/8” stainless steel vent lines at the surface. The lines are labeled.
Methane gas was monitored with an Altair 5X gas meter calibrated on 4/27/16. 20” x 13-3/8” – 0% methane 13-3/8” x 9-5/8” – 0% methane 9-5/8” x 5-1/2” – 100% methane. The 9-5/8” x 5-1/2” annulus is plumbed to a poly tank. 2.5% methane was also detected at the tank vent. A previous inspection (IR# 2095705), cited a violation for defective cement on the 9-5/8” x 5-1/2” annulus because there was evidence in the well record to suggest that the production casing was cemented to surface. No additional violations were noted during this inspection. Consequently, the result of this inspection is: OUTNO |
2820081 | Primary Facility | 2018-12-28 | Routine/Complete Inspection | No Violations Noted | One well staged for production phase. One GPU within containment. No leaks detected from production equipment. No violations noted. |
2847654 | Primary Facility | 2019-03-04 | Routine/Complete Inspection | No Violations Noted | Note: This site was inspected on 12/28/2018.
One well staged for production phase. One GPU within Containment. No leaks detected from production equipment. No violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2095705 | 647886 | 08/27/2012 | 2012-08-27 | 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days | Administrative | Gas found in the 9 5/8 x 5 1/2 annulus. |
2248886 | 689627 | 02/26/2014 | 2014-02-26 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | Brine spill to the pad, excavated vioic |
2248886 | 689628 | 02/26/2014 | 2014-02-26 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety | Brine spill to the pad, excavated vioic |
2248886 | 689629 | 02/26/2014 | 2014-02-26 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | Brine spill to the pad, excavated vioic |
For data sources see[8]