X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-081-20797

Well Details

Well ID: 37-081-20797
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Cogan House Township
Operator Name: ARD OPR LLC
Well Pad ID: 148153
Farm/Lease Name: CYNTHIA M KNISPEL A 3H
License Status:
Spud Date:
Permit Date: 2011-12-28
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.405664
Longitude: -77.220772

For data sources see[1][2][3]

Well History

Date Event
2011-12-28 New Permit Application
2012-01-22 Performed Spud Operation
2012-08-31 Drilling Completion
2012-12-09 Perforation
2014-03-04 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-12-23 2012-12-23 7,427 3,261,443

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Acid, Hydrochloric (3.5) Trican Well Service General Acidizing Hydrochloric acid 7647-01-0 15.00 0.00
Sand (Proppant) Trican Well Service Proppant Quartz 14808-60-7 70.00 11.10
Methenamine 100-97-0 1.00 0.15
FR-8 Trican Well Service Friction Reducer Ammonium chloride 12125-02-9 1.50 0.00088000
Distillates, petroleum, hydrotreated light 64742-47-8 28.00 0.01
WXB-10 Trican Well Service Fracturing Crosslinker Ulexite 1319-33-1 60.00 0.00
Distillates, petroleum, hydrotreated light 64742-47-8 60.00 0.00
WG-111L Trican Well Service Viscosifier/Gelant Polysaccharide blend 60.00 0.00
Distillates, petroleum, hydrotreated light 64742-47-8 60.00 0.00
TXP-8 Trican Well Service Friction Reducer Cationic water-soluble polymer emulsion 100.00 0.00
WBO-2 Trican Well Service Gel Breaker Sodium persulfate 7775-27-1 100.00 0.00
GBO-1 Trican Well Service Gel Breaker Sodium perborate tetrahydrate 10486-00-7 100.00 0.00
TXP-11 Trican Well Service Clay Stabilizer Chloride 16887-00-6 30.00 0.00
Water 7732-18-5 60.00 0.00
Poly electrolyte 40.00 0.00
Inorganic chemical 20.00 0.00
Acid, Hydrochloric (3.5) General Acidizing Water 7732-18-5 85.00 0.00
Biobrom C-100G Trican Well Service Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 98.00 0.00
WG-111D Trican Well Service Water Gellant Guar gum 9000-30-0 100.00 0.00
Water Anadarko Carrier/Base Fluid Water 7732-18-5 100.00 83.44
CS-1 Trican Well Service Clay Stabilizer Inorganic salts 30.00 0.00
1,2-Propylene glycol 57-55-6 20.00 0.00
Surfactant 5.00 0.00
Blend 25.00 0.00
TXP-10 Trican Well Service Scale Inhibitor Acrylate phosphonate copolymer 40.00 0.00299000
1,2-Propylene glycol 57-55-6 10.00 0.00075000
Water 7732-18-5 70.00 0.00524000
Neutralized organic acid 20.00 0.00150000
WBE-6 Trican Well Service Gel Breaker No hazardous ingredients 100.00 0.00
BXL-A Trican Well Service Gel Breaker Proprietary 70.00 0.00
Acid, Hydrochloric (7.5) General Acidizing
FR-14 Trican Well Service Friction Reducer Acetic acid 64-19-7 5.00 0.00
Inorganic salt 30.00 0.00
FEAC-20 Trican Well Service Iron Control Acetic acid 64-19-7 50.00 0.00266000
Citric acid 77-92-9 30.00 0.00159000
BioClear 5000 Trican Well Service Biocide Polyethylene glycol 25322-68-3 70.00 0.01
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 10.00 0.00237000
DF-1 Trican Well Service Defoaming Agent Non-hazardous materials only in the product 100.00 0.00
Sand (Proppant) Proppant
Acid, Hydrochloric (7.5) Trican Well Service General Acidizing Water 7732-18-5 92.50 0.54
Hydrochloric acid 7647-01-0 7.50 0.04
AI-7NR Trican Well Service Corrosion Inhibitor Propargyl alcohol 107-19-7 1.00 0.00002000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2012 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2013 ANADARKO E&P ONSHORE LLC 415,547.00 209 0.00 0 0.00 0
2014 ANADARKO E&P ONSHORE LLC 317,842.00 353 0.00 0 0.00 0
2015 ANADARKO E&P ONSHORE LLC 137,263.00 216 0.00 0 0.00 0
2016 ANADARKO E&P ONSHORE LLC 215,607.00 355 0.00 0 0.00 0
2017 ARD OPR LLC 134,839.41 341 0.00 0 0.00 0
2018 ARD OPR LLC 94,876.48 307 0.00 0 0.00 0
2019 ARD OPR LLC 111,171.85 356 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 ANADARKO E&P ONSHORE LLC Drill Cuttings 32.59 Tons LANDFILL 06-08438
2012 ANADARKO E&P ONSHORE LLC Drill Cuttings 979.40 Tons LANDFILL 301626
2013 ANADARKO E&P ONSHORE LLC Produced Fluid 23,835.61 Bbl REUSE OTHER THAN ROAD SPREADING
2014 ANADARKO E&P ONSHORE LLC Produced Fluid 7,694.42 Bbl REUSE OTHER THAN ROAD SPREADING
2015 ANADARKO E&P ONSHORE LLC Produced Fluid 442.90 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 ANADARKO E&P ONSHORE LLC Produced Fluid 219.66 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2015 ANADARKO E&P ONSHORE LLC Produced Fluid 2,374.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 179.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 222.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 213.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 1,533.47 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 9.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 211.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 2,292.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 480.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 1,994.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 9.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 497.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017 ARD OPR LLC Produced Fluid 93.04 Bbl REUSE (AT WELL PAD)
2018 ARD OPR LLC Produced Fluid 48.95 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 ARD OPR LLC Produced Fluid 564.43 Bbl REUSE (AT WELL PAD)
2018 ARD OPR LLC Produced Fluid 11.41 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 ARD OPR LLC Produced Fluid 37.43 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 ARD OPR LLC Produced Fluid 1,230.54 Bbl REUSE (AT WELL PAD)
2019 ARD OPR LLC Servicing Fluid 38.22 Bbl REUSE (AT WELL PAD)
2019 ARD OPR LLC Produced Fluid 95.41 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2063641 Primary Facility 2012-04-30 Routine/Complete Inspection No Violations Noted
2084193 Primary Facility 2012-07-18 Drilling/Alteration No Violations Noted
2124772 Primary Facility 2012-12-18 Routine/Complete Inspection No Violations Noted
2124917 Primary Facility 2012-12-19 Drilling/Alteration No Violations Noted
2221948 Primary Facility 2013-11-05 Routine/Complete Inspection No Violations Noted
2521439 Primary Facility 2016-09-15 Routine/Complete Inspection No Violations Noted Routine Inspection; 9/15/2016.

I entered the location at 13:16 and began the inspection. At the time of the inspection, five producing wells (081-20796, 081-20559, 081-20797, 081-20798, and 081-20561) and one plugged well were located onsite. The well site was in good condition and no E&S issues were observed. The site has no active well permits that have not been drilled.

ESX10-081-0086 expired on 10/26/2015 without being terminated and the site has not been restored. The wells onsite were drilled from 2011 to 2012 and the well site has not been restored. Anadarko’s most recent restoration timeline submission indicates PCSM will be permitted in 2016 and installed in 2017.

The Department considers a well site to be restored under Section 3216(c) of the 2012 Oil and Gas Act when the oil or gas owners or operators meet the following:

1. All permanent post construction stormwater control features as   the Post Construction Stormwater Management/Site Restoration Plan are in place.

2. Remaining impervious

2582224 Primary Facility 2017-03-23 Routine/Complete Inspection No Violations Noted Routine inspection of unconventional well in production. No violations noted at time of inspection.
2742883 Primary Facility 2018-06-13 Routine/Complete Inspection No Violations Noted Spill Response Inspection; 6/13/2018.

Rick Hall (ARD) reported the release of approximately 630 gallons of Salt Treatment Fluid (STF) to the well pad surface at the back-pressure valve on the injection/re-circulation line at about 10:20. The release was discovered about 30 minutes prior to the spill reporting. After viewing volume trends in the STF tank, the operator estimates the leak began approximately a week ago. The STF is injected into the wells onsite and is comprised of fresh water with a biocide, scale/corrosion inhibitor, de-foamer, and methanol. The concentration of methanol is unknown but believed to be much less than 30%. I called Mr. Hall and we planned to meet onsite.

At 13:45 Thomas McNerney (DEP ECB Program) and I met with Rick Hall and Mark Barbier (both ARD). Soon afterward the well operator, Mark Aungst (ARD), arrived onsite. Two representatives from Leidos arrived later to collect samples. Mr. Aungst explained the STF system and the location of the valve which leaked. Leidos representat

2778236 Primary Facility 2018-09-21 Routine/Complete Inspection No Violations Noted Five wells staged for production phase. One well plugged (081-20510). Five each water separators. Two sand separators. No leaks detected from production equipment. Methanol tanks located near well heads. No violations noted.

For data sources see[8]