If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-20916 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.474528,"lon":-77.157422,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Cogan House Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 148351 | |
Farm/Lease Name: FLICKS RUN 4H | |
License Status: | |
Spud Date: | |
Permit Date: 2012-03-06 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.474528 | |
Longitude: -77.157422 |
Date | Event |
---|---|
2012-03-06 | New Permit Application |
2012-06-01 | Performed Spud Operation |
2012-07-18 | New Permit Application |
2012-10-19 | Drilling Completion |
2013-01-05 | Perforation |
2014-03-04 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-01-05 | 2013-01-05 | 8,138 | 5,325,012 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | SI-115 | Clearwater International | Scale Inhibitor | Sodium chloride | 7647-14-5 | 5.00 | 0.00054000 | |
Phosphonic acid, [[(phosphonomethyl)imino]bis[2,1-ethanediylnitrilobis(methylene)]]tetrakis-, sodium salt |
22042-96-2 | 20.00 | 0.00217000 | |||||
15 HCl | Acid | Hydrochloric acid | 7647-01-0 | 15.00 | 0.12 | |||
Water | Southwestern Energy | Water/Produced Water | H2O + Disolved Salts | 100.00 | 90.77 | |||
Sand | Various | Sand | Quartz | 14808-60-7 | 100.00 | 8.26 | ||
SI-112 | Clearwater International | Scale Inhibitor | Ethylene glycol | 107-21-1 | 40.00 | 0.00032000 | ||
AI-250 | Clearwater International | Acid Inhibitor | Propargyl alcohol | 107-19-7 | 40.00 | 0.00084000 | ||
Isopropanol | 67-63-0 | 40.00 | 0.00084000 | |||||
2-Butoxyethanol | 111-76-2 | 40.00 | 0.00084000 | |||||
ASP 900 | Nalco | Friction Reducer | Non Hazardous | 100.00 | 0.00061000 | |||
FRA-405 | Clearwater International | Friction Reducer | Sodium chloride | 7647-14-5 | 7.50 | 0.00630000 | ||
Ammonium chloride | 12125-02-9 | 5.00 | 0.00420000 | |||||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 27.50 | 0.02 | |||||
Ethoxylated C12-16 alcohols | 68551-12-2 | 5.00 | 0.00420000 | |||||
K Bac 1020 | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.00264000 | |||
Polyethylene glycol | 25322-68-3 | 60.00 | 0.00791000 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | SOUTHWESTERN ENERGY PROD CO | 1,352,391.00 | 326 | 0.00 | 0 | 0.00 | 0 |
2014 | SOUTHWESTERN ENERGY PROD CO | 931,347.00 | 338 | 0.00 | 0 | 0.00 | 0 |
2015 | SWN PROD CO LLC | 700,489.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | SWN PROD CO LLC | 548,908.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | SWN PROD CO LLC | 441,856.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | SWN PROD CO LLC | 403,217.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | SWN PROD CO LLC | 361,242.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | SOUTHWESTERN ENERGY PROD CO | Drilling Fluid Waste | 324.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2012 | SOUTHWESTERN ENERGY PROD CO | Drill Cuttings | 2,417.91 Tons | LANDFILL | 101247 |
2013 | SOUTHWESTERN ENERGY PROD CO | Produced Fluid | 9,457.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | SOUTHWESTERN ENERGY PROD CO | Fracing Fluid Waste | 352.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | SOUTHWESTERN ENERGY PROD CO | Drilling Fluid Waste | 102.26 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2013 | SOUTHWESTERN ENERGY PROD CO | Fracing Fluid Waste | 313.93 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2013 | SOUTHWESTERN ENERGY PROD CO | Produced Fluid | 413.26 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2013 | SOUTHWESTERN ENERGY PROD CO | Fracturing Fluid Waste | 14.02 Tons | LANDFILL | 101247 |
2014 | SOUTHWESTERN ENERGY PROD CO | Produced Fluid | 6,374.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | SWN PROD CO LLC | Produced Fluid | 4,465.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWN PROD CO LLC | Produced Fluid | 336.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWN PROD CO LLC | Produced Fluid | 200.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2016 | SWN PROD CO LLC | Produced Fluid | 131.67 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | SWN PROD CO LLC | Produced Fluid | 2,132.32 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2017 | SWN PROD CO LLC | Produced Fluid | 168.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 23.33 Bbl | REUSE (AT WELL PAD) | |
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 18.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 23.33 Bbl | SURFACE IMPOUNDMENT | 826342 |
2017 | SWN PROD CO LLC | Produced Fluid | 305.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2017 | SWN PROD CO LLC | Produced Fluid | 503.34 Bbl | REUSE (AT WELL PAD) | |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 52.06 Bbl | REUSE (AT WELL PAD) | |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 105.13 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018 | SWN PROD CO LLC | Produced Fluid | 18.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018 | SWN PROD CO LLC | Produced Fluid | 398.66 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018 | SWN PROD CO LLC | Produced Fluid | 549.99 Bbl | REUSE (AT WELL PAD) | |
2018 | SWN PROD CO LLC | Produced Fluid | 933.83 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 117.39 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 165.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC035 |
2019 | SWN PROD CO LLC | Produced Fluid | 484.17 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Servicing Fluid | 0.04 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301333 |
2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 4.00 Bbl | REUSE (AT WELL PAD) | |
2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 3.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC035 |
2019 | SWN PROD CO LLC | Produced Fluid | 21.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 17.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 557.50 Bbl | REUSE (AT WELL PAD) | |
2019 | SWN PROD CO LLC | Produced Fluid | 241.66 Bbl | SURFACE IMPOUNDMENT | 826342 |
2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 8.80 Bbl | SURFACE IMPOUNDMENT | 826342 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2061816 | Primary Facility | 2012-04-18 | Routine/Complete Inspection | No Violations Noted | Pad construction and access road look good, no E&S issues, soil stockpile stabilized. No Vio. |
2075660 | Primary Facility | 2012-06-13 | Drilling/Alteration | No Violations Noted | |
2081791 | Primary Facility | 2012-07-09 | Routine/Complete Inspection | No Violations Noted | |
2089689 | Primary Facility | 2012-08-06 | Routine/Partial Inspection | No Violations Noted | |
2101636 | Primary Facility | 2012-09-19 | Drilling/Alteration | No Violations Noted | |
2111008 | Primary Facility | 2012-10-25 | Drilling/Alteration | No Violations Noted | |
2128536 | Primary Facility | 2012-12-24 | Routine/Complete Inspection | No Violations Noted | spills reported were contained to the well pad liner |
2129222 | Primary Facility | 2013-01-07 | Routine/Complete Inspection | No Violations Noted | Reported 10 barrel brine spill on containment |
2152248 | Primary Facility | 2013-03-29 | Drilling/Alteration | No Violations Noted | |
2178688 | Primary Facility | 2013-06-19 | Routine/Complete Inspection | No Violations Noted | responded to spill of diesel based mud to containment. No indication of holes or leaving containment |
2243202 | Primary Facility | 2014-01-30 | Routine/Partial Inspection | No Violations Noted | installing production facilities and removing containment liner. No Vio. |
2247703 | Primary Facility | 2014-02-20 | Incident- Response to Accident or Event | No Violations Noted | brine spill to containment clean-up initiated promptly. no vio |
2264666 | Primary Facility | 2014-03-26 | Routine/Complete Inspection | No Violations Noted | |
2425861 | Primary Facility | 2015-11-03 | Routine/Complete Inspection | No Violations Noted | Routine Inspection. No violations noted. |
2482631 | Primary Facility | 2016-05-11 | Routine/Complete Inspection | No Violations Noted | I entered the location at 09:26 and began the inspection. At the time of the inspection, the Flicks Run 1H (081-20913), 2H (081-20914), 3H (081-20915), 4H (081-20916), 5H (081-20917), and 6H (081-20918) were in production. The well pad area and access road are all stabilized and no erosion was noted. The well site has not been restored and the sedimentation basins have not been converted to infiltration basins based on the PCSM (Post Construction Stormwater Management) plan modification approved on November 21, 2011. Rock Infiltration sumps along the access road have been installed as designed in the PCSM plans. The revised restoration assessment acknowledges the well site has not been restored and drilling ended on 6/28/2013. The well pad remains at its original size and no well permits have been issued since 2012.
The Department considers a well site to be restored under Section 3216(c) of the 2012 Oil and Gas Act when the oil or gas owners or operators meet the following: 1. All permanent post co |
2664220 | Primary Facility | 2017-11-27 | Routine/Complete Inspection | No Violations Noted | Weather is 42 deg. F, sunny and windy.
No annulus vent observed at the time of inspection. 0% combustible gas detected at the time of inspection. A smell associated with natural gas wells was detected, but could not determine the source. Well head digital gauge shows 325 PSI production tubing, and 441 PSI on production casing. |
2681145 | Primary Facility | 2018-01-03 | Routine/Complete Inspection | No Violations Noted | The access road (including stream crossings and drainage features) from the Flicks Run East to the well pad itself was in good condition and well maintained. A few inches of snow was covering the entire site. On the well pad, six wells were in production. Sand separators remain installed at the production units and both (for each well) are in containment. No staining was visible around any of the production equipment.The ESCGP permit has expired and Post Construction Stormwater Management (PCSM) has not yet been permitted or implemented. I recommend re-permitting the site and following the COA which indicates this site will be restored in 2020. No violations noted. |
2802092 | Primary Facility | 2018-11-13 | Routine/Complete Inspection | No Violations Noted | Six wells stage for production. Six each sand and water separators within containment. No leaks detected from production equipment. No violations noted. |
For data sources see[8]