If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
| Well ID: 37-081-21088 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.400886,"lon":-77.167844,"icon":""}]} |
| Country: United States | |
| State: Pennsylvania | |
| County: Lycoming | |
| Municipality: Cogan House Township | |
| Operator Name: ARD OPR LLC | |
| Well Pad ID: 146226 | |
| Farm/Lease Name: TERRY D LITZELMAN A 201H | |
| License Status: | |
| Spud Date: | |
| Permit Date: 2012-12-04 | |
| Well Type: GAS | |
| Unconventional Well: Y | |
| Configuration: Horizontal Well | |
| Conservation: No | |
| Latitude: 41.400886 | |
| Longitude: -77.167844 |
| Date | Event |
|---|---|
| 2012-12-04 | New Permit Application |
| 2012-12-17 | Performed Spud Operation |
| 2013-04-16 | Drilling Completion |
| 2013-07-22 | Perforation |
| 2014-03-05 | DEVIATED |
For data sources see[4]
| Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
|---|---|---|---|---|---|
| 1 | 2013-07-23 | 2013-08-01 | 9,150 | 3,732,980 | 0 |
| Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
|---|---|---|---|---|---|---|---|---|
| 1 | Water | Anadarko | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 83.9655 | 31,151,700.0 |
| Bio-Clear 5000 | Trican Well Service | Biocide | 2,2-dibromo-3-nitrilopropionamide | 10222-01-2 | 10 | 0.0047613 | 1766.47 | |
| Polyethylene glycol | 25322-68-3 | 70 | 0.0333291 | 12365.3 | ||||
| AI-7NR | Trican Well Service | Corrosion Inhibitor | Prop-2-yn-1-ol | 107-19-7 | 1 | 0.00002069 | 7.677 | |
| Sand (Proppant) | Trican Well Service | Proppant | Quartz | 14808-60-7 | 99 | 15.202 | 5,640,030.0 | |
| Hexamethylenetretramine | 100-97-0 | 1 | 0.153556 | 56970 | ||||
| Hydrochloric Acid (7.5%) | Trican Well Service | Acidizing | Hydrochloric Acid | 7647-01-0 | 7.5 | 0.0403523 | 14970.9 | |
| Bio-Clear 1000 | Trican Well Service | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 98 | 0.0001083 | 40.18 | |
| FEAC-20 | Trican Well Service | Iron Control | Acetic Acid | 64-19-7 | 50 | 0.00244183 | 905.933 | |
| Citric Acid | 77-92-9 | 30 | 0.0014651 | 543.56 | ||||
| FR-15 | Trican Well Service | Friction Reducer | Paraffinic, Naphthenic Solvent | 64742-47-8 | 25 | 0.0215536 | 7996.51 | |
| Proprietary Amide | Proprietary | 2.5 | 0.00215536 | 799.651 |
For data sources see[5]
| Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
|---|---|---|---|---|---|---|---|
| 2012 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2013 | ANADARKO E&P ONSHORE LLC | 270,874.00 | 36 | 0.00 | 0 | 0.00 | 0 |
| 2014 | ANADARKO E&P ONSHORE LLC | 1,579,379.00 | 274 | 0.00 | 0 | 0.00 | 0 |
| 2015 | ANADARKO E&P ONSHORE LLC | 1,337,748.00 | 307 | 0.00 | 0 | 0.00 | 0 |
| 2016 | ANADARKO E&P ONSHORE LLC | 988,957.00 | 365 | 0.00 | 0 | 0.00 | 0 |
| 2017 | ARD OPR LLC | 495,124.34 | 347 | 0.00 | 0 | 0.00 | 0 |
| 2018 | ARD OPR LLC | 606,620.09 | 365 | 0.00 | 0 | 0.00 | 0 |
| 2019 | ARD OPR LLC | 479,470.05 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
| Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
|---|---|---|---|---|---|
| 2013 | ANADARKO E&P ONSHORE LLC | Drill Cuttings | 564.22 Tons | LANDFILL | 301626 |
| 2013 | ANADARKO E&P ONSHORE LLC | Drill Cuttings | 931.92 Tons | LANDFILL | 100955 |
| 2013 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 2,525.42 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2014 | ANADARKO E&P ONSHORE LLC | Fracturing Fluid Waste | 720.00 Tons | LANDFILL | 301358 |
| 2014 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 3,486.17 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2015 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 309.19 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
| 2015 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 1,921.08 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 130.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
| 2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 55.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW005 |
| 2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 24.00 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
| 2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 112.08 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
| 2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 245.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
| 2017 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 46.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
| 2017 | ARD OPR LLC | Produced Fluid | 10.47 Bbl | REUSE (AT WELL PAD) | |
| 2018 | ARD OPR LLC | Produced Fluid | 356.66 Bbl | REUSE (AT WELL PAD) | |
| 2019 | ARD OPR LLC | Produced Fluid | 161.53 Bbl | REUSE (AT WELL PAD) | |
| 2019 | ARD OPR LLC | Produced Fluid | 0.68 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
For data sources see[7]
| Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|---|
| 2141276 | Primary Facility | 2013-02-20 | Routine/Complete Inspection | No Violations Noted | |
| 2141545 | Primary Facility | 2013-02-20 | Drilling/Alteration | No Violations Noted | |
| 2148272 | Primary Facility | 2013-03-07 | Routine/Complete Inspection | No Violations Noted | precision 528 onsite drilling the 2GH no violations |
| 2153358 | Primary Facility | 2013-04-02 | Drilling/Alteration | No Violations Noted | |
| 2166498 | Primary Facility | 2013-05-13 | Drilling/Alteration | No Violations Noted | |
| 2188291 | Primary Facility | 2013-07-31 | Routine/Partial Inspection | Violation(s) Noted | |
| 2206894 | Primary Facility | 2013-09-24 | Routine/Complete Inspection | No Violations Noted | |
| 2465245 | Primary Facility | 2016-03-04 | Routine/Complete Inspection | No Violations Noted | Routine Inspection of wells in production. No violations noted at this time. |
| 2521862 | Primary Facility | 2016-09-13 | Routine/Complete Inspection | No Violations Noted | Arrived @ 14:18. Weather: windy with some clouds. There were four producing wells and three wells on inactive status at this location. This was a routine inspection during which no personnel were onsite.
A-204H, in production. Some water in cellar, no bubbling. Top gauge: ¿ 1000 psi, (digital, difficult to see), 5-1/2”: 1060 psi, 8-5/8” x 5-1/2” 0 psi (digital), 11-3/4” x 8-5/8”: shut-in. A-203H, in production. Some water in cellar, no bubbling. Top gauge: ¿ 1000 psi, (digital, difficult to see), 5-1/2”: 1012 psi, 8-5/8” x 5-1/2” 0 psi (digital), 11-3/4” x 8-5/8”: shut-in. A-202H, in production. Some water in cellar, no bubbling. Top gauge: ¿ 1000 psi, (digital, difficult to see), 5-1/2”: 1070psi, 8-5/8” x 5-1/2” 0 psi (digital), 11-3/4” x 8-5/8”: shut-in. A-201H, in production. Some water in cellar, no bubbling. Top gauge: ¿ 1000 psi, (digital, difficult to see), 5-1/2”: 1061 psi, 8-5/8” x 5-1/2” 0 psi (digital), 11-3/4” x 8-5/8”: shut-in. |
| 2561099 | Primary Facility | 2017-02-10 | Routine/Complete Inspection | No Violations Noted | Routine Inspection; 2/10/2017.
I entered the site at 14:46 and found the Terry D Litzelman A 201-204H (081-21088, 081-21089, 081-21090, 081, 21091) in production. The Terry D Litzelman A 1-3GH (081-21095, 081-21096, 081-21097) were granted inactive status on 12/9/2014. ESX11-081-0003 expired on 2/6/2016. Currently, the site remains at the originally permitted size, has not been restored or reduced, and no PCSM (Post Construction Stormwater Management) has been implemented on the site. The Terry Litzelman B pad was part of the ESCGP but was never constructed. The most recent update to the well site restoration assessment Anadarko provided on 12/22/2016 indicates infiltration testing is planned for 2017 and the site will be re-permitted in 2018. I recommend re-permitting the site to comply with PCSM requirements and implementing that plan including well site restoration. No Violations Noted. |
| 2784589 | Primary Facility | 2018-10-04 | Routine/Complete Inspection | No Violations Noted | Fours wells staged for production phase. Four each water separators. Dump lines wrapped in insulating blanket. No leaks detected from production equipment. Methanol tanks located near well heads. No violations noted. |
| Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
|---|---|---|---|---|---|---|
| 2188291 | 674183 | 07/31/2013 | 2013-07-31 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | |
| 2188291 | 674184 | 07/31/2013 | 2013-07-31 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | |
| 2188291 | 674185 | 07/31/2013 | 2013-07-31 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | |
| 2188291 | 674186 | 07/31/2013 | 2013-07-31 | 201E - Failure to comply with terms and conditions of permit | Environmental Health & Safety | 3218.2 (a): Containment not sufficiently impervious to contain a spill |
| Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
|---|---|---|---|---|---|---|---|
| 674183 | 300468 | NOV - Notice of Violation | Comply/Closed | 2013-11-06 | |||
| 674184 | 300468 | NOV - Notice of Violation | Comply/Closed | 2013-11-06 | |||
| 674185 | 300468 | NOV - Notice of Violation | Comply/Closed | 2013-11-06 | |||
| 674186 | 300468 | NOV - Notice of Violation | Comply/Closed | 2013-11-06 |
For data sources see[8]