If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
| Well ID: 37-081-21154 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.422764,"lon":-77.127164,"icon":""}]} |
| Country: United States | |
| State: Pennsylvania | |
| County: Lycoming | |
| Municipality: Cogan House Township | |
| Operator Name: ARD OPR LLC | |
| Well Pad ID: 145418 | |
| Farm/Lease Name: LYCOMING H&FC A 1H | |
| License Status: Plugged and Abandoned | |
| Spud Date: 2013-05-01 | |
| Permit Date: 2013-04-19 | |
| Well Type: GAS | |
| Unconventional Well: Y | |
| Configuration: Horizontal Well | |
| Conservation: No | |
| Latitude: 41.422764 | |
| Longitude: -77.127164 |
| Date | Event |
|---|---|
| 2013-04-19 | New Permit Application |
| 2013-05-01 | Drilling Completion |
| 2013-05-01 | Performed Spud Operation |
| 2013-07-01 | New Permit Application |
| 2014-11-23 | Begin Plugging |
| 2014-11-23 | Finished Plugging |
| 2016-07-14 | NEWLY DRILLED |
For data sources see[4]
| Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
|---|---|---|---|---|---|---|---|
| 2013 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2014 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2015 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2016 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2017 | ARD OPR LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
| Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
|---|---|---|---|---|---|
| 2013 | ANADARKO E&P ONSHORE LLC | Drill Cuttings | 80.55 Tons | LANDFILL | 301626 |
| 2013 | ANADARKO E&P ONSHORE LLC | Drill Cuttings | 23.67 Tons | LANDFILL | 100955 |
| 2013 | ANADARKO E&P ONSHORE LLC | Fracturing Fluid Waste | 120.00 Tons | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
| 2015 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 1,247.29 Bbl | REUSE OTHER THAN ROAD SPREADING |
For data sources see[6]
| Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|---|
| 2198896 | Primary Facility | 2013-08-26 | Routine/Complete Inspection | No Violations Noted | |
| 2206905 | Primary Facility | 2013-09-24 | Routine/Complete Inspection | No Violations Noted | |
| 2593761 | Primary Facility | 2017-04-27 | Routine/Complete Inspection | No Violations Noted | Rutine inspection of unconvnetional well. Well is plugged. No plugging certificate on file. No violations noted at time of inspection. |
| 2707843 | Primary Facility | 2018-03-15 | Routine/Complete Inspection | No Violations Noted | A routine inspection of this unconventional well pad was conducted March 15, 2018. The purpose of inspection was to verify the 1-H is plugged because no plugging certificate was found and the well currently holds an Active status. At the time of inspection, the 1H appeared to be a plugged 20" conductor only, with a plate welded across the top and a 2" candy cane vent as a plugged well monument with marker. No obvious issues were observed. There were 3 producing wells on the pad. I conducted a visual inspection of these three producing wells and did not discover any obvious issues.
Please submit a plugging certificate for the 1-H if it is in fact permanently plugged at your convenience. |
| 2775334 | Primary Facility | 2018-09-14 | Routine/Complete Inspection | No Violations Noted | Four wells staged for production phase. Four each water separators. Sand separator before GPU. No leaks detected from production equipment. Methanol tank located near well heads. No violations noted. |
| 2856716 | Primary Facility | 2019-03-21 | Routine/Complete Inspection | No Violations Noted | Three wells staged for production. One plugged well (081-21154). Three GPUs within polyurethane/foam containment. No leaks detected from production equipment. Methanol tanks and foam tanks staged near well heads. No leaks. |
For data sources see[7]