Well ID: 37-081-21352 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.330578,"lon":-76.964906,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Eldred Township | |
Operator Name: INFLECTION ENERGY (PA) LLC | |
Well Pad ID: 149806 | |
Farm/Lease Name: CHAAPEL MOUNTAIN BENNETT 1 | |
License Status: | |
Spud Date: | |
Permit Date: 2013-11-01 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.330578 | |
Longitude: -76.964906 |
Date | Event |
---|---|
2013-11-01 | New Permit Application |
2014-01-09 | Performed Spud Operation |
2018-05-30 | MOD |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | INFLECTION ENERGY (PA) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | INFLECTION ENERGY (PA) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | INFLECTION ENERGY (PA) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | INFLECTION ENERGY (PA) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2019 | INFLECTION ENERGY (PA) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2019 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 120.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2236467 | Primary Facility | 2014-01-09 | Routine/Partial Inspection | No Violations Noted | Dallas Morris 25 onsite waiting for conductor to be drilled. No Vio. |
2274687 | Primary Facility | 2014-05-21 | Complaint Inspection | No Violations Noted | On 5/21/2014 Ms. Renner and I inspected the site. Severe erosion was noted on the cut slope of the infiltration basin and at the inlet swale entering the basin. In addition, erosion was noted in the roadside swale above the basin. Based on the erosion I recommend re-evaluating the basin design itself in addition to possibly adding additional cross culverts to reduce the volume of stormwater entering the basin. |
2276596 | Primary Facility | 2014-05-28 | Incident- Response to Accident or Event | No Violations Noted | 5/26/2014: Tanya Montefusco (Inflection) reported a synthetic oil-based mud spill from the Flexrig 354 after encountering gas while drilling the Bush Hill Bennett 2 (081-21351). The displaced drill mud was sprayed across the well pad, onto the soil stockpile, and on some trees. |
2421104 | Primary Facility | 2015-10-27 | Routine/Complete Inspection | No Violations Noted | Weather calm, cloudy, cool. Arrived @ 15:50. There were 4 wells spudded on the site, 3 production tanks, 1production unit, and a bank of 4 Baker tanks on containment.Chaapel Mountain Bennett 1H: Well head capped, cellar water-filled. One large bubble was observed approximately every 16-20 seconds on the side of the well head closest to the BHB2. The bubbling was coming from the blind capping the casing head, according to Fidurko, who said it would be tightened up on 11/2/15. |
2427713 | Primary Facility | 2015-11-23 | Routine/Complete Inspection | No Violations Noted | Weather sunny, cold and windy. Arrived @ 11:35. There were 4 wells spudded on the site, 3 production tanks, 1production unit, and a bank of 4 Baker tanks on containment. |
2438591 | Primary Facility | 2016-01-04 | Complaint Inspection | No Violations Noted | Weather sunny, cold and windy. Arrived @ 13:20. There were 4 wells spudded on the site, 3 production tanks, 1production unit, and a bank of 4 Baker tanks on containment.
Chaapel Mountain Bennett 1H: Well head capped, cellar empty. Annular vent were monitored for combustible gas using an Altair 5X gas meter calibrated on 01/04/2016. No gas was detected. There were no violations at this time. Left location @ 14:30. |
2452048 | Primary Facility | 2016-02-18 | Drilling/Alteration | No Violations Noted | CMB 1H:
Pressure prior to blow-down 1250 psi. As Brian opened the 9-5/8” casing vent the well emitted gas and some mud and made a vigorous roaring sound that did not stabilize during the inspection. Previously on 2/9/15, the well took 3 hours to blow down from a starting pressure of 1250 psi. As Ken’s equipment could not measure flows > 20l/min (0.7 ft3 /min). The blow-down was terminated @ 12:42, approximately 1.5 hours. Left location @ 12:45. |
2454733 | Primary Facility | 2016-03-01 | Routine/Complete Inspection | No Violations Noted | Weather sunny, spring-like. Arrived @ 13:25. There were 4 wells spudded on the site, 3 production tanks, 1production unit, and a bank of 4 Baker tanks on containment. A water truck was leaving the site as I arrived.
Chaapel Mountain Bennett 1H: Water and ice in the cellar, no bubbling. This well was top-holed (01/2014). There are three annular vents: one, 1”-diameter 20” x 13-3/8” vent and two, 2” 13-3/8” x 9-5/8” vents. The vents are clearly labeled. They were monitored for combustible gas using an Altair 5X meter calibrated on 03/01/16. 20” x 13-3/8”: 0% methane 13-3/8” x 9-5/8”: 0% methane Left location @ 14:00. There were no violations associated with this inspection. |
2469576 | Primary Facility | 2016-03-30 | Routine/Complete Inspection | No Violations Noted | |
2471752 | Primary Facility | 2016-04-04 | Routine/Complete Inspection | No Violations Noted | Weather sunny, cold. Arrived @ 11:30. There were 4 wells spudded on the site, 3 production tanks, 1production unit, and a bank of 4 Baker tanks on containment.
Chaapel Mountain Bennett 1H: Water in the cellar, no bubbling. This well was top-holed (01/2014). There are three annular vents: one, 1”-diameter 20” x 13-3/8” vent and two, 2” 13-3/8” x 9-5/8” vents. The vents are clearly labeled. At the time of my inspection a wireline crew was onsite to open the 2” valve in a plug at 1700’ in the Bush Hill Bennett 1H. Left @ 15:45 |
2472550 | Primary Facility | 2016-04-05 | Routine/Complete Inspection | No Violations Noted | Weather: sunny and cold. Arrived @ 7:30
There are 4 wells on this pad. Three are top-holed only: Bush Hill Bennett 1H, Chaapel Mt. Bennett 1H & 3H. The BHB 1H was being blown down at the time of my inspection. |
2472552 | Primary Facility | 2016-04-06 | Routine/Complete Inspection | No Violations Noted | BHB1 being blown down |
2472554 | Primary Facility | 2016-04-07 | Routine/Complete Inspection | No Violations Noted | |
2479855 | Primary Facility | 2016-04-26 | Routine/Complete Inspection | No Violations Noted | Arrived @ 16:00. Weather: sunny, humid. The BHB 1H was shut-in on 4/25/16. The two other top-holed wells: Chaapel Mountain Bennett 1H and Chaapel Mountain Bennett 3H have been shut-in, but pressure monitoring for these two wells also began on 4/25/16 prior to a pressure and flow monitoring study. BHB 1H: shut-in. Intermediate casing pressure: 1600 psi, (0-3000 psi analog gauge). BHB 2H in production. Chaapel Mountain Bennett 1H: Intermediate casing pressure: 1070 psi (0-3000 psi analog gauge). Chappel Mountain Bennett 3H: Intermediate casing pressure: 920 psi (0-3000 psi analog gauge).
Plan is to begin flowing the wells on 4/28/16 and begin measuring rates. |
2492579 | Primary Facility | 2016-06-09 | Drilling/Alteration | No Violations Noted | Arrived @ 10:45. Weather: sunny, pleasant. Personnel on site: Brian Twigg (Inflection), Matt Caldwell (Moody). The purpose of this inspection was to check on the monitoring/flaring arrangements for the 3 top-holed wells on location: BHB 1H, CMB 1H, and CMB 3H, following receipt of Inflection’s update on Intermediate Casing Pressure management for these wells. At the time of inspection: BHB 1H was flaring, and CMB 1H and CMB 3H were shut-in, with intermediate hut-in pressures at 200 psi. Continuous pressure loggers were fitted to the intermediate casings of each top-holed well. Beginning 6/14 @ 6:00, the BHB 1H would also be shut-in. Pressures on the CMB 1H and CMB 3H would be monitored to determine whether a hydraulic connection between the BHB 1H and the CMB wells exists at depth. No violations were observed during this inspection. Left location @ 11:20. |
2535035 | Primary Facility | 2016-11-02 | Routine/Complete Inspection | No Violations Noted | Well top-holed, no gas on annuli. |
2570817 | Primary Facility | 2017-03-13 | Administrative/File Review | Violation(s) Noted | Administrative Inspection Record created for the purpose of entering Enforcement Record for failure to plug an abandoned well.
VIOL closed 5/30/2018 due to permit mod being issued for this well as a result of VIOLS cited in IR #2570817 and ENF #351602 for failing to drill the well in the permitted surface hole location. Because the well has an active well permit, the VIOL for failure to plug an abandoned well was ACO. |
2605617 | Primary Facility | 2017-06-20 | Administrative/File Review | Violation(s) Noted | Administrative Inspection entered for the purpose of entering an Enforcement Record (NOV).
VIOLS closed (CRCTD) 5/30/2018 upon issuance of permit modification. |
2818996 | Primary Facility | 2018-12-26 | Routine/Complete Inspection | No Violations Noted | One well staged for production (2H). Three additional wells spudded, but not staged for production. These wells are recommended for in active status application with the Department.
One GPU within containment. No violations taken at this time. Additionally, a fresh water impoundment is on location with maintaind free board. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2570817 | 780462 | 2017-03-13 | 2018-05-30 | 78a91(a) | Environmental Health & Safety | The Chaapel Mountain Bennett 1 well was spud January 9, 2014 under the authorization of well permit number 081-21352. The well permit for 081-21352 expired November 1, 2014. The well record indicates the Well was drilled to 5,554 feet (Total Measured Depth) on January 20, 2014. The well remains t |
2605617 | 788434 | 2017-06-20 | 2018-05-30 | OGA3211(F1) | Administrative | Well was intentionally drilled at a Surface Hole Location (SHL) other than the approved SHL on the well permit, resulting in the actual SHL being approximately 193 feet from the permitted SHL. |
2605617 | 788435 | 2017-06-20 | 2018-05-30 | 78a12 | Administrative | The well was not drilled in accordance with the approved well permit. The actual SHL is approximately 193 feet from the permitted SHL. |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
780462 | 351602 | NOV - Notice of Violation | 2018-05-30 | ||||
788434 | 354424 | NOV - Notice of Violation | 2018-05-30 | ||||
788435 | 354424 | NOV - Notice of Violation | 2018-05-30 |
For data sources see[7]