Well ID: 37-111-20207 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.129834,"lon":-78.951635,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Somerset | |
Municipality: Quemahoning Township | |
Operator Name: ENERVEST OPR LLC | |
Well Pad ID: | |
Farm/Lease Name: LEACH UNIT 1 | |
License Status: ACTIVE | |
Spud Date: | |
Permit Date: 1994-06-07 | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 40.129834 | |
Longitude: -78.951635 |
Date | Event |
---|---|
1994-06-07 | New Permit Application |
1994-07-22 | Performed Spud Operation |
1994-08-12 | Drilling Completion |
1995-05-02 | Perforation |
1997-02-28 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2002 | BELDEN & BLAKE CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2005 | BELDEN & BLAKE CORP | 33484 | 365 | 0 | 365 | 0.00 | 0 |
2006 | BELDEN & BLAKE CORP | 29729.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2007 | BELDEN & BLAKE CORP | 24,243.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2008 | BELDEN & BLAKE CORP | 20377.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2009 | BELDEN & BLAKE CORP | 12,656.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2010 | BELDEN & BLAKE CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | BELDEN & BLAKE CORP | 3.00 | 91 | 0.00 | 0 | 0.00 | 0 |
2012 | BELDEN & BLAKE CORP | 7,213.68 | 61 | 0.00 | 0 | 0.00 | 0 |
2013 | ENERVEST OPR LLC | 61,444.51 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | ENERVEST OPR LLC | 26,692.42 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | ENERVEST OPR LLC | 22,007.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | ENERVEST OPR LLC | 24,575.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | ENERVEST OPR LLC | 18,983.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | ENERVEST OPR LLC | 4,655.00 | 132 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2005 | BELDEN & BLAKE CORP | Brine | 1,525.00 Bbl | Other | 37-111-20059 |
2012 | BELDEN & BLAKE CORP | Produced Fluid | 18.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095273 |
2013 | ENERVEST OPR LLC | Produced Fluid | 3,401.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
2013 | ENERVEST OPR LLC | Produced Fluid | 277.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NW003 |
2013 | ENERVEST OPR LLC | Produced Fluid | 3,401.00 Bbl | CENT WASTE TRT FAC NPDES | PA0095273 |
2014 | ENERVEST OPR LLC | Produced Fluid | 3,144.25 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
2014 | ENERVEST OPR LLC | Produced Fluid | 3,144.25 Bbl | CENT WASTE TRT FAC NPDES | PA0095273 |
2014 | ENERVEST OPR LLC | Produced Fluid | 392.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NW003 |
2014 | ENERVEST OPR LLC | Produced Fluid | 30.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0101508 |
2014 | ENERVEST OPR LLC | Produced Fluid | 30 Bbl | CENT WASTE TRT FAC NPDES | PA0101508 |
2015 | ENERVEST OPR LLC | Produced Fluid | 325 Bbl | CENT WASTE TRT FAC NPDES | PA0095273 |
2015 | ENERVEST OPR LLC | Produced Fluid | 325.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
2016 | ENERVEST OPR LLC | Produced Fluid | 400.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
2016 | ENERVEST OPR LLC | Produced Fluid | 400 Bbl | CENT WASTE TRT FAC NPDES | PA0095273 |
2017 | ENERVEST OPR LLC | Produced Fluid | 330.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | ENERVEST OPR LLC | Produced Fluid | 1,850.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2018 | ENERVEST OPR LLC | Produced Fluid | 100.00 Bbl | REUSE AT A CONVENTIONAL WELL SITE IN PA | |
2018 | ENERVEST OPR LLC | Produced Fluid | 900.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1793911 | Primary Facility | 2009-04-15 | Drilling/Alteration | Violation(s) Noted | Well location located by GPS unit. Date of Permit is 7/7/94. According to records, well drilled 8/12/94 to a depth of 9,436 ft from grade. No WACR report submitted to DEP. During inspection, well tag was not present at the well head or production equipment. The well was completed with 13" flange well assembly retrofitted to 4 gate valves, fluid relief valve and reduced to 2 inch production lines. Pressure readings on the dual pen data logging unit showed 200 psi on outside pressure and inconsistent readings of 25 psi on inside pressure. Site also contained separator, heating unit and brine tank (near well head and abandoned tank near road). The valves were located in the on position. Possible signs of fluid leakage occurring around the abandoned tank wellhead. |
1809398 | Primary Facility | 2009-07-01 | Compliance Evaluation | No Violations Noted | During inspection, well tag was present at the production equipment. Shut off valves missing from well head assembly causing gas release at the wellhead. Called Everest about the release of gas. Pressure readings on the dual pen data logging unit showed 270 psi/10 psi. Site also contained separator, heating unit and brine tank (near well head and abandoned tank near road) and new brine tank present to replace the abandoned tank. Four 55 gal drums remain near production equipment and two 55 gal drums near well head. No E&S or IW issues at the site. |
2165381 | Primary Facility | 2013-05-13 | Complaint Inspection | No Violations Noted | |
2165700 | Primary Facility | 2013-05-10 | Routine/Complete Inspection | No Violations Noted | |
2372519 | Primary Facility | 2015-05-12 | Routine/Complete Inspection | No Violations Noted | System was shut off upon arrival to the site. No flow from gas well located on top of hill was occurring. According to Enervest personnel, a valve near the demister had a leak from abrasion of sand in the gas line. Gas was released during the morning hours. On 5/13/15, the valve was replaced and well was turned back on. No release of fluids from the valve occurred. |
2669294 | Primary Facility | 2017-12-11 | Routine/Complete Inspection | No Violations Noted | Well tag present. Well head moderate/heavy corroded. Production line appears frozen. Meter showing production. Additional equipment onsite. Eg. two tanks. Dep request additional equipment removed. |
682898 | Primary Facility | 1994-08-03 | Routine/Complete Inspection | No Violations Noted | DRILLING; E&S, PITS OK |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1793911 | 561673 | 04/15/2009 | 2009-04-15 | 201TAG - Failure to install, in a permanent manner, the permit number on a completed well | Administrative |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
561673 | 245454 | NOV - Notice of Violation | Comply/Closed | 2009-07-01 |
For data sources see[7]