Well ID: 37-113-20011 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.554994,"lon":-76.467794,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Sullivan | |
Municipality: Cherry Township | |
Operator Name: CHESAPEAKE APPALACHIA LLC | |
Well Pad ID: 148120 | |
Farm/Lease Name: COVEYTOWN | |
License Status: | |
Spud Date: 2010-09-20 | |
Permit Date: 2010-08-03 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.554994 | |
Longitude: -76.467794 |
Date | Event |
---|---|
2010-08-03 | New Permit Application |
2010-09-14 | Performed Spud Operation |
2010-10-23 | Drilling Completion |
2010-11-22 | Perforation |
2014-12-19 | DEVIATED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CHESAPEAKE APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CHESAPEAKE APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHESAPEAKE APPALACHIA LLC | 67,773.00 | 9 | 0.00 | 0 | 0.00 | 0 |
2013 | CHESAPEAKE APPALACHIA LLC | 2,225,582.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | CHESAPEAKE APPALACHIA LLC | 1,003,052.00 | 359 | 0.00 | 0 | 0.00 | 0 |
2015 | CHESAPEAKE APPALACHIA LLC | 662,247.00 | 336 | 0.00 | 0 | 0.00 | 0 |
2016 | CHESAPEAKE APPALACHIA LLC | 686,269.00 | 329 | 0.00 | 0 | 0.00 | 0 |
2017 | CHESAPEAKE APPALACHIA LLC | 577,010.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHESAPEAKE APPALACHIA LLC | 497,417.00 | 361 | 0.00 | 0 | 0.00 | 0 |
2019 | CHESAPEAKE APPALACHIA LLC | 664,062.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | CHESAPEAKE APPALACHIA LLC | Produced Fluid | 650.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CHESAPEAKE APPALACHIA LLC | Produced Fluid | 6,167.48 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHESAPEAKE APPALACHIA LLC | Produced Fluid | 1,934.15 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CHESAPEAKE APPALACHIA LLC | Produced Fluid | 61.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2015 | CHESAPEAKE APPALACHIA LLC | Produced Fluid | 581.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHESAPEAKE APPALACHIA LLC | Other Oil & Gas Wastes | 25.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC008 |
2016 | CHESAPEAKE APPALACHIA LLC | Produced Fluid | 916.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CHESAPEAKE APPALACHIA LLC | Other Oil & Gas Wastes | 43.00 Bbl | REUSE (AT WELL PAD) | |
2018 | CHESAPEAKE APPALACHIA LLC | Produced Fluid | 212.00 Bbl | REUSE (AT WELL PAD) | |
2019 | CHESAPEAKE APPALACHIA LLC | Produced Fluid | 120.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2019 | CHESAPEAKE APPALACHIA LLC | Waste Water Treatment Sludge | 3.08 Tons | LANDFILL | 301626 |
2019 | CHESAPEAKE APPALACHIA LLC | Produced Fluid | 120.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2019 | CHESAPEAKE APPALACHIA LLC | Other Oil & Gas Wastes | 45.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC008 |
2019 | CHESAPEAKE APPALACHIA LLC | Produced Fluid | 110.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC008 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1919110 | Primary Facility | 2010-10-06 | Drilling/Alteration | No Violations Noted | ran 575 ft 13 3/8 casing 15 bbl cement returned to surface. ran 2481 ft 9 5/8 casing 17 bbl return cement to surface. |
1921306 | Primary Facility | 2010-10-20 | Routine/Complete Inspection | No Violations Noted | |
1977724 | Primary Facility | 2011-06-02 | Routine/Complete Inspection | No Violations Noted | 5H is drilled - cellar is filled with water, no bubbles 2 other cellars site looks good |
2013864 | Primary Facility | 2011-10-25 | Routine/Partial Inspection | No Violations Noted | Walked perimeter with Chris Hughes, great veg. cover. E&S controls can be removed. |
2029336 | Primary Facility | 2011-12-23 | Routine/Complete Inspection | No Violations Noted | |
2031141 | Primary Facility | 2012-01-03 | Follow-up Inspection | No Violations Noted | |
2057647 | Primary Facility | 2012-04-04 | Routine/Complete Inspection | No Violations Noted | |
2137248 | Primary Facility | 2012-10-01 | Follow-up Inspection | No Violations Noted | |
2465843 | Primary Facility | 2016-06-20 | Routine/Complete Inspection | No Violations Noted | : Arrived @ 13:20. Weather warm and sunny. E&S operations were ongoing at the periphery of the site. There was one producing well and a total of three slots on the pad. The cellars were full of water. There were no bubbles.
Coveytown 5H, in production. Water-filled cellar, no bubbling. 2 annular vents. 13-3/8” x 9-5/8” plumbed to the dump line, - 4.42 psi. 9-5/8” x 5-1/2”: shut in to gauge: 325.45 psi 5-1/2” casing: 355.56 psi 2-3/8” tubing: 1082.6 psi. Left @ 13:30
|
2503316 | Primary Facility | 2016-07-21 | Routine/Partial Inspection | No Violations Noted | Partial inspection to determine the status of installation of post-construction stormwater management (PCSM) BMPs. No Chesapeake representatives were present.
The PCSM BMPs have been installed as approved by the Department in February 2016 through the granting of a 2-year extension of time for site restoration. Erosion and sediment control BMPs and temporary stabilization have been installed, and no evidence of accelerated erosion or sedimentation was observed. No violations were cited during this inspection. |
2564821 | Primary Facility | 2017-02-24 | Administrative/File Review | No Violations Noted | No violations cited. |
2602541 | Primary Facility | 2017-06-07 | Routine/Complete Inspection | No Violations Noted | One well in production phase. One each sand and water separator. No leaks detected from production equipment. Site stable. Site meets the requirements of PA code 102.8. The Notice of Termination(NOT) is recognized as being true and correct. The site is recommended for an NOT approval. No violations noted. |
2704689 | Primary Facility | 2018-03-13 | Routine/Complete Inspection | No Violations Noted | One well staged for production phase. One each sand and water separator. No leaks detected from production equipment. No violations noted. |
2823663 | Primary Facility | 2019-01-08 | Routine/Complete Inspection | No Violations Noted | Arrived onsite for a routine inspection at 09:22; the weather was ~35°F and calm. The pad surface was ice covered due to freezing rain the previous night.
There was 1 properly tagged Marcellus well staged for production. There were 3 well cellars filled with ice; no bubbling was observed. There was 1 GPU and sand separator, and 2 produced water tanks onsite and in secondary containment. The sand separator and produced water tanks had visible flaking paint and corrosion (Photos 1, 2, 4). Overall, the site was well vegetated and no E&S issues were noted. The spillway for the western infiltration basin had riprap that slid to the bottom (Photo #3). Some pipeline was on the pad and it appeared that work was being completed at some point. It is recommended that production storage and equipment and PCSM features be inspected and repaired or replaced as needed. No violations noted at this time. |