If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-20183 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.733261,"lon":-75.886272,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Dimock Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 148408 | |
Farm/Lease Name: GESFORD 8H NW | |
License Status: | |
Spud Date: | |
Permit Date: 2009-06-25 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.733261 | |
Longitude: -75.886272 |
Date | Event |
---|---|
2009-06-25 | New Permit Application |
2009-07-10 | Performed Spud Operation |
2009-12-30 | Drilling Completion |
2010-10-01 | DEVIATED |
2012-02-19 | Perforation |
2012-11-04 | Performed Stimulation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-11-03 | 2012-11-03 | 6,863 | 5,932,248 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | KR-153SL | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.00534600 | ||
Water | 7732-18-5 | 80.00 | 0.02 | |||||
WFR-3B | Friction Reducer | Microparticle | 1.00 | 0.00144200 | ||||
Poly(oxy-1,2-ethanediyl), .alpha.,.alpha.'-[[(9Z)-9-octadecenylimino]di-2,1-ethanediyl]bis[.omega.-hydroxy - |
26635-93-8 | 5.00 | 0.00721000 | |||||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 50.00 | 0.07 | |||||
1,2-Propylene glycol | 57-55-6 | 15.00 | 0.02 | |||||
Water | 7732-18-5 | 40.00 | 0.05 | |||||
Ethoxylated C12-16 alcohols | 68551-12-2 | 15.00 | 0.02 | |||||
1,2-Propylene glycol | 57-55-6 | 40.00 | 0.05 | |||||
Water | Carrier/Base Fluid | 100.00 | 87.38 | |||||
PA Specific 40/70 mesh Sand | Sand - Bulk - Pennsylvania | Ferric oxide | 1309-37-1 | 0.10 | 0.01 | |||
Quartz | 14808-60-7 | 99.90 | 10.88 | |||||
Titanium dioxide | 13463-67-7 | 0.10 | 0.01 | |||||
Alumina | 1344-28-1 | 1.10 | 0.11 | |||||
Iron Acid 10M (12.6-18.0) | Acid Blend | Water | 7732-18-5 | 84.10 | 0.50 | |||
Proprietary | 1.20 | 0.00723300 | ||||||
Hydrochloric acid | 7647-01-0 | 15.80 | 0.09 | |||||
Super TSC LT | Paraffin & Scale Additive | Proprietary | 50.00 | 0.01 | ||||
Proprietary | 15.00 | 0.00375900 | ||||||
Water | 7732-18-5 | 60.00 | 0.01 | |||||
Acid Inhibitor 2 (AI-2) | Acid Corrosion Inhibitor | Isopropanol | 67-63-0 | 15.00 | 0.00015200 | |||
Poly(oxy-1,2-ethanediyl), alpha-(nonylphenyl)-omega-hydroxy-
, |
68412-54-4 | 13.00 | 0.00013200 | |||||
Propargyl alcohol | 107-19-7 | 20.00 | 0.00020300 | |||||
Tar bases, quinoline derivatives, benzyl chloride-quaternized |
72480-70-7 | 10.00 | 0.00010100 | |||||
Water | 7732-18-5 | 40.00 | 0.00040500 | |||||
Glycol Ethers | 20.00 | 0.00020300 | ||||||
PA Specific 100 mesh Sand | Sand - Bulk - Pennsylvania | Quartz | 14808-60-7 | 99.90 | 0.65 | |||
Alumina | 1344-28-1 | 1.10 | 0.00723500 | |||||
Titanium dioxide | 13463-67-7 | 0.10 | 0.00065800 | |||||
Ferric oxide | 1309-37-1 | 0.10 | 0.00065800 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2012-11-04 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2009 | CABOT OIL & GAS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | CABOT OIL & GAS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CABOT OIL & GAS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CABOT OIL & GAS CORP | 430,931.49 | 29 | 0.00 | 0 | 0.00 | 0 |
2013 | CABOT OIL & GAS CORP | 3,487,979.64 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | CABOT OIL & GAS CORP | 1,695,824.70 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | CABOT OIL & GAS CORP | 758,454.45 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CABOT OIL & GAS CORP | 1,075,960.30 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CABOT OIL & GAS CORP | 743,415.01 | 362 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 599,545.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 519,073.00 | 363 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2009 | CABOT OIL & GAS CORP | Drilling | 238.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0008451 |
2009 | CABOT OIL & GAS CORP | Drilling | 550.00 Bbl | Municipal Sewage Treatment Plant | PA0026034 |
2009 | CABOT OIL & GAS CORP | Drilling | 357.00 Bbl | Brine or Industrial Waste Treatment Plt | PAR9000009 |
2010 | CABOT OIL & GAS CORP | Basic Sediment | 1.85 Bbl | LANDFILL | 101534 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 51.00 Tons | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 101247 |
2010 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 168.60 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 14.40 Tons | LANDFILL | NY # 50S08 |
2010 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 4,065.00 Bbl | PUBLIC SEWAGE TREATMENT PLANT | PA0026034 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 83.10 Tons | LANDFILL | NY # 02S17 |
2010 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 101.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 1.10 Tons | LANDFILL | 100955 |
2010 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 1,097.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PAD085690592 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 83.10 Tons | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 8-4630-00010/00 |
2010 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 1,117.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2012 | CABOT OIL & GAS CORP | Basic Sediment | 9.00 Bbl | LANDFILL | THR029 |
2012 | CABOT OIL & GAS CORP | Fracturing Fluid Waste | 18.07 Tons | LANDFILL | THR029 |
2012 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 2,431.99 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE001 |
2012 | CABOT OIL & GAS CORP | Produced Fluid | 1,104.31 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 9,703.49 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 55.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE001 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 266.43 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 10.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 820.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE002 |
2014 | CABOT OIL & GAS CORP | Produced Fluid | 352.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 172.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 3.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 71.94 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 159.09 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 190.48 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 85.44 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018 | CABOT OIL & GAS CORP | Soil Contaminated by Oil & Gas Related Spills | 0.10 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301333 |
2018 | CABOT OIL & GAS CORP | Soil Contaminated by Oil | 0.10 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301333 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 98.53 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 147.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1813526 | Primary Facility | 2009-07-16 | Drilling/Alteration | No Violations Noted | At time of inspection drilling depth was at 2386'. Drilling was being performed with a 6-1/4 bit and projected depth was approximately 7000', at which point a larger rig will be brought in to complete the horizontal leg of the well. |
1833420 | Primary Facility | 2009-09-25 | Follow-up Inspection | No Violations Noted | An existing road was used to access the well site. The road and drill pad are stoned with limestone. The Site ID sign and E/S Plan were present at the entrance of the access road. |
1845069 | Primary Facility | 2009-11-10 | Follow-up Inspection | No Violations Noted | I inspected the well head for evidence of leakage. There was no standing water present in the cellar and therefore no visible bubbling observed. The well is currently shut in. |
1845633 | Primary Facility | 2009-11-04 | Routine/Complete Inspection | No Violations Noted | |
1849759 | Primary Facility | 2009-12-10 | Drilling/Alteration | No Violations Noted | Driling rig on site is Pioneer #61. At time of inspection, drilling depth was at kickoff point. The site was lined with plastic and bermed. The reserve pit had plenty of freeboard and the liner appeared to be in good condition. |
1864358 | Primary Facility | 2010-02-17 | Routine/Complete Inspection | No Violations Noted | Inspected well as per DEP COA issued to Operator. Operator planning to frac. Based in DEP inspection, no violations were observed. |
1960366 | Primary Facility | 2011-03-22 | Routine/Complete Inspection | No Violations Noted | |
2007829 | Primary Facility | 2011-09-02 | Routine/Complete Inspection | No Violations Noted | |
2119413 | Primary Facility | 2012-11-21 | Routine/Complete Inspection | No Violations Noted | well has been HF no observable anomolies |
2121479 | Primary Facility | 2012-11-08 | Incident- Response to Accident or Event | No Violations Noted | The Department was on site in response to a self-reported release. At the time of the inspection, the Department met with two Nahbors employees who were unaware of the release. The Department requested that they contact a Cabot employee concerning the inspection. The Department then met with Rafael Rodriguez (Completions Consultant- Cabot Oil & Gas). At this time Rafael explained that on 11/7/12 at 21:30 that a low pressure suction manifold on a pump truck came apart. It was reported that 20 bbl. were released to containment. It was initially determined that the release was “slick water” or freshwater mixed with friction reducer. This was noted to have occurred during Stage 12 pad. They are currently on Stage 15 of 17.Brody Webster of Cabot Oil & Gas arrived on site.Brody stated that they used a 100 bbl. vacuum truck to remove the liquid. A swath of sand was noted alongside the truck. |
2136391 | Primary Facility | 2013-02-05 | Routine/Complete Inspection | No Violations Noted | On site to do routine inspection of site. Two wells on site (8H and 4V). Both wells in production. Annuli vented. No pressure on gauge on backside of production. Well tag present. Site ID sign on place. Site has been restored. No violations observed. |
2139926 | Primary Facility | 2013-02-14 | Follow-up Inspection | No Violations Noted | On site to collect pressure reading and isotopic gas sample from annulus of well. DEP reps on site Steve Watson, Eric Rooney, and Gene Rickard. DEP met with John Smelko of Cabot. Selman reps on site to assist in collecting gas readings and splitting gas samples. Cabot shut in annulus on well at 9 am this morning. A digital pressure gauge was installed by Cabot on the 9 5/8 x 4 1/2" annulus. Pressure was 0 psi. Gague was removed and open vent flow was screened using Model 60. Reading was >5% combustible gas initially, but quickly bled down, and there was not enough gas present to collect a sample for isotopic analysis. After completion of sampling, Cabot re-connected vent line and locked vent open. |
2344425 | Primary Facility | 2014-02-11 | Complaint Inspection | No Violations Noted | The Department (Scott Kuchta-DEP WQS and I) was on site at the Gesford 4 & 8 well site in response to a complaint (2/7/15) concerning venting from the production tanks. At the time of the inspection, no venting was noted. The Department inspected the snow covered area around the tanks to check for indications of a fluid release. No evidence of released fluid was noted. |
2509189 | Primary Facility | 2016-08-04 | Complaint Inspection | No Violations Noted | At time of inspection, arrived on site at 12:05p.m. pertaining to a complaint called into the department about a backhoe and a dumpster being hauled onto the site and unknown activity. There was no activity on this site at time of inspection. There was no backhoe on site but there were two role off containers on the Castello J Pad 1 site. The marks on the entrance road indicated that the containers have recently been dropped off.
I left the site at 12:10p.m. |
2642894 | Primary Facility | 2017-10-02 | Site Restoration | No Violations Noted | I inspected the Gesford K, P4 site on October 2, 2017 to conduct a Notice of Termination (NOT) inspection.
The site was compact and well maintained. The access road was solid and stable. The pad surface was solid as well. The cut and fill slopes exceeded the 70% vegetative standard. On the east side of the pad, active agriculture was ongoing (field corn). There was no erosional issues apparent at the time of inspection. I recommend APPROVAL of this NOT. There were no violations noted. |
2672711 | Primary Facility | 2017-12-19 | Administrative/File Review | No Violations Noted | I approved a restoration report on December 19, 2017 for this well site. |
2677766 | Primary Facility | 2017-12-20 | Incident- Response to Accident or Event | Viol(s) Noted & Immediately Corrected | I arrived at the site in response to a reported spill of production fluid to the pad surface on 12-14-17. I was accompanied by Matt Shope, DEP O&G WQS. We met with Jordan Hoffman, lease operator of Cabot. The weather conditions were partly cloudy skies with a light breeze, occasional wind gusts, and temperatures in the mid 30's. I was first informed of the release on 12-19-17. I contacted Steve Watson, Environmental Health Specialist of Cabot Oil & Gas on 12-19-17 at 13:29 to acquire the specifics of the spill incident. He explained the following details regarding the spill. "The spill occurred at the Gesford 4 pad on State Route 3023 in Dimock. The above ground dump line froze as part of the Gesford 8H well. A flange fitting on the line separated spilling production fluid to the pad surface around 8:30 PM on 12/14/17. I reported the spill to the PADEP Emergency Response Team in NERO at 9:20 PM on 12/14/17. Soap sticks were added into the well on 12/13/17 to help lift the water in the gas since it is an old |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2677766 | 805147 | 2017-12-20 | 2017-12-20 | CSL 402(b) | Environmental Health & Safety | The violation is cited due to the 12-14-17 production fluid spill impacting the pad surface. |
2677766 | 805148 | 2017-12-20 | 2017-12-20 | 78A57(A)___ | Environmental Health & Safety | The violation is cited due to the 12-14-17 production fluid spill impacting the pad surface. |
2677766 | 805149 | 2017-12-20 | 2017-12-20 | SWMA 301 | Environmental Health & Safety | The violation is cited due to the 12-14-17 production fluid spill impacting the pad surface. |
For data sources see[9]