X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-20674

Well Details

Well ID: 37-115-20674
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: New Milford Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 149256
Farm/Lease Name: SCOTT 8H
License Status:
Spud Date:
Permit Date: 2011-10-04
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.836406
Longitude: -75.760189

For data sources see[1][2][3]

Well History

Date Event
2011-10-04 New Permit Application
2011-10-18 Performed Spud Operation
2012-03-03 Drilling Completion
2012-08-04 Perforation
2012-08-04 Performed Stimulation
2013-05-24 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-08-01 2012-08-01 6,725 4,979,940

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 SI-112 Clearwater International Scale Inhibitor Ethylene glycol 107-21-1 40.00 0.00433000
FRA-405 Clearwater International Friction Reducer Sodium chloride 7647-14-5 7.50 0.00071000
Ammonium chloride 12125-02-9 5.00 0.00047000
Distillates, petroleum, hydrotreated light 64742-47-8 27.50 0.00261000
Ethoxylated C12-16 alcohols 68551-12-2 5.00 0.00047000
StimLube Clearwater International Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.02
Southwestern Energy Sand Quartz 14808-60-7 100.00 7.47
H2O + Disolved Salts 100.00 91.68
AI-250 Clearwater International Acid Inhibitor Propargyl alcohol 107-19-7 40.00 0.00071000
2-Butoxyethanol 111-76-2 40.00 0.00071000
Isopropanol 67-63-0 40.00 0.00071000
Ethoxylated Nonylphenol 13.00 0.00023000
Biocide EC 6116A Nalco Biocide Hydrochloric acid 7647-01-0 15.00 0.10
Polyethylene glycol 25322-68-3 60.00 0.01
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.00 0.00684000
Dibromoacetonitrile 3252-43-5 5.00 0.00114000
15 HCl Nalco Acid Hydrochloric acid 7647-01-0 15.00 0.71
Biocide EC 6116A Nalco Acid
Southwestern Energy Water/Produced Water

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-08-04 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2012 SOUTHWESTERN ENERGY PROD CO 41,354.00 20 0.00 0 0.00 0
2013 SOUTHWESTERN ENERGY PROD CO 616,863.00 323 0.00 0 0.00 0
2014 SOUTHWESTERN ENERGY PROD CO 668,662.00 362 0.00 0 0.00 0
2015 SWN PROD CO LLC 502,613.00 365 0.00 0 0.00 0
2016 SWN PROD CO LLC 465,068.00 366 0.00 0 0.00 0
2017 SWN PROD CO LLC 250,824.00 345 0.00 0 0.00 0
2018 SWN PROD CO LLC 269,133.00 364 0.00 0 0.00 0
2019 SWN PROD CO LLC 288,320.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SOUTHWESTERN ENERGY PROD CO Drill Cuttings 36.00 Tons LANDFILL NY STATE #32S11
2012 SOUTHWESTERN ENERGY PROD CO Fracturing Fluid Waste 512.95 Tons LANDFILL 101247
2012 SOUTHWESTERN ENERGY PROD CO Drill Cuttings 765.75 Tons LANDFILL THR029
2013 SOUTHWESTERN ENERGY PROD CO Produced Fluid 1,587.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SOUTHWESTERN ENERGY PROD CO Drill Cuttings 148.18 Tons LANDFILL 101247
2013 SOUTHWESTERN ENERGY PROD CO Fracturing Fluid Waste 4.74 Tons LANDFILL 101247
2013 SOUTHWESTERN ENERGY PROD CO Fracing Fluid Waste 2,545.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SOUTHWESTERN ENERGY PROD CO Produced Fluid 3,200.00 Bbl CENT WASTE TRT FAC NPDES PA0254185
2013 SOUTHWESTERN ENERGY PROD CO Produced Fluid 3,200.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0254185
2014 SOUTHWESTERN ENERGY PROD CO Produced Fluid 590.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWN PROD CO LLC Produced Fluid 279.60 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Other Oil & Gas Wastes 24.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Drill Cuttings 104.49 Tons LANDFILL 101247
2016 SWN PROD CO LLC Produced Fluid 371.66 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Produced Fluid 1,205.67 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Other Oil & Gas Wastes 18.33 Bbl REUSE (AT WELL PAD)
2017 SWN PROD CO LLC Other Oil & Gas Wastes 1,084.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 380.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Synthetic Liner Materials 0.86 Tons LANDFILL 100933
2017 SWN PROD CO LLC Other Oil & Gas Wastes 537.00 Bbl REUSE OTHER THAN ROAD SPREADING
2018 SWN PROD CO LLC Produced Fluid 331.67 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid 31.00 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 37.50 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Other Oil & Gas Wastes 135.90 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 54.99 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Produced Fluid 221.49 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Other Oil & Gas Wastes 85.83 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 18.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC035

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2014451 Primary Facility 2011-10-25 Drilling/Alteration No Violations Noted Falcon Rig 16. Durrently drilling on air. Depth at 200'. Drillers log on site and up to date. 20 " set at 46'. 13 3/8 will be set at 638'. Will be running FIT after running surface casing. Secondary containment in place. Some tears by rolloffs. operator will repair. Also need to berm up back of location. Operator indicated the berms are in process of being built and will be finished once all equipment is moved onto containment. No violations observed.
2022395 Primary Facility 2011-11-22 Follow-up Inspection Pending Follow up inspection. Operator reported bubbling in cellar. Well is currently shut in. Floor of cellar is poured concrete. The top of conductor and surface string are below the concrete floor. A small steady stream of bubbling is present coming through the concrete floor approximately 3" away from 9 5/8" casing. Gauge on annulus reads 0 psi (3000 lb). No activity on site at time of inspection. Operator indicated they will be removing concrete and exposing tops of casing strings to identify source of bubbling.
2027611 Primary Facility 2011-11-30 Drilling/Alteration Pending DEP on site 14:00. Met with Mr. Bell - drilling supt. Bubbling reported in cellar of well while on site marking location of next well. On 11/2/11 an inspection of the well confirmed the bubbling in the cellar. The cellar floor at that time was cemented. The bubbling observed consisted of a small stream of steady bublng coming up through cement approximately 3" away from the 9 5/8" casing string. The 13 3/8" and 20" casing tops were under concrete at that time. Operator has removed cement and exposed tops of casings to identify source of bubbling. Operator indicated 3% LEL. CO2 ranged from 60 - 80 ppm. At time of this inspection a pump truck was on site and removed fluid from cellar. Observed minor bubbling on 9 5/8" annulus. Operator indicated a bond log will be run next week and all data collected will be shared with the DEP. No violation exists at this time. Operator has 30 days to correct the defect or present a plan to fix the defective cement.
2031216 Primary Facility 2012-01-03 Follow-up Inspection Pending Gas bubbling reported and confirmed on 9 x 13" annulus during previous inspection. Operator installed a packoff (cap) on well on 12/13/11. When installed, Operator reports no bubbling at that time. The annulus was shut in and pressure monitored. Pressure increased to a moximum of 22 psi after 48 hours. Operator issued repsonse letter with logs to DEP (rec'd 12/30/11). To date, there has been no reported gas leaking on 20 x 13" annulus. At this time, Operator is requesting to vent the leaking annulus and monitor the well without further immediate action. If there is any change to the status of the well, Operator will notify DEP immediately. Operator is planning to mobilixe rig onto the well to continue drilling oeprations in the near future. At this time, there is "pending" status on this well. There is evidence indicating a defective cement job on this string of casing. Operator is aware that future remediation efforts may be necessary.
2155666 Primary Facility 2013-04-04 Incident- Response to Accident or Event No Violations Noted
2355606 Primary Facility 2015-03-23 Routine/Complete Inspection No Violations Noted
2429304 Primary Facility 2015-12-01 Routine/Complete Inspection No Violations Noted
2472584 Primary Facility 2016-04-07 Routine/Complete Inspection No Violations Noted
2482634 Primary Facility 2016-05-10 Routine/Complete Inspection No Violations Noted
2497110 Primary Facility 2016-06-29 Routine/Complete Inspection No Violations Noted
2576739 Primary Facility 2017-03-27 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 12:45p.m.

There was a steel cage around the well. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge, the valve going to the production tank was closed. There was 606psi on the production casing and 588psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 13:40p.m.

2669163 Primary Facility 2017-12-08 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2768527 Primary Facility 2018-08-29 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[9]