X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-20985

Well Details

Well ID: 37-115-20985
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Harford Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 146325
Farm/Lease Name: DELUCIA R 2
License Status:
Spud Date:
Permit Date: 2012-09-25
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.795478
Longitude: -75.735135

For data sources see[1][2][3]

Well History

Date Event
2012-09-25 New Permit Application
2012-10-23 Performed Spud Operation
2013-01-26 Drilling Completion
2013-03-18 Perforation
2013-03-18 Performed Stimulation
2013-05-24 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-03-14 2013-03-17 7,099 5,709,270 332,673

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 CI-14 Baker Hughes Corrosion Inhibitor Polyoxyalkylenes Trade Secret 30 0.0002716 147.9
Propargyl Alcohol 107-19-7 5 0.00004530 24.65
Olefin Trade Secret 5 0.00004530 24.65
Fatty Acids Trade Secret 10 0.00009050 49.3
Sand, White, 40/70 Baker Hughes Proppant Crystalline Silica (Quartz) 14808-60-7 100 11.2589 6,132,000.0
HCl, 10.1 - 15% Baker Hughes Acidizing Water 7732-18-5 85 0.512986 279389
Hydrochloric Acid 7647-01-0 15 0.0905269 49304
Alpha 1427 Baker Hughes Biocide Ethanol 64-17-5 5 0.0011166 608.125
Quaternary Ammonium Compound 68424-85-1 5 0.0011166 608.125
Glutaraldehyde 111-30-8 30 0.0066995 3648.75
Didecyl Dimethyl Ammonium Chloride 7173-51-5 10 0.0022332 1216.25
Water Operator Carrier Water 7732-18-5 100 87.4032 47,602,800.0
Scaletrol 720 Baker Hughes Scale Inhibitor Ethylene Glycol 107-21-1 30 0.0044816 2440.81
Calcium Chloride 10043-52-4 5 0.0007469 406.801
FRW-18 Baker Hughes Friction Reducer Petroleum Distillates 64742-47-8 30 0.0166146 9048.89
Other Chemicals Sodium Chloride 7647-14-5 0 0.00000450 2.4408
Polyacrylate Trade Secret 0 0.0029877 1627.2
Modified Thiorea Polymer 68527-49-1 0 0.00006340 34.51
Water 7732-18-5 0 0.049093 26737.7
Hydrochloric Acid 7647-01-0 0 0.00000910 4.93
Poly (acrylamide-co-acrylic acid) Trade Secret 0 0.0166146 9048.89
Methanol 67-56-1 0 0.0009052 493
Formaldehyde 50-00-0 0 0.00000910 4.93
Potassium Chloride 7447-40-7 0 0.00000750 4.068
Ethoxylated Alcohol Trade Secret 0 0.0011076 603.259
Salt Trade Secret 0 0.0027691 1508.15
Sorbitan Monooleate Trade Secret 0 0.0027691 1508.15
Ferrotrol 300L Baker Hughes Iron Control Citric Acid 77-92-9 60 0.0007871 428.695
Sand, White, 100 mesh Baker Hughes Proppant Crystalline Silica (Quartz) 14808-60-7 100 0.623722 339700

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2013-03-18 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2013 CABOT OIL & GAS CORP 1,119,532.00 84 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 2,232,137.41 358 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 1,195,759.88 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 932,522.70 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 699,471.15 365 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 562,231.00 261 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 645,045.00 335 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CABOT OIL & GAS CORP Drilling Fluid Waste 660.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Drill Cuttings 217.48 Tons LANDFILL 101247
2012 CABOT OIL & GAS CORP Drill Cuttings 302.62 Tons LANDFILL THR029
2012 CABOT OIL & GAS CORP Drilling Fluid Waste 151.17 Bbl LANDFILL THR029
2013 CABOT OIL & GAS CORP Drill Cuttings 74.56 Tons LANDFILL 101247
2013 CABOT OIL & GAS CORP Fracing Fluid Waste 759.33 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2013 CABOT OIL & GAS CORP Produced Fluid 2,381.49 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Fracing Fluid Waste 6,951.14 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Drilling Fluid Waste 1,568.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Drill Cuttings 425.85 Tons LANDFILL THR029
2014 CABOT OIL & GAS CORP Produced Fluid 2,674.29 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 839.11 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 7.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 262.38 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 233.49 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 73.65 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017 CABOT OIL & GAS CORP Produced Fluid 197.64 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Produced Fluid 170.48 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Synthetic Liner Materials 0.96 Tons LANDFILL 101247
2018 CABOT OIL & GAS CORP Produced Fluid 427.46 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 145.83 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Synthetic Liner Materials 9.44 Tons LANDFILL 101247
2019 CABOT OIL & GAS CORP Produced Fluid 357.72 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 821.30 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2019 CABOT OIL & GAS CORP Waste Water Treatment Sludge 1.49 Tons REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2135151 Primary Facility 2013-01-29 Drilling/Alteration No Violations Noted Well complete. Patterson 538. Reviewed well file-cement reports show good returns on both surface and intermediate. Set packer on intermediate at 1560'. Drillers log on site and up to date. Permit on site. Site ID sign in place with proper information posted. 5 /12 set at 11,000' TOC estimated 2106'.Intermediate set at 2331" No violations observed.
2364410 Primary Facility 2015-04-27 Routine/Partial Inspection No Violations Noted
2476519 Primary Facility 2016-04-20 Routine/Complete Inspection No Violations Noted
2486938 Primary Facility 2016-05-23 Routine/Complete Inspection No Violations Noted
2502690 Primary Facility 2016-07-18 Routine/Complete Inspection No Violations Noted
2537550 Primary Facility 2016-11-16 Routine/Complete Inspection No Violations Noted On 11/16/16, the Department conducted an inspection of the Cabot Delucia R well site located in Harford Township, Susquehanna County. The inspection was conducted in response to a complaint that a nearby spring had dried up and that it was suspected that the cause of the diminution was the installation of natural gas related infrastructure located up gradient of the spring. Today’s inspection found that the pad layout is per plan. Good, permanent stabilization present on entire site. Standing water located on the pad in the near vicinity of the well heads was tested for conductivity. Readings were within a 600 to 700 microsiemen range. All 3 wells associated with this pad have been drilled and placed into production since 2013. No violations noted.
2582535 Primary Facility 2017-04-12 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:35p.m.

The cellar was about a quarter full of water with no bubbling noticed. The (13x9) annulus vent pipe was open and venting into the production tank, the (9x5) annulus vent pipe was open and venting into the production tank. There was 502psi on the production casing. I took a walk around the location and there were no obvious concerns noticed. I left the site at 14:05p.m.

2684077 Primary Facility 2018-01-11 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The (20x13) annulus was below the water level and there was no bubbling noticed. The (13x9) and (9x5) annuli vent pipes were connected together and venting to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[9]

References