37-115-20990

Well Details

Well ID: 37-115-20990
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Gibson Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 147298
Farm/Lease Name: T SALANSKY 4
License Status:
Spud Date:
Permit Date: 2012-09-26
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.751851
Longitude: -75.599935

For data sources see[1][2][3]

Well History

Date Event
2012-09-26 New Permit Application
2012-10-02 Performed Spud Operation
2012-12-08 Drilling Completion
2012-12-17 Perforation
2013-02-02 Performed Stimulation
2014-02-13 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-02-01 2013-02-01 7,475 7,961,184

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 CS-500 SI FTSI Scale Inhibitor Ethylene Glycol 107-21-1 10.0 0.00296
40/70 White FTSI Proppant Crystalline Silica NA 100.0 10.50506
FRW-200 FTSI Friction Reducer Petroleum Distillate Hydrotrea 64742-47-8 26.0 0.02308
ICI-3240 FTSI Biocide Dazomet 533-74-4 24.0 0.00719
HCl, 10.1 - 15 FTSI Acidizing Hydrochloric Acid 7647-01-0 15.0 0.07858
Water Operator Carrier Water 7732-18-5 100.0 88.23283
CI-150 FTSI Corrosion Inhibitor Isopropanol 67-63-0 60.0 0.00058
100 Mesh FTSI Proppant Crystalline Silica NA 100.0 0.58715
Quaternary ammonium compound Proprietary 10.0 0.0001
Sodium Hydroxide 1310-73-2 4.0 0.0012
Organic Amineresin Salt Proprietary 30.0 0.00029
Dimethylformamide 68-12-2 10.0 0.0001
Water 7732-18-5 85.0 0.44531
Aromatic aldehyde Proprietary 10.0 0.0001
FE-100L FTSI Iron Control Product Citric Acid 77-92-9 55.0 0.00095

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2013-02-02 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2013 CABOT OIL & GAS CORP 2,024,594.69 244 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 1,688,291.17 355 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 1,129,906.61 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 1,005,618.13 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 808,037.10 365 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 655,851.00 356 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 592,431.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CABOT OIL & GAS CORP Drilling Fluid Waste 1,210.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Drill Cuttings 718.90 Tons LANDFILL 101247
2012 CABOT OIL & GAS CORP Drill Cuttings 717.52 Tons LANDFILL THR029
2012 CABOT OIL & GAS CORP Drilling Fluid Waste 420.01 Bbl LANDFILL THR029
2013 CABOT OIL & GAS CORP Produced Fluid 3,139.67 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Fracing Fluid Waste 1,394.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2013 CABOT OIL & GAS CORP Produced Fluid 2,378.31 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Fracing Fluid Waste 8,759.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2014 CABOT OIL & GAS CORP Produced Fluid 1,688.83 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Produced Fluid 97.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2015 CABOT OIL & GAS CORP Produced Fluid 816.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 6.79 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 35.67 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE004
2016 CABOT OIL & GAS CORP Produced Fluid 479.77 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 202.68 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 103.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 193.96 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017 CABOT OIL & GAS CORP Produced Fluid 307.01 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018 CABOT OIL & GAS CORP Synthetic Liner Materials 1.19 Tons LANDFILL 101247
2018 CABOT OIL & GAS CORP Produced Fluid 415.94 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 151.10 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 55.16 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 447.04 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2125313 Primary Facility 2012-12-12 Drilling/Alteration No Violations Noted In process of moving Patterson 263. Well drilled. Checked cellar- no issues observed. WEll tag present. Note: Ryan Klemish to be on site to follow up on diesel spill reported. Any ciolations cited will be in his inspection report.
2351606 Primary Facility 2015-02-26 Routine/Complete Inspection No Violations Noted
2463348 Primary Facility 2016-03-10 Routine/Complete Inspection No Violations Noted
2493187 Primary Facility 2016-06-15 Routine/Complete Inspection No Violations Noted
2569373 Primary Facility 2017-03-02 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:55p.m.

The cellar had water at the bottom with no bubbling noticed. The (13x9) annulus vent pipe was open and venting into the production tank, the (9x5) annulus vent pipe was open and venting into the production tank. There was 464psi on the production casing. I took a walk around the location and there were no obvious concerns noticed. I left the site at 14:30p.m.

2655000 Primary Facility 2017-10-26 Site Restoration No Violations Noted This inspection was conducted to confirm Cabot's assessment that the project meets the minimum requirements for permanent stabilization. The Departments determination is that the site meets the requirements for permit termination.
2663825 Primary Facility 2017-11-17 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar had water at the bottom and there was no bubbling noticed. The (13x9) and (9x5) annuli were connected together a venting to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2694185 Primary Facility 2018-02-12 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. No E&S issues noted. No violations noted.
2716316 Primary Facility 2018-04-09 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. No E&S issues identified. No violations noted.
2736077 Primary Facility 2018-05-22 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. No E&S issues were observed. No violations noted.
2759680 Primary Facility 2018-08-02 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 5' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. The (13x9) and (9x5) annuli vent pipes were connected together and going to a production tank. There was new containment around the wells and two trailers with 2 3/8 tubing. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2856372 Primary Facility 2019-03-19 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. Overall the site appears to have good stabilization. No E&S issues identified. No violations noted.

For data sources see[9]