X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-21714

Well Details

Well ID: 37-115-21714
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Jessup Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 151032
Farm/Lease Name: GRASAVAGE E 4
License Status:
Spud Date:
Permit Date: 2014-03-19
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.794978
Longitude: -75.977978

For data sources see[1][2][3]

Well History

Date Event
2014-03-19 New Permit Application
2014-06-01 Performed Spud Operation
2014-07-28 Drilling Completion
2014-09-20 Perforation
2014-11-02 Performed Stimulation
2015-01-29 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-10-15 2014-11-08 6,162 14,474,300 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 CS-500 SI FTSI Scale inhibitor Ethylene glycol 107-21-1 10 0.0024947 3406.49
Sodium Polyacrylate 9003-04-7 5 0.00124735 1703.24
Sodium chloride 7647-14-5 6 0.00149682 2043.89
Acrylic Polymer Proprietary 0 0 0
Water 7732-18-5 55 0.0137209 18735.7
Hydrochloric Acid (HCl) FTSI Acid Hydrogen Chloride 7647-01-0 37 0.108243 147804
Water 7732-18-5 63 0.184305 251666
100 Mesh Sand FTSI proppant Silica, Quartz 14808-60-7 100 0.592771 809420
FE-100L FTSI Iron control Citric acid 77-92-9 55 0.000518153 707.53
Water 7732-18-5 60 0.000565258 771.85
40/70 White FTSI proppant Silica, Quartz 14808-60-7 100 10.5723 14,436,300.0
CI-150 FTSI Acid Corrosion Inhibitor Alkylene Oxide Block Polymer Proprietary 10 0.00005225 71.34
Water 7732-18-5 5 0.00002612 35.67
Aliphatic alcohol Proprietary 0.1 0.00000052 0.71
Fatty Acid Salt Proprietary 0.1 0.00000052 0.71
Fatty Acid Proprietary 0.1 0.00000052 0.71
Quaternary ammonium compound Proprietary 10 0.00005225 71.34
Isopropanol 67-63-0 30 0.000156735 214.02
Organic amine resin salt Proprietary 30 0.000156735 214.02
Dimethylformamide 68-12-2 10 0.00005225 71.34
Diethylene glycol 111-46-6 1 0.00000522 7.13
Aromatic aldehyde Proprietary 10 0.00005225 71.34
Ethylene Glycol 107-21-1 30 0.000156735 214.02
FRW-200 FTSI Friction reducer Ammonium Chloride 12125-02-9 12 0.0103506 14133.6
Ammonium Acrylate 10604-69-0 0.5 0.000431274 588.9
Water 7732-18-5 48 0.0414023 56534.3
Dewaxed heavy paraffinic 64742-65-0 1.5 0.00129382 1766.7
Isopropanol 67-63-0 0.3 0.000258764 353.34
Polyethylene glycol monooleate 9004-96-0 3 0.00258764 3533.39
Surfactant Proprietary 7 0.00603783 8244.58
Sorbitan Monooleate 1338-43-8 3 0.00258764 3533.39
Alcohols (C10-C16), ethoxylated 68002-97-1 4 0.00345019 4711.19
Acrylamide P/W acrylic acid, ammonium salt 26100-47-0 25 0.0215637 29444.9
Alkyloxypolyethyleneoxyethanol 84133-50-6 1 0.000862548 1177.8
Sorbitol Tetraoleate 61723-83-9 2 0.0017251 2355.59
Acrylamide 79-06-1 0.1 0.00008625 117.78
Copolymer of acrylamide and sodium acrylate 25987-30-8 33 0.0284641 38867.3
Petroleum distillate hydrotreated light 64742-47-8 26 0.0224262 30622.7
Hydrotreated heavy paraffinic 64742-54-7 5 0.00431274 5888.98
Alcohols (C12-C14), ethoxylated 68439-50-9 4 0.00345019 4711.19
Alcohols (C12-C16), ethoxylated 68551-12-2 4 0.00345019 4711.19
Water Operator Carrier Water 7732-18-5 100 88.4046 120,715,000.0
ICI-3240 FTSI Biocide Sodium Hydroxide 1310-73-2 23 0.00578439 7898.5
Dazomet (Tetrahydro-3, 5-dimethyl-2H-1,
3, 5-thiadiazine-2-thione.
533-74-4 24 0.00603588 8241.91
Water 7732-18-5 55 0.0138322 18887.7

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-11-02 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 CABOT OIL & GAS CORP 422,089.34 32 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 4,227,898.92 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 2,994,727.81 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 2,168,036.60 365 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 1,289,549.00 314 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 895,351.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 CABOT OIL & GAS CORP Produced Fluid 1,102.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 3,959.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Drill Cuttings 1,476.19 Tons LANDFILL 101247
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 22,042.28 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 9,208.48 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 5.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 366.23 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 639.20 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2016 CABOT OIL & GAS CORP Produced Fluid 1,307.92 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 1,086.53 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Produced Fluid 109.47 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 25.87 Bbl REUSE (AT WELL PAD)
2018 CABOT OIL & GAS CORP Produced Fluid 20.60 Bbl REUSE (AT WELL PAD)
2018 CABOT OIL & GAS CORP Produced Fluid 868.41 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 387.06 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 619.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Waste Water Treatment Sludge 2.20 Tons REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2265930 Primary Facility 2014-04-28 Preoperation Inspection No Violations Noted
2284356 Primary Facility 2014-06-24 Drilling/Alteration No Violations Noted Conductor set
2296112 Primary Facility 2014-07-25 Drilling/Alteration No Violations Noted Currently at 14720'
2357460 Primary Facility 2015-03-31 Routine/Complete Inspection No Violations Noted The Department was on site to conduct a routine complete inspection of the Grasavage E. Well site. The area was partially snow covered and there were no erosional issues apparent at this time, and the site was stable. The most recent E&S Inspection was on 3/26/15. The wells associated with this site are as follows:
2365487 Primary Facility 2015-04-29 Routine/Complete Inspection No Violations Noted
2466939 Primary Facility 2016-03-22 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 10:45 a.m., the cellar had water at the bottom with no bubbling noticed, the (13x9) vent pipe was open and venting to a tank, the (9x5) vent pipe was open and venting to a tank, there was about 650psi on the production casing. I took a walk around the location and everything looked OK.

I left the site at 11:30 a.m.

2475037 Primary Facility 2016-03-21 Routine/Complete Inspection No Violations Noted The Department was on site to conduct a routine complete inspection of the Grasavage E. Well site (ESX13-115-0105). There were no erosional issues apparent at this time, and the site was stable.

The wells associated with this site are as follows: 115-21715 115-21714 115-21713 115-21712 115-21711

There were no violations.

If there are any questions, please feel free to contact me at (570)346-5539

2526029 Primary Facility 2016-09-22 Routine/Partial Inspection No Violations Noted
2545882 Primary Facility 2016-12-16 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:10a.m., the cellar was about half full of ice and snow. The (13x9) vent pipe was open and venting into a small plastic tank, the (9x5) vent pipe was open and venting into a small plastic tank. There was 613psi on the production casing. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 11:45a.m.

2556289 Primary Facility 2017-01-25 Follow-up Inspection No Violations Noted The Department was on site at the Grasavage, E. Well Site located at 2993 East Rush Street Jessup Township, Susquehanna County for a Follow-Up Inspection to the Department’s 9/22/2016 inspection. I reviewed the E&S Inspection Log and found that Mike Brilla, TEC conducted the most recent inspection, which was noted as a post precipitation inspection, on 1/25/2016.

During this inspection, the Department inspected the sediment trap that was found to not have sufficient stabilization during the previous inspection. At this time, the sediment trap was filled with water and ice but erosion control blanket was visible through some areas.

The well site was about 90% snow covered during the inspection. No obvious issues were found.

2634885 Primary Facility 2017-09-11 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. All the annuli vent pipes were venting into the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2714126 Primary Facility 2018-04-03 Site Restoration No Violations Noted I inspected the Grasavage E Well Site .The cut and fill slopes were stable and had adequate vegetation in excess of 70% perennial cover. There were no erosional issues observed. The wells were properly labeled.

The wells associated with this site are as follows: 115-21712 115-21713 115-21714 115-21715.

There were no violations noted.

2728775 Primary Facility 2018-05-11 Routine/Complete Inspection No Violations Noted I performed a RTNC inspection of the Grasavage well site. The wells associated with this site are as follows: 115-21712, 115-21713, 115-21714, 115-21716.

These wells were properly labeled.

The cut slope was well vegetated. It was stable. The fill slope was stable and very well vegetated. There were no erosional issues noted.

The pad surface and access road were stable and solid.

There were no violations observed.

2743658 Primary Facility 2018-06-20 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 1' below grade in the cellar and there was no bubbling noticed. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank at 24% LEL and 4% methane. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2819783 Primary Facility 2018-12-21 Routine/Complete Inspection No Violations Noted I performed a RTNC inspection of the Grasavage well site. The weather at the time of inspection was above 60 degrees F. The sky was partly sunny and it had rained earlier in the morning. The well pad surface was damp but otherwise solid.
    The access road and pad surface were both solid and stable.  The pad surface was recently made smaller and the vegetation around the edge was doing well, as it was lush and thick.
    The cut and fill slopes were in good shape with no rills or erosional issues.  The slopes were well vegetated and stable. 
    The wells were clearly and properly labeled. 
    The infiltration basins were well vegetated and appeared to be performing their jobs.
    There were no violations noted.
2839652 Primary Facility 2019-02-07 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water and ice .5' below grade in the cellar and there was no bubbling noticed. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank with a MSA Altair 5X multi gas detector that was calibrated on 2/5/19. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[9]

References