X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-21774

Well Details

Well ID: 37-115-21774
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: New Milford Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 148583
Farm/Lease Name: INNES NORTH 2H
License Status:
Spud Date:
Permit Date: 2014-06-06
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.831967
Longitude: -75.732403

For data sources see[1][2][3]

Well History

Date Event
2014-06-06 New Permit Application
2014-07-03 Performed Spud Operation
2014-09-29 Drilling Completion
2014-11-23 Perforation
2014-11-23 Performed Stimulation
2015-03-18 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-11-23 2014-11-29 6,847 8,285,970 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FRA-407 Weatherford Friction Reducer Petroleum Distillates 64742-47-8 40 0.00680752 5925.03
Ammonium Acetate 631-61-8 5 0.00085094 740.629
K Bac -1020 WST Biocide Polyethylene glycol 25322-68-3 60 0.00623276 5424.78
2,2-Diobrom-3nirilopropionamide 10222-01-2 20 0.00207759 1808.26
Sand Keane Sand Crystalline Silica, Quartz 14808-60-7 100 16.4471 14,315,000.0
FRA-405 Clearwater Friction Reducer Sodium Chloride 7647-14-5 10 0.00629107 5475.53
Alcohols, C-12-16, Ethoxylated 68551-12-2 7 0.00440375 3832.87
Petroleum Distillates 64742-47-8 40 0.0251643 21902.1
Ammonium Chloride 12125-02-9 7 0.00440375 3832.87
AI-600 Weatherford Acid Inhibitor Tar bases, quinoline derivs, benzyl chloride-quaternized 72480-70-7 13 0.000200472 174.484
Ethoxylated Nonylphenol 68412-54-4 10 0.000154209 134.219
Triethyl Phosphate 78-40-0 7 0.000107946 93.953
N,N-Dimethylformamide 68-12-2 40 0.000616837 536.874
Cinnamaldehyde 104-55-2 10 0.000154209 134.219
2-Butoxyethanol 111-76-2 7 0.000107946 93.953
Ethylene Glycol 107-21-1 60 0.000925256 805.311
Isopropyl Alchol 67-63-0 7 0.000107946 93.953
EC6486 Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00273909 2384.01
Water SWN Water / Produced Water H2O + Disolved Salts 7732-18-5 100 82.8351 72,096,800.0
15% HCl Reagent Acid HCL 7647-01-0 15 0.0925256 80531.1

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-11-23 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2015 SWN PROD CO LLC 2,615,073.00 330 0.00 0 0.00 0
2016 SWN PROD CO LLC 2,139,730.00 366 0.00 0 0.00 0
2017 SWN PROD CO LLC 1,060,610.00 365 0.00 0 0.00 0
2018 SWN PROD CO LLC 1,025,843.00 365 0.00 0 0.00 0
2019 SWN PROD CO LLC 931,486.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 SOUTHWESTERN ENERGY PROD CO Fracing Fluid Waste 1,370.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SOUTHWESTERN ENERGY PROD CO Drill Cuttings 1,221.03 Tons LANDFILL 101247
2015 SWN PROD CO LLC Fracing Fluid Waste 3,124.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWN PROD CO LLC Drill Cuttings 37.03 Tons LANDFILL 101247
2015 SWN PROD CO LLC Fracturing Fluid Waste 12.34 Tons LANDFILL THR029
2015 SWN PROD CO LLC Produced Fluid 4,655.71 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid 1,223.74 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Other Oil & Gas Wastes 14.29 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 2,293.30 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid 1,120.02 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid 238.13 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 278.44 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Other Oil & Gas Wastes 117.12 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 284.28 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Other Oil & Gas Wastes 22.45 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 37.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC035
2019 SWN PROD CO LLC Produced Fluid 674.85 Bbl SURFACE IMPOUNDMENT 95-16-65420-013

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2285175 Primary Facility 2014-07-09 Drilling/Alteration No Violations Noted Well spud 7/3/14 - conductor set. Rig expected to move on location 7/11/14
2299610 Primary Facility 2014-08-26 Routine/Complete Inspection No Violations Noted Falcon Rig# 18 is the active drilling rig on the location. Laddie Pendergraft is the company man on location. The current drilling depth is (4,740) feet. I observed a relatively large hole in the composite mats surveying the drilling rig containment system. Beneath the composite mats are layers of felt and a (40) mil HDPE liner. Mr. Pendergraft said the hole will be repaired today. The secondary containment as part of the drilling rig and associated equipment appeared to be in good condition as well as did the production equipment secondary containment. The fluid levels in the drill cuttings containers and Keystone Landfill containers did not exceed the (2)’ freeboard requirement of Title 25, Env. Protection, Pa. code 78.56.
2300071 Primary Facility 2014-08-28 Drilling/Alteration No Violations Noted
2307273 Primary Facility 2014-09-20 Routine/Complete Inspection No Violations Noted
2329094 Primary Facility 2014-12-15 Incident- Response to Accident or Event No Violations Noted Arrived at the site at 12:00 in response to reported spills of (3-5) barrels of flowback water and (50) gallons of antifreeze. Hydraulic fracturing operations were in progress. Keane Frac is the subcontractor conducting well stimulation (frac) procedures on Innes South 8H well. Justin Phillips, Health, Safety and Environmental Staff Coordinator Supervisor of SWN reported the estimated (3-5) barrel capacity spill flowback water spill that occurred on containment to the Department at 9:30 PM on 12/13/14. Chris Becker, Health, Safety & Environmental staff Coordinator of SWN reported the estimated (50) gallon antifreeze spill to the Department on 12/14/14 at 2:30 PM. There is no evidence the spills escaped secondary containment, no evidence of comprised liner integrity and no evidence of an impact to the pad surface in the general area where the spills occurred. Both spills occurred due to mechanical malfunction according to SWN.
2366976 Primary Facility 2015-05-01 Routine/Complete Inspection No Violations Noted
2452226 Primary Facility 2016-02-24 Routine/Complete Inspection No Violations Noted
2477417 Primary Facility 2016-04-22 Routine/Complete Inspection No Violations Noted
2488541 Primary Facility 2016-05-31 Routine/Complete Inspection No Violations Noted
2559655 Primary Facility 2017-02-06 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:20p.m., the cellar was set up with a plastic corrugated pipe around the well for inspection access; there was water above the surface casing with no bubbling noticed. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure and the valve going to the production tank was closed. There was 604psi on the production casing and 517psi on the production line. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 14:10p.m.

2652102 Primary Facility 2017-10-25 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was set up with a corrugated pipe around the well for inspection access. The (20x13) and (13x9) annuli were below the water level with no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2755266 Primary Facility 2018-07-24 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was set up with a corrugated pipe around the well for inspection access. There was water .5' below grade in the cellar and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[9]

References