If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-21774 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.831967,"lon":-75.732403,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: New Milford Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 148583 | |
Farm/Lease Name: INNES NORTH 2H | |
License Status: | |
Spud Date: | |
Permit Date: 2014-06-06 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.831967 | |
Longitude: -75.732403 |
Date | Event |
---|---|
2014-06-06 | New Permit Application |
2014-07-03 | Performed Spud Operation |
2014-09-29 | Drilling Completion |
2014-11-23 | Perforation |
2014-11-23 | Performed Stimulation |
2015-03-18 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2014-11-23 | 2014-11-29 | 6,847 | 8,285,970 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | FRA-407 | Weatherford | Friction Reducer | Petroleum Distillates | 64742-47-8 | 40 | 0.00680752 | 5925.03 |
Ammonium Acetate | 631-61-8 | 5 | 0.00085094 | 740.629 | ||||
K Bac -1020 | WST | Biocide | Polyethylene glycol | 25322-68-3 | 60 | 0.00623276 | 5424.78 | |
2,2-Diobrom-3nirilopropionamide | 10222-01-2 | 20 | 0.00207759 | 1808.26 | ||||
Sand | Keane | Sand | Crystalline Silica, Quartz | 14808-60-7 | 100 | 16.4471 | 14,315,000.0 | |
FRA-405 | Clearwater | Friction Reducer | Sodium Chloride | 7647-14-5 | 10 | 0.00629107 | 5475.53 | |
Alcohols, C-12-16, Ethoxylated | 68551-12-2 | 7 | 0.00440375 | 3832.87 | ||||
Petroleum Distillates | 64742-47-8 | 40 | 0.0251643 | 21902.1 | ||||
Ammonium Chloride | 12125-02-9 | 7 | 0.00440375 | 3832.87 | ||||
AI-600 | Weatherford | Acid Inhibitor | Tar bases, quinoline derivs, benzyl chloride-quaternized | 72480-70-7 | 13 | 0.000200472 | 174.484 | |
Ethoxylated Nonylphenol | 68412-54-4 | 10 | 0.000154209 | 134.219 | ||||
Triethyl Phosphate | 78-40-0 | 7 | 0.000107946 | 93.953 | ||||
N,N-Dimethylformamide | 68-12-2 | 40 | 0.000616837 | 536.874 | ||||
Cinnamaldehyde | 104-55-2 | 10 | 0.000154209 | 134.219 | ||||
2-Butoxyethanol | 111-76-2 | 7 | 0.000107946 | 93.953 | ||||
Ethylene Glycol | 107-21-1 | 60 | 0.000925256 | 805.311 | ||||
Isopropyl Alchol | 67-63-0 | 7 | 0.000107946 | 93.953 | ||||
EC6486 | Nalco | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.00273909 | 2384.01 | |
Water | SWN | Water / Produced Water | H2O + Disolved Salts | 7732-18-5 | 100 | 82.8351 | 72,096,800.0 | |
15% HCl | Reagent | Acid | HCL | 7647-01-0 | 15 | 0.0925256 | 80531.1 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2014-11-23 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | SWN PROD CO LLC | 2,615,073.00 | 330 | 0.00 | 0 | 0.00 | 0 |
2016 | SWN PROD CO LLC | 2,139,730.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | SWN PROD CO LLC | 1,060,610.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | SWN PROD CO LLC | 1,025,843.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | SWN PROD CO LLC | 931,486.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2014 | SOUTHWESTERN ENERGY PROD CO | Fracing Fluid Waste | 1,370.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | SOUTHWESTERN ENERGY PROD CO | Drill Cuttings | 1,221.03 Tons | LANDFILL | 101247 |
2015 | SWN PROD CO LLC | Fracing Fluid Waste | 3,124.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | SWN PROD CO LLC | Drill Cuttings | 37.03 Tons | LANDFILL | 101247 |
2015 | SWN PROD CO LLC | Fracturing Fluid Waste | 12.34 Tons | LANDFILL | THR029 |
2015 | SWN PROD CO LLC | Produced Fluid | 4,655.71 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWN PROD CO LLC | Produced Fluid | 1,223.74 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 14.29 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Produced Fluid | 2,293.30 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Produced Fluid | 1,120.02 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Produced Fluid | 238.13 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018 | SWN PROD CO LLC | Produced Fluid | 278.44 Bbl | REUSE (AT WELL PAD) | |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 117.12 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 284.28 Bbl | SURFACE IMPOUNDMENT | 826342 |
2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 22.45 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 37.14 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC035 |
2019 | SWN PROD CO LLC | Produced Fluid | 674.85 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2285175 | Primary Facility | 2014-07-09 | Drilling/Alteration | No Violations Noted | Well spud 7/3/14 - conductor set. Rig expected to move on location 7/11/14 |
2299610 | Primary Facility | 2014-08-26 | Routine/Complete Inspection | No Violations Noted | Falcon Rig# 18 is the active drilling rig on the location. Laddie Pendergraft is the company man on location. The current drilling depth is (4,740) feet. I observed a relatively large hole in the composite mats surveying the drilling rig containment system. Beneath the composite mats are layers of felt and a (40) mil HDPE liner. Mr. Pendergraft said the hole will be repaired today. The secondary containment as part of the drilling rig and associated equipment appeared to be in good condition as well as did the production equipment secondary containment. The fluid levels in the drill cuttings containers and Keystone Landfill containers did not exceed the (2)’ freeboard requirement of Title 25, Env. Protection, Pa. code 78.56. |
2300071 | Primary Facility | 2014-08-28 | Drilling/Alteration | No Violations Noted | |
2307273 | Primary Facility | 2014-09-20 | Routine/Complete Inspection | No Violations Noted | |
2329094 | Primary Facility | 2014-12-15 | Incident- Response to Accident or Event | No Violations Noted | Arrived at the site at 12:00 in response to reported spills of (3-5) barrels of flowback water and (50) gallons of antifreeze. Hydraulic fracturing operations were in progress. Keane Frac is the subcontractor conducting well stimulation (frac) procedures on Innes South 8H well. Justin Phillips, Health, Safety and Environmental Staff Coordinator Supervisor of SWN reported the estimated (3-5) barrel capacity spill flowback water spill that occurred on containment to the Department at 9:30 PM on 12/13/14. Chris Becker, Health, Safety & Environmental staff Coordinator of SWN reported the estimated (50) gallon antifreeze spill to the Department on 12/14/14 at 2:30 PM. There is no evidence the spills escaped secondary containment, no evidence of comprised liner integrity and no evidence of an impact to the pad surface in the general area where the spills occurred. Both spills occurred due to mechanical malfunction according to SWN. |
2366976 | Primary Facility | 2015-05-01 | Routine/Complete Inspection | No Violations Noted | |
2452226 | Primary Facility | 2016-02-24 | Routine/Complete Inspection | No Violations Noted | |
2477417 | Primary Facility | 2016-04-22 | Routine/Complete Inspection | No Violations Noted | |
2488541 | Primary Facility | 2016-05-31 | Routine/Complete Inspection | No Violations Noted | |
2559655 | Primary Facility | 2017-02-06 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 13:20p.m., the cellar was set up with a plastic corrugated pipe around the well for inspection access; there was water above the surface casing with no bubbling noticed. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure and the valve going to the production tank was closed. There was 604psi on the production casing and 517psi on the production line. I took a walk around the location and there were no obvious concerns noticed.
I left the site at 14:10p.m. |
2652102 | Primary Facility | 2017-10-25 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was set up with a corrugated pipe around the well for inspection access. The (20x13) and (13x9) annuli were below the water level with no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2755266 | Primary Facility | 2018-07-24 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was set up with a corrugated pipe around the well for inspection access. There was water .5' below grade in the cellar and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
For data sources see[9]