If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
| Well ID: 37-117-20687 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.693111,"lon":-77.121018,"icon":""}]} |
| Country: United States | |
| State: Pennsylvania | |
| County: Tioga | |
| Municipality: Bloss Township | |
| Operator Name: SENECA RESOURCES CO LLC | |
| Well Pad ID: 148210 | |
| Farm/Lease Name: DCNR 595 5H 50026 | |
| License Status: | |
| Spud Date: | |
| Permit Date: 2010-05-04 | |
| Well Type: GAS | |
| Unconventional Well: Y | |
| Configuration: Horizontal Well | |
| Conservation: No | |
| Latitude: 41.693111 | |
| Longitude: -77.121018 |
| Date | Event |
|---|---|
| 2010-05-04 | New Permit Application |
| 2011-08-05 | Performed Spud Operation |
| 2011-11-08 | Drilling Completion |
| 2012-01-30 | Perforation |
| 2014-02-12 | DEVIATED |
For data sources see[4]
| Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
|---|---|---|---|---|---|
| 1 | 2012-01-30 | 2012-01-30 | 7,816 | 3,662,736 |
| Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
|---|---|---|---|---|---|---|---|---|
| 1 | Proppant 30/50 Ottawa | Universal Well Services | Proppant | Quartz | 14808-60-7 | 100.00 | 5.78 | |
| 15 HydroChloric Acid | Universal Well Services | Acid | Hydrochloric acid | 7647-01-0 | 15.00 | 0.01 | ||
| 7.5 HydroChloric Acid | Universal Well Services | Acid | Hydrochloric acid | 7647-01-0 | 7.50 | 0.08 | ||
| Proppant 40/70 Ottawa | Universal Well Services | Proppant | Quartz | 14808-60-7 | 100.00 | 5.71 | ||
| BioRid 20L | Tetra | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.00194000 | ||
| Sodium bromide | 7647-15-6 | 15.00 | 0.00146000 | |||||
| Nalco Scale Inhibitor | Universal Well Services | Scale Inhibitor | Ethylene glycol | 107-21-1 | 30.00 | 0.00327000 | ||
| Unihib G | Universal Well Services | Corrosion Inhibitor | Diethylene glycol monobutyl ether | 112-34-5 | 50.00 | 0.00060000 | ||
| Resin Based Nonionic Inhibitor | 35.00 | 0.00042000 | ||||||
| Ethoxylated Alcohol | 35.00 | 0.00042000 | ||||||
| GB L | Universal Well Services | Breaker | Ethylene glycol | 107-21-1 | 60.00 | 0.00 | ||
| Iron Stabilizer II | Universal Well Services | Corrosion Inhibitor | Ethylene glycol | 107-21-1 | 30.00 | 0.00142000 | ||
| Unislik ST 50 | Universal Well Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 | ||
| Unigel 5F | Universal Well Services | Guar Gel Dry Add | Guar Gum | 100.00 | 0.00029000 |
For data sources see[5]
| Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
|---|---|---|---|---|---|---|---|
| 2010 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2011 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2012 | SENECA RESOURCES CO LLC | 612,721.00 | 284 | 0.00 | 0 | 0.00 | 0 |
| 2013 | SENECA RESOURCES CO LLC | 543,355.00 | 354 | 0.00 | 0 | 0.00 | 0 |
| 2014 | SENECA RESOURCES CO LLC | 387,452.30 | 363 | 0.00 | 0 | 0.00 | 0 |
| 2015 | SENECA RESOURCES CO LLC | 224,922.41 | 222 | 0.00 | 0 | 0.00 | 0 |
| 2016 | SENECA RESOURCES CO LLC | 147,537.57 | 97 | 0.00 | 0 | 0.00 | 0 |
| 2017 | SENECA RESOURCES CO LLC | 261,959.36 | 285 | 0.00 | 0 | 0.00 | 0 |
| 2018 | SENECA RESOURCES CO LLC | 220,340.10 | 340 | 0.00 | 0 | 0.00 | 0 |
| 2019 | SENECA RESOURCES CO LLC | 215,240.87 | 336 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
| Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
|---|---|---|---|---|---|
| 2011 | SENECA RESOURCES CO LLC | Drill Cuttings | 1,028.10 Tons | LANDFILL | 301358 |
| 2012 | SENECA RESOURCES CO LLC | Produced Fluid | 4,625.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2012 | SENECA RESOURCES CO LLC | Fracturing Fluid Waste | 281.79 Tons | LANDFILL | 301358 |
| 2012 | SENECA RESOURCES CO LLC | Fracing Fluid Waste | 3,519.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2012 | SENECA RESOURCES CO LLC | Fracturing Fluid Waste | 1.94 Tons | LANDFILL | 101397 |
| 2012 | SENECA RESOURCES CO LLC | Produced Fluid | 66.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
| 2013 | SENECA RESOURCES CO LLC | Produced Fluid | 2,884.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2013 | SENECA RESOURCES CO LLC | Produced Fluid | 36.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC012 |
| 2013 | SENECA RESOURCES CO LLC | Produced Fluid | 185.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC012 |
| 2014 | SENECA RESOURCES CO LLC | Produced Fluid | 1,883.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2015 | SENECA RESOURCES CO LLC | Produced Fluid | 112.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
| 2015 | SENECA RESOURCES CO LLC | Produced Fluid | 567.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2016 | SENECA RESOURCES CO LLC | Produced Fluid | 51.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2016 | SENECA RESOURCES CO LLC | Produced Fluid | 74.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
| 2016 | SENECA RESOURCES CO LLC | Produced Fluid | 15.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2017 | SENECA RESOURCES CO LLC | Produced Fluid | 255.39 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2017 | SENECA RESOURCES CO LLC | Produced Fluid | 180.40 Bbl | REUSE (AT WELL PAD) | |
| 2018 | SENECA RESOURCES CO LLC | Produced Fluid | 228.57 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 57.86 Bbl | REUSE (AT WELL PAD) | |
| 2018 | SENECA RESOURCES CO LLC | Produced Fluid | 278.57 Bbl | REUSE (AT WELL PAD) | |
| 2018 | SENECA RESOURCES CO LLC | Produced Fluid | 8.57 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
| 2019 | SENECA RESOURCES CO LLC | Produced Fluid | 87.85 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2019 | SENECA RESOURCES CO LLC | Produced Fluid | 30.00 Bbl | RESIDUAL WASTE TRANSFER FACILITY | WMGR123NC039 |
| 2019 | SENECA RESOURCES CO LLC | Produced Fluid | 17.14 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC003 |
| 2019 | SENECA RESOURCES CO LLC | Produced Fluid | 177.13 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
| Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|---|
| 1997228 | Primary Facility | 2011-08-10 | Routine/Partial Inspection | No Violations Noted | puddles outside impoundment 3.77 ms/cm. 401 violation cited on 2H |
| 2077533 | Primary Facility | 2012-06-20 | Follow-up Inspection | No Violations Noted | liner faulty, 10 mS/cm on ground |
| 2164868 | Primary Facility | 2013-04-30 | Routine/Complete Inspection | No Violations Noted | |
| 2370732 | Primary Facility | 2015-05-15 | Routine/Partial Inspection | No Violations Noted | 7 Marcellus Shale natural gas wells in production. |
| 2588005 | Primary Facility | 2017-04-24 | Routine/Partial Inspection | No Violations Noted | Electrical conductivity w/ an Oakton PCSTestr 35: Water in production tank containment--1.5 mS/ cm. Puddle on pad --0.60 mS/cm |
| 2588008 | Primary Facility | 2017-04-24 | Routine/Partial Inspection | No Violations Noted | Electrical conductivity w/ an Oakton PCSTestr 35: Water in production tank containment--1.5 mS/ cm. Puddle on pad --0.60 mS/cm |
| 2609708 | Primary Facility | 2017-06-28 | Routine/Partial Inspection | No Violations Noted | EC readings from liquid on site w Oakton PCSTestr 35 (mS/cm): 2 separator containments both--0.06, pad--0.26, production tank continment--1.4. Two workers are servicing equipment at the separators during this inspection. |
| 2820428 | Primary Facility | 2018-12-28 | Routine/Partial Inspection | No Violations Noted | I took electrical conductivity readings from pooled water on site with an Oakton PCSTestr 35. A puddle near the center of the Marcellus well pad returned 0.08 mS/cm.
Air temp: 45F JLP |
For data sources see[8]