X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-20965

Well Details

Well ID: 37-117-20965
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Duncan Township
Operator Name: EQT PROD CO
Well Pad ID: 149047
Farm/Lease Name: PHOENIX 590790
License Status:
Spud Date:
Permit Date: 2010-10-15
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.645303
Longitude: -77.290564

For data sources see[1][2][3]

Well History

Date Event
2010-10-15 New Permit Application
2011-04-16 Performed Spud Operation
2011-07-27 Drilling Completion
2011-11-05 Perforation
2012-12-11 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-01-25 2012-01-25 6,866 8,213,856

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 SP Breaker Halliburton Energy Services Oxidizing Breaker Sodium persulfate 7775-27-1 0.00030000
LP-65 Halliburton Energy Services Scale Inhibitor Ammonium chloride 12125-02-9 0.00240000
WG-36 GELLING AGENT Halliburton Energy Services Gelling Agent Naphtha, petroleum, hydrotreated heavy 64742-48-9 0.00
Guar gum 9000-30-0 0.00180000
BE-9 Biocide Halliburton Energy Services Biocide Tri-n-butyl tetradecyl phosphonium chloride 81741-28-8 0.00440000
GBW-30 BREAKER Halliburton Energy Services Enzyme Breaker Hemicellulase enzyme 9012-54-8 0.00
Hydrochloric Acid Halliburton Energy Services Corrosion Inhibitor
FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 0.02
Hydrochloric Acid Halliburton Energy Services 15 HCl Acid Methanol 67-56-1 0.00030000
Propargyl alcohol 107-19-7 0.00010000
Hydrochloric acid 7647-01-0 0.03
BA-40L Halliburton Energy Services Buffer Carbonic acid, dipotassium salt 584-08-7 0.00145000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 EQT PROD CO 0.00 0 0.00 0 0.00 0
2011 EQT PROD CO 0.00 0 0.00 0 0.00 0
2012 EQT PROD CO 802,990.00 256 0.00 0 0.00 0
2013 EQT PROD CO 449,871.00 365 0.00 0 0.00 0
2014 EQT PROD CO 502,268.00 365 0.00 0 0.00 0
2015 EQT PROD CO 321,688.00 237 0.00 0 0.00 0
2016 EQT PROD CO 135,402.00 163 0.00 0 0.00 0
2017 EQT PROD CO 54,749.00 41 0.00 0 0.00 0
2018 EQT PROD CO 413,680.00 312 0.00 0 0.00 0
2019 EQT PROD CO 426,031.00 356 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 EQT PROD CO Produced Fluid 16,638.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EQT PROD CO Produced Fluid 16,348.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EQT PROD CO Produced Fluid 4,126.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012 EQT PROD CO Fracing Fluid Waste 2,194.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EQT PROD CO Produced Fluid 101.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2012 EQT PROD CO Produced Fluid 1,027.00 Bbl INJECTION DISPOSAL WELL 34-007-24355
2012 EQT PROD CO Fracing Fluid Waste 452.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EQT PROD CO Fracing Fluid Waste 53.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 EQT PROD CO Produced Fluid 1,452.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EQT PROD CO Produced Fluid 199.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2013 EQT PROD CO Produced Fluid 2,365.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 EQT PROD CO Produced Fluid 1,577.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 EQT PROD CO Produced Fluid 1,802.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 EQT PROD CO Produced Fluid 109.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2013 EQT PROD CO Produced Fluid 347.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2013 EQT PROD CO Produced Fluid 985.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2014 EQT PROD CO Fracturing Fluid Waste 0.72 Tons LANDFILL 101397
2014 EQT PROD CO Produced Fluid 26.00 Bbl INJECTION DISPOSAL WELL 34-155-23196
2014 EQT PROD CO Produced Fluid 1,080.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Produced Fluid 3,981.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 EQT PROD CO Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL 34-007-2-3097
2015 EQT PROD CO Produced Fluid 236.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 EQT PROD CO Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL 34-155-23196
2015 EQT PROD CO Produced Fluid 203.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2015 EQT PROD CO Produced Fluid 1,708.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 450.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 EQT PROD CO Fracturing Fluid Waste 130.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2016 EQT PROD CO Produced Fluid 1,371.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2016 EQT PROD CO Produced Fluid 66.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 EQT PROD CO Produced Fluid 826.95 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 EQT PROD CO Produced Fluid 3,858.49 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 EQT PROD CO Drilling Fluid Waste 280.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 EQT PROD CO Produced Fluid 2,007.89 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 EQT PROD CO Other Oil & Gas Wastes 36.67 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 201.30 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 617.62 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 18.26 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 EQT PROD CO Produced Fluid 25.16 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 EQT PROD CO Other Oil & Gas Wastes 43.63 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 EQT PROD CO Other Oil & Gas Wastes 1.82 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 EQT PROD CO Produced Fluid 747.80 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 EQT PROD CO Produced Fluid 20.09 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 EQT PROD CO Other Oil & Gas Wastes 76.55 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 EQT PROD CO Produced Fluid 205.98 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 EQT PROD CO Produced Fluid 80.04 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 EQT PROD CO Other Oil & Gas Wastes 163.02 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 EQT PROD CO Other Oil & Gas Wastes 12.24 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 EQT PROD CO Produced Fluid 1,819.90 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 EQT PROD CO Produced Fluid 249.80 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 EQT PROD CO Produced Fluid 61.97 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 162.20 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 EQT PROD CO Produced Fluid 249.22 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 43.14 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Other Oil & Gas Wastes 15.82 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1990049 Primary Facility 2011-07-25 Drilling/Alteration No Violations Noted
2007090 Primary Facility 2011-09-29 Routine/Complete Inspection No Violations Noted
2015170 Primary Facility 2011-10-28 Routine/Complete Inspection Violation(s) Noted
2016563 Primary Facility 2011-10-28 Routine/Complete Inspection No Violations Noted
2031465 Primary Facility 2011-12-20 Follow-up Inspection No Violations Noted
2035438 Primary Facility 2012-01-10 Compliance Evaluation No Violations Noted
2040556 Primary Facility 2012-02-01 Routine/Complete Inspection No Violations Noted
2049645 Primary Facility 2012-03-02 Compliance Evaluation No Violations Noted
2065698 Primary Facility 2012-05-01 Compliance Evaluation No Violations Noted
2092639 Primary Facility 2012-08-10 Routine/Complete Inspection No Violations Noted Inspected wellhead only. Purpose of inspection was not to address any open violations on pad.
2150436 Primary Facility 2013-03-13 Routine/Complete Inspection No Violations Noted
2182501 Primary Facility 2013-07-09 Follow-up Inspection No Violations Noted
2230338 Primary Facility 2013-11-05 Routine/Complete Inspection No Violations Noted
2254907 Primary Facility 2014-02-27 Follow-up Inspection No Violations Noted
2257906 Primary Facility 2014-03-26 Routine/Partial Inspection No Violations Noted
2384357 Primary Facility 2015-06-26 Follow-up Inspection No Violations Noted Follow up inspection for 2012 violations. Operator nearing end of Act 2 process. Soil confirmation sampling scheduled for 7/1/15. TLT
2399594 Primary Facility 2015-08-17 Preoperation Inspection No Violations Noted ESCGP was amended. Inspection to document earth work completed following amendment and prior to drilling of new wells. Disturbed areas have been stabilized and E&S controls are installed. TLT
2485960 Primary Facility 2016-05-12 Routine/Partial Inspection No Violations Noted Inspection to resolve outstanding violations against the Phoenix 590627 well. DEP Environmental Cleanup and Brownfield Program has approved the Act 2 final report for attainment of the Statewide Health Standards for soil at the site. As such, the 2/1/12 and 8/2/12 violations against permit #117-20725 (Phoenix 590627) are resolved. No new issues were observed at the site. TLT
2531672 Primary Facility 2016-10-26 Routine/Complete Inspection No Violations Noted Inspection of EQT’s Phoenix 590796 (117-20970) unconventional gas well in Duncan Twp. Tioga County conducted October 26, 2016 at 11:50 am. At the time of inspection; the well had a production tree in place, shut-in. Analog pressure gauge on the tree top was shut-in from well, 0 PSI. There was a digital scada gauge on the production casing wing valve down in the cellar; not visible. The valve for the backside of the production casing (9 5/8” x 5 ½”) annulus was partially buried at the bottom of the cellar. The valve was open at the wellhead but shut in at the vent pipe plumped to surface. The operator has plans to plug this well. There are (6) other active wells on the pad in production; #590794 (117-20969), #590792 (117-20980), #590791 (117-20967), #590790 (117-20965), #590627 (117-20725), and #590025 (117-20994). Visual inspection of WH and cellars; no obvious concerns. Went over plugging procedure for the -796 with the operator. Expected to rig up on the well next week for plugging ops.
2533182 Primary Facility 2016-11-01 Routine/Complete Inspection No Violations Noted Inspection of EQT’s Phoenix 590796 (117-20970) unconventional gas well in Duncan Twp. Tioga County conducted November 1, 2016 at 10:00 am. At the time of inspection; a workover rig was rigged up on the well for plugging ops. I met with the Companymen to discuss operation on the pad. Wireline was rigged up for gauge run down to the obstruction (6470’). If run is successful they’ll set the CIBP in the 5 ½” prod. csg. @ 6450’, cap with cement using dump bailer. Tomorrow they’ll circulate gel, set second CIBP (4070’), run freepoint tool and shoot off casing above freepoint (pull ~3626’ 5 ½” production casing). Allied is lined up to mix, pump, and spot (3) balanced cement plugs; #1) from the production casing stub (~3626-2526) in the 8 ½” open hole, #2) in the open hole, across the 9 5/8” shoe up into the 9 5/8” (2576-2126), and #3) (1275-1225, in the 9 5/8” csg). I plan to return Thursday when they estimate spotting balanced plugs and asked the Companymen to catch a slurry sample if I’m not on location. Aside fr
2534407 Primary Facility 2016-11-03 Routine/Complete Inspection No Violations Noted Inspection of EQT’s Phoenix 590796 (117-20970) unconventional gas well in Duncan Twp. Tioga County conducted November 3, 2016 at 8 am. At the time of inspection; a workover rig was rigged up on the well for plugging ops. I met with the Companymen to discuss operation on the pad since my last visit Tuesday. CIBP has been set, 6450’ with 15’ cement dump bailed; sample displayed good strength. The wireline perf’d the 4 ½” at 3850’ so the rig can establish circulation to flush mud out of the annulus to avoid the well U-tubing when they go to pull casing (heavy drilling mud on the backside of csg), and ensure casing is free. The rig couldn’t establish circulation here; went uphole w/ perfs (3650’, 3450’, 3250’) and broke circulation at 3052’.. Plans going forward; shoot & pull production casing, cement w/ Allied as scheduled for remaining balanced cmt plugs. Aside from the well being plugged there are (6) active wells on the pad in production; #590794 (117-20969), #590792 (117-20980), #590791 (117-20967), #590790
2545938 Primary Facility 2016-12-13 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection of EQT’s Phoenix 590796 (117-20970) unconventional gas well in Duncan Twp. Tioga County conducted 12/13/16 at 11 am. WO Rig on location for remediation after bubbling inside the 9 5/8” was noticed after plugging ops. I met with the Companyman to discuss operations since my last visit 11/30. The rig drilled out (2) cmt plugs til they found good cmt @ ~2219. They set (2) CIBPs above that point, dump bailed 5’ cmt on top, some bubbling still reported at that point. They ran a downhole camera for which I reviewed the video on location; bubbling was definitely coming from below the bridge plugs, csg collars looked OK. At that point they circulated the hole and reportedly had no bubbling since. They set (2) more balanced cement plugs in the 9 5/8” as a precaution. The last blend they ran was 10% salt w 2% calcium chloride; samples showed good strength. No integrity issues reported on the 9 5/8”s annulus. Aside from the well being plugged there are (6) active wells on the pad in production; #590794 (117-
2551750 Primary Facility 2017-01-09 Routine/Partial Inspection No Violations Noted Routine partial inspection. Site snow covered. Well pad being prepared for arrival of the drill rig. Five new wells permitted and were reported as spud on 12/27/16. Entire pad surface covered by mats, which were underlain with textured liner. Crew on site working to berm up the liner around the perimeter of the pad. Impoundment 2 was frozen over and snow covered; adequate freeboard remained. Multiple piles of spoil material observed at staging area along access road. Material to be placed for subbase for the above ground storage tank pad, which will be constructed at the former Impoundment 1 location. TLT
2592176 Primary Facility 2017-05-10 Routine/Complete Inspection No Violations Noted I arrived on-site @11:20 hrs and met Bill Wallace of SWN. Patterson/UTI rig 294 on site, running pipe into the 593939 well, and anticipate skidding the rig to the 593940 well tonight. Site was neat, secondary containment was present and in good condition on top of rig mats. Chemical storage and backyard looked good. I departed the site @11:50 hrs.
2613966 Primary Facility 2017-07-06 Routine/Partial Inspection No Violations Noted No activity on the pad when I arrived. 10 K bbl. tank had been erected on the site, approximately 1/2 full of what appeared to be precipitation. Some water had collected in the pad containment near the edges; conductivity of this water was in the .45- .67 mS/cm range. The tank also appeared to have a remote monitoring system hooked up to it. Rig mats were still down over the entire pad from drilling operations. The liner berm at the site entrance seemed somewhat worn; I recommend that it be fully assessed before any fracing operations begin.
2657489 Primary Facility 2017-11-01 Incident- Response to Accident or Event No Violations Noted I met with Corey Giles of EQT and Neil Ketchum of Groundwater Sciences when I arrived. My inspection was in response to a reported release to the drainage ditch on the south side of the pad. A third party EHS group discovered water with elevated conductance (1-3.5 mS/cm) in the ditch on 10/31. The area had been more or less continuously vacced between the time it was discovered and the time I arrived. Corey and Neil had just finished taking soil and water conductance readings along the length of the ditch (see attached photos). Their investigation showed a gradient, beginning on the south side of the pad in the ditch approximately 100-125' east of the pad entrance, with the highest soil and water conductance in that area (6.77 mS/cm water, 2.57 mS/cm soil) and declining readings as they probed downgradient. At the time, the source of the water was unknown, but the area where the water was coming into the ditch seemed to be at the area of highest conductance. The containment berm on the pad had not yet
2743450 Primary Facility 2018-06-19 Routine/Complete Inspection No Violations Noted The DEP inspected the EQT – Phoenix Site C Well Pad located in Duncan Twp, Tioga Co. on 6/20/2018 @1100 hours. The weather was 78 degrees, 45% humidity and winds N 12mph. The receiving waters are listed as Sand Run (CWF) wild trout stream. The well site is in production. No activity was observed onsite during this inspection.

The site consists of the access road, freshwater impoundment, and well pad on a total of 22.4 acres. The impoundment is drawn down and almost empty. There are 11 wells currently in production, and one plugged well. The area surrounding the well pad appeared stabilized. A plastic bag containing old foam berms has blown onto the south slope of the pad and should be removed.

No new violations were noted during this inspection.

The following violations from Inspection Record #2657056 dated 11/01/2017, resulting from the release of a pollutional substance to the drainage ditch, remain OUTSTANDING against the PHOENIX 590627 Well (API#117-20725):

35 PS § 691.402(b) Potential to pollute

2801204 Primary Facility 2018-11-07 Routine/Complete Inspection No Violations Noted The DEP conducted a Routine inspection of the EQT - Phoenix Pad C located in Duncan Twp, Tioga Co. on 11/6/2018 @1115 hours. The weather was 52 degrees, rain, winds NNE13mph. No company personnel was present onsite during this inspection.

The site consists of the access road, freshwater impoundment, and well pad on a total of 22.4 acres. The impoundment is drawn down and almost empty. There are 11 wells currently capable of production, and one plugged well. The area surrounding the well pad appeared stabilized.


The following violations from Inspection Record #2657056 dated 11/01/2017, resulting from the release of a pollutional substance to the drainage ditch, remain OUTSTANDING against the PHOENIX 590627 Well (API#117-20725):

35 PS § 691.402(b) Potential to pollute waters of the Commonwealth 25 Pa Code 78a.57(a) Control, Storage and Disposal of Production Fluids 35 PS § 6018.301 SWMA Solid Waste Management Act

The following violations from Inspection Record #2674148 dated 12/20/2017, resulting from the

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2015170 623504 10/28/2011 2011-10-28 78.65(1)* - Rat hole not filled Environmental Health & Safety

For data sources see[8]

References