X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-20985

Well Details

Well ID: 37-117-20985
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Duncan Township
Operator Name: EQT PROD CO
Well Pad ID: 149048
Farm/Lease Name: PHOENIX 590892
License Status: INACTIVE
Spud Date:
Permit Date: 2010-11-05
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.649944
Longitude: -77.265150

For data sources see[1][2][3]

Well History

Date Event
2010-11-05 New Permit Application
2011-10-04 Performed Spud Operation
2011-11-04 Permit Renewal Application
2012-05-04 New Permit Application
2013-08-27 New Permit Application
2014-07-29 Permit Renewal Application
2014-10-17 Drilling Completion
2014-12-24 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-12-04 2014-12-12 7,620 7,523,960 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand (Proppant) FTS International Proppant Silica Substrate 14808-60-7 100 10.3048 7,235,450.0
Water FTS International Carrier/Base Fluid Water 7732-18-5 100 89.4225 62,787,500.0
ICI-3240 FTS International Biocide Dazomet 533-74-4 24 0.00253454 1779.61
Sodium hydroxide 1310-73-2 4 0.000422423 296.601
FE-100L FTS International Iron control Citric acid 77-92-9 55 0.000509083 357.45
APB-1 FTS International Breaker Ammonium persulfate 7727-54-0 95 0.00006359 44.65
CS-500-SI FTS International Scale inhibitor Ethylene glycol 107-21-1 10 0.00248761 1746.66
FRW-900 FTS International Friction reducer Alkyl alcohol Proprietary 10 0.00751542 5276.91
Hydrotreated light distillate 64742-47-8 30 0.0225463 15830.7
Oxyalkylated alcohol A Proprietary 5 0.00375771 2638.45
HVG-1 FTS International Gelling agent Surfactant 68439-51-0 2 0.00007768 54.543
Clay 14808-60-7 2 0.00007768 54.543
Petroleum distillate 64742-47-8 55 0.00213622 1499.93
Guar gum 9000-30-0 50 0.00194201 1363.57
Chlorine Dioxide Solution - SVP-Pure Neptune Disinfectant and/or oxidizer Chlorine dioxide 10049-04-4 0.3 0.00001222 8.578
CI-150 FTS International Acid corrosion inhibitor Ethylene glycol 107-21-1 30 0.00008472 59.483
Isopropanol 67-63-0 30 0.00008472 59.483
Quaternary ammonium compound Proprietary 10 0.00002824 19.828
Aromatic aldehyde Proprietary 10 0.00002824 19.828
Organic amine resin salt Proprietary 30 0.00008472 59.483
Dimethylformamide 68-12-2 10 0.00002824 19.828
Hydrochloric Acid (15%) FTS International Acidizing Hydrochloric Acid 7647-01-0 15 0.0228906 16072.5
NE-100 FTS International Non-emulsifier Dodecylbenzenesulfonic acid 27176-87-0 5 0.00001177 8.262
2-Butoxyethanol 111-76-2 10 0.00002353 16.523
2-Propanol 67-63-0 10 0.00002353 16.523

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 EQT PROD CO 0.00 0 0.00 0 0.00 0
2011 EQT PROD CO 0.00 0 0.00 0 0.00 0
2012 EQT PROD CO 0.00 0 0.00 0 0.00 0
2013 EQT PROD CO 0.00 0 0.00 0 0.00 0
2014 EQT PROD CO 0.00 0 0.00 0 0.00 0
2015 EQT PROD CO 739,525.00 267 0.00 0 0.00 0
2016 EQT PROD CO 624,989.00 364 0.00 0 0.00 0
2017 EQT PROD CO 577,861.00 364 0.00 0 0.00 0
2018 EQT PROD CO 712,431.00 360 0.00 0 0.00 0
2019 EQT PROD CO 553,221.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 EQT PROD CO Produced Fluid 1,100.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EQT PROD CO Fracing Fluid Waste 2,350.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Drilling Fluid Waste 115.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Drill Cuttings 785.00 Tons LANDFILL 301358
2015 EQT PROD CO Fracturing Fluid Waste 121.00 Tons LANDFILL 301358
2015 EQT PROD CO Produced Fluid 146.00 Bbl INJECTION DISPOSAL WELL 34-007-2-3097
2015 EQT PROD CO Fracing Fluid Waste 28,823.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL 34-007-23262
2015 EQT PROD CO Produced Fluid 200.00 Bbl INJECTION DISPOSAL WELL 34-059-24202
2015 EQT PROD CO Produced Fluid 4,365.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015 EQT PROD CO Produced Fluid 200.00 Bbl INJECTION DISPOSAL WELL 34-133-20525
2015 EQT PROD CO Fracing Fluid Waste 17,752.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 EQT PROD CO Produced Fluid 300.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2015 EQT PROD CO Produced Fluid 5,437.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 EQT PROD CO Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL 34-155-24076
2015 EQT PROD CO Produced Fluid 925.00 Bbl INJECTION DISPOSAL WELL 34-007-24355
2015 EQT PROD CO Produced Fluid 1,434.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2015 EQT PROD CO Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL 34-157-25511
2015 EQT PROD CO Produced Fluid 300.00 Bbl INJECTION DISPOSAL WELL 34-155-23196
2015 EQT PROD CO Produced Fluid 34,155.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 2,478.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 4,608.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 EQT PROD CO Produced Fluid 5,069.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017 EQT PROD CO Produced Fluid 4,133.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 EQT PROD CO Other Oil & Gas Wastes 564.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 795.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 375.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2017 EQT PROD CO Other Oil & Gas Wastes 104.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 EQT PROD CO Produced Fluid 274.20 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 EQT PROD CO Produced Fluid 19.01 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 EQT PROD CO Produced Fluid 395.73 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Produced Fluid 2,150.81 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 EQT PROD CO Other Oil & Gas Wastes 41.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 EQT PROD CO Other Oil & Gas Wastes 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 EQT PROD CO Other Oil & Gas Wastes 142.85 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 EQT PROD CO Produced Fluid 184.55 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 EQT PROD CO Produced Fluid 250.62 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 EQT PROD CO Other Oil & Gas Wastes 155.00 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 92.85 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Produced Fluid 184.09 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 1,222.92 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 EQT PROD CO Other Oil & Gas Wastes 173.27 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 EQT PROD CO Other Oil & Gas Wastes 127.15 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 150.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 EQT PROD CO Other Oil & Gas Wastes 2.86 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 EQT PROD CO Other Oil & Gas Wastes 92.85 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 EQT PROD CO Other Oil & Gas Wastes 649.43 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 EQT PROD CO Produced Fluid 116.08 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 EQT PROD CO Produced Fluid 7.72 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 57.18 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 498.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 EQT PROD CO Produced Fluid 2,476.04 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1974961 Primary Facility 2011-05-13 Routine/Complete Inspection No Violations Noted RTNC insp. E&S viols against 883 insp (#1974299). TLT
2001185 Primary Facility 2011-08-30 Routine/Complete Inspection No Violations Noted
2066469 Primary Facility 2012-05-09 Routine/Complete Inspection No Violations Noted
2126736 Primary Facility 2012-12-28 Routine/Partial Inspection No Violations Noted
2139765 Primary Facility 2013-02-06 Routine/Partial Inspection No Violations Noted
2145026 Primary Facility 2013-03-01 Routine/Partial Inspection No Violations Noted
2230378 Primary Facility 2013-11-05 Routine/Complete Inspection No Violations Noted
2254690 Primary Facility 2014-02-27 Follow-up Inspection No Violations Noted
2313439 Primary Facility 2014-10-03 Drilling/Alteration No Violations Noted
2319522 Primary Facility 2014-11-06 Routine/Complete Inspection No Violations Noted
2328170 Primary Facility 2014-11-25 Routine/Partial Inspection No Violations Noted Drill rig recently moved off site. Site preparation and mobilization for frac ongoing during inspection. TLT
2336085 Primary Facility 2015-01-13 Administrative/File Review No Violations Noted Review of lab results for samples collected on 11/25/14 from standing water on pad surface following drilling operations. Results show concentrations that exceed Department standards for constituents indicative of oil and gas operations. Violations cited against Phoenix 590888 well permit (117-20981) TLT.
2343276 Primary Facility 2015-02-11 Routine/Complete Inspection No Violations Noted
2352481 Primary Facility 2015-03-11 Routine/Partial Inspection No Violations Noted Violation cited against Phoenix 590888 well (117-20981) during 3/11/15 inspection for failure to maintain E&S controls to prevent the potential for accelerated erosion and sedimentation. Access road to the site not maintained to prevent tracking of mud onto State Route 3009. Equipment mobilized to site the next day to sweep SR 3009 and improve stabilization on the access road. Violation immediately corrected. TLT
2367831 Primary Facility 2015-05-04 Follow-up Inspection No Violations Noted Follow up inspection to resolve 1/13/15 violations. New violations observed and cited against Phoenix 590888 well (117-20981). TLT
2375729 Primary Facility 2015-05-29 Follow-up Inspection No Violations Noted Follow up inspection to verify whether 5/4/15 violations (cited against 117-20981) have been resolved. Stained material still present. Sample 2519-626 collected. TLT
2407353 Primary Facility 2015-09-14 Follow-up Inspection No Violations Noted Follow up inspection to resolve the 5/4/15 violations against the Phoenix 590888 well (117-20981). EQT provided a follow up response on 6/8/15 that included soil sample results to document the cleanup. Concentrations were below applicable standards. 5/29/15 Department results were also below the applicable standards. TLT
2511850 Primary Facility 2016-08-16 Routine/Partial Inspection No Violations Noted Partial inspection to observe reclamation of Impoundment #1. Impoundment dewatered and liner removed. Gray subbase material observed on impoundment walls and floor. Field conductivity screening completed of standing water and impoundment floor soil. No violations cited. TLT
2530388 Primary Facility 2016-10-14 Routine/Complete Inspection No Violations Noted Routine inspection. Both freshwater impoundments and topsoil stockpile have been reclaimed. The east and south well pad corner sumps have been removed and an infiltration basin constructed southeast of the well pad. No violations cited. TLT
2531654 Primary Facility 2016-10-26 Routine/Complete Inspection No Violations Noted Inspection of EQT’s Phoenix 590997 (117-20977) plugged well in Duncan Twp. Tioga Co. conducted October 26, 2016 at 12:15 pm. At the time of inspection; the cellar was filled with water with 3” tagged standpipe monument about 8’ high. The top of the monument was open ended “T”, ran hose for Altair 5x gas meter in the vent; no gas detected. There were (7) active gas wells in production on the pad; #590885 (117-20966), #590884 (117-20975), #590883 (117-20974), #590892 (117-20985), #590890 (117-20983), #590889 (117-20982), #590888 (117-20981). Conducted visual inspection of WH and cellar; no obvious conecrns.
2535690 Primary Facility 2016-11-03 Site Restoration No Violations Noted Well Site Restoration Reports (WSRRs) received on 11/1/16. Since the new 25 Pa Code Ch. 78a regulations are in effect, WSRR's are to be submitted on the updated form through the Greenport website. This information was conveyed to EQT along with the request that the WSRRs be submitted electronically on the updated form. Interim restoration has been completed at the site and vegetative cover is becoming established. TLT
2544176 Primary Facility 2016-12-06 Site Restoration No Violations Noted Restoration inspection. Notice of Termination (NOT) received on 11/16/16 and Well Site Restoration Report submitted through Greenport on 12/6/16. Post-construction stormwater management BMPs have been installed. Vegetation is becoming established, however, entire site has not achieved 70% uniform vegetative cover and silt sock remains in place at the former Impoundment #1 location. Recommend that NOT be denied. Recommend that the NOT and WSRR be resubmitted after vegetation becomes more established and silt sock is removed. TLT
2551742 Primary Facility 2017-01-12 Routine/Complete Inspection No Violations Noted
2596541 Primary Facility 2017-05-19 Site Restoration No Violations Noted On 5/19/17 at 1402 hrs I conducted an inspection of the Phoenix Pad R well site. No one was present during the inspection. It was mostly sunny and 84°F.

I observed the site and reviewed the erosion and sedimentation (E&S) routine inspection log, the Notice of Termination (NOT) and the Well Site Restoration Report (WSRR).

The well site has been restored and post-construction stormwater management (PCSM) BMPs have been installed. Temporary E&S controls have been removed and the project is permanently stabilized as per 25 Pa Code Section 102.22(a)(2). The last routine E&S inspection was conducted on 5/15/17.

Based on existing conditions, I recommend approval of the NOT. The WSRR was approved on 5/22/17. No violations were cited during this inspection. I concluded the inspection at 1433 hrs. TLT

2678337 Primary Facility 2018-01-04 Routine/Complete Inspection No Violations Noted The Department of Environmental Protection (DEP) inspected the EQT Phoenix pad R located in Duncan Township, Tioga County on January 4, 2018 at 1130 hrs. The weather was 16 degrees. Overcast with 3 inches of snow on the ground. 22 mph winds out of the NW. Humidity 61%. Pressure 29.7 inHg.

No activity was observed on site during the inspection. There appear to be seven active wells on the pad 590883-590885, 590888-590890, 590892. An AST labeled "freshwater only" was observed onsite. Containment with matting was observed under the hoses. A number of water trucks were idling onsite.

No issues were observed. No violations were noted at this time. I departed the site at 1330 hours.

2702195 Primary Facility 2018-03-06 Routine/Partial Inspection No Violations Noted The department of environmental protection conducted an inspection of the EQT Phoenix pad R in response to report of a spill to the ground surface received March 3, 2018 @1315 hours. Present onsite was Jim Kelley, EQT Assistant Superintendent.

A stuck dump valve caused an overfill of a 100 BBL capacity storage tank. EQT estimated the spill of produced water to be between 30-40 gallons. The fluid settled in a low area on the pad surface adjacent to the tank. The impacted area, approximately 15' x 5' x 10", was excavated and "burrito" wrapped in plastic until a waste rolloff container was delivered.

As of today's inspection, the impacted material has been moved to the rolloff container. The excavated area has been backfilled with clean gravel. Mr. Kelley reported the malfunctioning valve has been repaired. A copy of the monthly tank inspection report, required under 25 Pa Code 78a.57(i), was requested from the Operator.

I departed the site at 1400 hours.

2807970 Primary Facility 2018-11-28 Routine/Partial Inspection No Violations Noted The DEP conducted an INCIDENT inspection of the EQT Pad R site located in Duncan Twp, Tioga Co. on 10/28/2018 at 1015 hours in response to spill notification #338402.

Cory Guiles of EQT reported that at 2:40 pm on 11/27/2018, "there was a release of hydraulic fluid to the pad surface. There was a mechanical failure on a water truck that allowed 20 gallons of hydraulic fluid to be released to the pad surface of Phoenix R. They are in the process of cleaning up the impacted soil now and will store it in drums."

As of today's inspection, no personnel were located onsite. I contacted Corey Giles, EQT to confirm the location of the spill. He stated he was under the impression it was in front of the production tanks, approximately 1 barrel of material was removed and had already been backfilled with clean material. During the course of the inspection Tim Ryan, EQT well tender appeared onsite and showed me the location of the spill. A small area adjacent to the well heads appears to have been recently disturbed.

For data sources see[8]