X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-21783

Well Details

Well ID: 37-117-21783
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Duncan Township
Operator Name: EQT PROD CO
Well Pad ID: 149047
Farm/Lease Name: PHOENIX 593941
License Status:
Spud Date: 2016-12-27
Permit Date: 2015-07-24
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.645392
Longitude: -77.290586

For data sources see[1][2][3]

Well History

Date Event
Deviated
2015-07-24 New Permit Application
2016-07-19 Permit Renewal Application
2016-12-27 Performed Spud Operation
2017-05-10 MOD
2017-06-28 Drilling Completion

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2017-07-30 2017-08-20 7,784 13,248,900 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Other Chemical(s) Listed Above See Trade Name(s) List Listed Below
CI-150 FTS International Acid Corrosion Inhibitor Listed Below
CS-500-SI FTS International Scale Inhibitor Listed Below
MX-8-2544 Multi-Chem Bacteria Treatment Listed Below
MX-5-3886 Multi-Chem Bacteria Treatment Listed Below
HVG-1 FTS International Gelling Agent Listed Below
Hydrochloric Acid (15%) FTS International Acidizing Listed Below
Sand (Proppant) FTS International Proppant Listed Below
APB-1 FTS International Gelling Agent Listed Below
Water FTS International Carrier/Base Fluid Water 7732-18-5 100 87.8073 110,562,000.0
Ethylene Glycol 107-21-1 30 0.00008267 104.096
Hydrochloric Acid 7647-01-0 15 0.022338 28126.8
Sodium Nitrate 7631-99-4 5 0.000475973 599.318
Petroleum Distillate 64742-47-8 55 0.000901259 1134.82
Alcohols, C11-14-iso-, C13-rich, ethoxylated 78330-21-9 5 0.00372241 4687.05
Sodium Chloride 7647-14-5 100 0.00951945 11986.4
Guar Gum 9000-30-0 50 0.000819326 1031.65
Sodium Chloride 7647-14-5 100 0.00951945 11986.4
Clay 14808-60-7 2 0.00003277 41.266
Surfactant 68439-51-0 2 0.00003277 41.266
Clay 14808-60-7 2 0.00003277 41.266
Petroleum Distillate 64742-47-8 55 0.000901259 1134.82
Alcohols, C11-14-iso-, C13-rich, ethoxylated 78330-21-9 5 0.00372241 4687.05
Isopropanol 67-63-0 30 0.00008267 104.096
Distillates (Petroleum), Hydrotreated Light 64742-47-8 30 0.0223345 28122.3
Calcium Nitrate.4H2O 13477-34-4 100 0.10682 134502
Polyactide Resin 9051-89-2 98 0.0656381 82647.9
Ammonium Persulfate 7727-54-0 95 0.000473721 596.484
Organic Amine Resin Salt Proprietary 30 0.00008267 104.096
Guar Gum 9000-30-0 50 0.000819326 1031.65
Silica Substrate 14808-60-7 100 11.7596 14,807,100.0
Polyactide Resin 9051-89-2 98 0.0656381 82647.9
Sodium Nitrate 7631-99-4 5 0.000475973 599.318
Surfactant 68439-51-0 2 0.00003277 41.266
Aromatic Aldehyde Proprietary 10 0.00002756 34.699
Quaternary Ammonium Compound Proprietary 10 0.00002756 34.699
Ethylene Glycol 107-21-1 10 0.00239779 3019.17
Calcium Nitrate.4H2O 13477-34-4 100 0.10682 134502
Distillates (Petroleum), Hydrotreated Light 64742-47-8 30 0.0223345 28122.3
Dimethylformamide 68-12-2 10 0.00002756 34.699
FRW-1450 FTS International Friction Reducer Listed Below
Nu Flow 1000 FTS International Diverting Agent Listed Below

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2016 EQT PROD CO 0.00 0 0.00 0 0.00 0
2017 EQT PROD CO 381,076.00 85 0.00 0 0.00 0
2018 EQT PROD CO 2,065,517.00 365 0.00 0 0.00 0
2019 EQT PROD CO 1,253,851.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2017 EQT PROD CO Other Oil & Gas Wastes 295.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 EQT PROD CO Soil Contaminated by Oil & Gas Related Spills 2.19 Tons LANDFILL 301358
2017 EQT PROD CO Produced Fluid 950.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 EQT PROD CO Other Oil & Gas Wastes 220.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Soil Contaminated by Oil 2.19 Tons LANDFILL 301358
2017 EQT PROD CO Synthetic Liner Materials 18.91 Tons LANDFILL 301358
2017 EQT PROD CO Produced Fluid 214.10 Tons LANDFILL 301358
2017 EQT PROD CO Produced Fluid 2,203.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 EQT PROD CO Drilling Fluid Waste 800.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 EQT PROD CO Produced Fluid 1,780.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Other Oil & Gas Wastes 150.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 EQT PROD CO Drill Cuttings 1,481.25 Tons LANDFILL 301358
2017 EQT PROD CO Drilling Fluid Waste 2,959.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 EQT PROD CO Other Oil & Gas Wastes 10,013.47 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 EQT PROD CO Produced Fluid 5,459.22 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 EQT PROD CO Waste Water Treatment Sludge 91.34 Tons RESIDUAL WASTE PROCESSING FACILITY ORDER 2016-29
2018 EQT PROD CO Produced Fluid 84.60 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 EQT PROD CO Produced Fluid 3,478.76 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Synthetic Liner Materials 133.91 Tons LANDFILL 301358
2018 EQT PROD CO Produced Fluid 947.69 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 14,998.52 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 EQT PROD CO Other Oil & Gas Wastes 36.67 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 1.82 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 EQT PROD CO Other Oil & Gas Wastes 18.26 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 EQT PROD CO Other Oil & Gas Wastes 76.55 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 EQT PROD CO Produced Fluid 1,004.73 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 EQT PROD CO Produced Fluid 843.16 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 EQT PROD CO Other Oil & Gas Wastes 43.63 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 EQT PROD CO Produced Fluid 5,691.73 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 EQT PROD CO Produced Fluid 907.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 EQT PROD CO Produced Fluid 224.31 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 EQT PROD CO Other Oil & Gas Wastes 15.82 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 EQT PROD CO Produced Fluid 126.26 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Other Oil & Gas Wastes 12.24 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 EQT PROD CO Other Oil & Gas Wastes 2.17 Tons LANDFILL 301358
2019 EQT PROD CO Other Oil & Gas Wastes 163.02 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 EQT PROD CO Produced Fluid 188.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 471.15 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2399602 Primary Facility 2015-08-17 Preoperation Inspection No Violations Noted ESCGP was amended. Inspection to document earth work completed following amendment and prior to drilling of new wells. Disturbed areas have been stabilized and E&S controls are installed. TLT
2485969 Primary Facility 2016-05-12 Routine/Partial Inspection No Violations Noted Inspection to resolve outstanding violations against the Phoenix 590627 well. DEP Environmental Cleanup and Brownfield Program has approved the Act 2 final report for attainment of the Statewide Health Standards for soil at the site. As such, the 2/1/12 and 8/2/12 violations against permit #117-20725 (Phoenix 590627) are resolved. No new issues were observed at the site. TLT
2551774 Primary Facility 2017-01-09 Routine/Partial Inspection No Violations Noted Routine partial inspection. Site snow covered. Well pad being prepared for arrival of the drill rig. Five new wells permitted and were reported as spud on 12/27/16. Entire pad surface covered by mats, which were underlain with textured liner. Crew on site working to berm up the liner around the perimeter of the pad. Impoundment 2 was frozen over and snow covered; adequate freeboard remained. Multiple piles of spoil material observed at staging area along access road. Material to be placed for subbase for the above ground storage tank pad, which will be constructed at the former Impoundment 1 location. TLT
2592185 Primary Facility 2017-05-10 Routine/Complete Inspection No Violations Noted I arrived on-site @11:20 hrs and met Bill Wallace of SWN. Patterson/UTI rig 294 on site, running pipe into the 593939 well, and anticipate skidding the rig to the 593940 well tonight. Site was neat, secondary containment was present and in good condition on top of rig mats. Chemical storage and backyard looked good. I departed the site @11:50 hrs.
2614029 Primary Facility 2017-07-06 Routine/Partial Inspection No Violations Noted No activity on the pad when I arrived. 10 K bbl. tank had been erected on the site, approximately 1/2 full of what appeared to be precipitation. Some water had collected in the pad containment near the edges; conductivity of this water was in the .45- .67 mS/cm range. The tank also appeared to have a remote monitoring system hooked up to it. Rig mats were still down over the entire pad from drilling operations. The liner berm at the site entrance seemed somewhat worn; I recommend that it be fully assessed before any fracing operations begin.
2657512 Primary Facility 2017-11-01 Incident- Response to Accident or Event No Violations Noted I met with Corey Giles of EQT and Neil Ketchum of Groundwater Sciences when I arrived. My inspection was in response to a reported release to the drainage ditch on the south side of the pad. A third party EHS group discovered water with elevated conductance (1-3.5 mS/cm) in the ditch on 10/31. The area had been more or less continuously vacced between the time it was discovered and the time I arrived. Corey and Neil had just finished taking soil and water conductance readings along the length of the ditch (see attached photos). Their investigation showed a gradient, beginning on the south side of the pad in the ditch approximately 100-125' east of the pad entrance, with the highest soil and water conductance in that area (6.77 mS/cm water, 2.57 mS/cm soil) and declining readings as they probed downgradient. At the time, the source of the water was unknown, but the area where the water was coming into the ditch seemed to be at the area of highest conductance. The containment berm on the pad had not yet
2743506 Primary Facility 2018-06-19 Routine/Complete Inspection No Violations Noted The DEP inspected the EQT – Phoenix Site C Well Pad located in Duncan Twp, Tioga Co. on 6/20/2018 @1100 hours. The weather was 78 degrees, 45% humidity and winds N 12mph. The receiving waters are listed as Sand Run (CWF) wild trout stream. The well site is in production. No activity was observed onsite during this inspection.

The site consists of the access road, freshwater impoundment, and well pad on a total of 22.4 acres. The impoundment is drawn down and almost empty. There are 11 wells currently in production, and one plugged well. The area surrounding the well pad appeared stabilized. A plastic bag containing old foam berms has blown onto the south slope of the pad and should be removed.

No new violations were noted during this inspection.

The following violations from Inspection Record #2657056 dated 11/01/2017, resulting from the release of a pollutional substance to the drainage ditch, remain OUTSTANDING against the PHOENIX 590627 Well (API#117-20725):

35 PS § 691.402(b) Potential to pollute

For data sources see[8]

References