X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-121-46172

Well Details

Well ID: 37-121-46172
Loading map...
Country: United States
State: Pennsylvania
County: Venango
Municipality: Cranberry Township
Operator Name: PENNFIELD ENERGY LLC
Well Pad ID:
Farm/Lease Name: SPEERSTRA SOUTH 38
License Status:
Spud Date:
Permit Date: 2018-01-23
Well Type: OIL
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.350317
Longitude: -79.621642

For data sources see[1][2][3]

Well History

Date Event
2018-01-23 New Permit Application
2018-09-19 Performed Spud Operation

For data sources see[4]



Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2753445 Primary Facility 2018-07-16 Routine/Complete Inspection No Violations Noted Onsite for a routine inspection. The permit is posted onsite, site is constructed, and drilling has not commenced. Exposed soil should be temporarily stabilized.
2776656 Primary Facility 2018-09-18 Routine/Complete Inspection No Violations Noted Onsite for a routine inspection. Drilling has not commenced. Equipment is being moved onsite. Pit has been dug and is dry. The site is stable with no E&S issues.
2777186 Primary Facility 2018-09-20 Drilling/Alteration No Violations Noted Howard Drilling rig on location. No one on site at time of inspection. Drilling has commenced. Load of 7" on location. Tophole water discharged into an unlined pit.
2777792 Primary Facility 2018-09-20 Routine/Complete Inspection No Violations Noted Onsite for a routine inspection. The permit is posted onsite. Currently drilling the well utilizing an unlined pit. Fluid is being retained in the unlined pit. The site is stable. There are no E&S issues.
2779729 Primary Facility 2018-09-25 Drilling/Alteration No Violations Noted Inspection shows rig TD at 1236ft. Rig currently tripping out. Drill cuttings and fluids contained in an unlined pit (alt method approved). Attached records show 319ft of 9-5/8 cement with 104sks (7.5 bbl returns) and 589ft of 7inch cement with 55sks (2 bbl returns).
2780334 Primary Facility 2018-09-24 Routine/Complete Inspection No Violations Noted Onsite for a routine inspection. The drill rig is onsite, but currently not drilling. Pit is unlined and has greater than 2 feet of freeboard. The site is stable with no E&S issues.
2780357 Primary Facility 2018-09-26 Routine/Complete Inspection No Violations Noted Onsite for a routine inspection. The well is drilled utilizing an unlined pit. The site is stable with no E&S issues.
2781391 Primary Facility 2018-09-28 Drilling/Alteration No Violations Noted Well has been drilled. Equipment has been moved off of location. Well is equipped with swedge and is waiting to be stimmed.
2796221 Primary Facility 2018-10-29 Routine/Complete Inspection No Violations Noted Onsite for a routine inspection. No one is onsite, set up to stimulate well on 10/30/18. Pit is lined with greater than two feet of free board. The access road and well site are soft, but sediment is not leaving the site. There are no E&S issues.
2796226 Primary Facility 2018-10-30 Routine/Complete Inspection No Violations Noted Onsite for a routine inspection. Currently stimulating the well. Containment is setup and fluids are being properly handled. The site is soft but sediment is not leaving the site. There are no issues.
2797992 Primary Facility 2018-11-02 Routine/Complete Inspection No Violations Noted Onsite for a routine inspection. The well is producing, not labeled, and the annulus is vented. Pit has been enclosed and the site graded. Site should be temporally stabilized.
2817328 Primary Facility 2018-12-17 Administrative/File Review Violation(s) Noted A review of the Departments records revealed the operator did not submit a Well Record within 30 calendar days of cessation of drilling a well. Well record shows drilling completed on 9/25/18. Well Record received on 12/14/18. Records also revealed operator failed to submit a completion report within 30 calendar days after completion of the well. Completion Report shows well completion date 10/30/18. Completion Report received on 12/14/18.
2818995 Primary Facility 2018-12-20 Routine/Complete Inspection No Violations Noted Onsite for a routine inspection. The well is producing, labeled, and the annulus is vented. Site is stable and has been temporarily stabilized. There are areas of the access roads that are soft and rutted. Steps should be taken to stabilize the roads.
2840988 Primary Facility 2019-02-15 Routine/Complete Inspection No Violations Noted Onsite form routine inspection. The well is producing, labeled, and the annulus is plumbed to the tank. The site is frozen and snow covered. There are no E&S issues.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2817328 836787 2018-12-17 2018-12-20 78.122(A) Administrative
2817328 836788 2018-12-17 2018-12-20 OGA 3222(B3) Administrative

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
836787 371299 NOV - Notice of Violation 2018-12-20
836787 375242 CPA - Civil Penalty Assessment Comply/Closed 2020-01-31 $16,285.00 $0.00
836787 383502 CACP - Consent Assessment of Civil Penalty $10,000.00 $5,000.00
836788 371299 NOV - Notice of Violation 2018-12-20
836788 375242 CPA - Civil Penalty Assessment Comply/Closed 2020-01-31 $16,285.00 $0.00
836788 383502 CACP - Consent Assessment of Civil Penalty $10,000.00 $5,000.00

For data sources see[5]

References