{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.277539,"lon":-80.027283,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Washington | |
Municipality: Union Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 145422 | |
Farm/Lease Name: TRAX FARMS 592307 | |
License Status: | |
Spud Date: | |
Permit Date: 2013-11-08 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 40.277539 | |
Longitude: -80.027283 |
Date | Event |
---|---|
2013-11-08 | New Permit Application |
2013-11-14 | Performed Spud Operation |
2014-02-13 | New Permit Application |
2014-07-08 | Drilling Completion |
2015-03-13 | Perforation |
2015-03-13 | Performed Stimulation |
2016-06-23 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2015-03-13 | 2015-03-22 | 7,231 | 10,075,700 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Super TSC LT | Nabors Completion and Production Services | Scale control | Proprietary non-hazardous materials | Proprietary | 100 | 0.0272698 | 25510.7 |
Sand (Proppant) | Nabors Completion and Production Services | Proppant | Silica Substrate | 14808-60-7 | 100 | 9.69919 | 9,073,500.0 | |
MC MX 437-5 | Multi-Chem | Calcium nitrate solution | Calcium nitrate | 10124-37-5 | 60 | 0.0575143 | 53804.1 | |
LSG-100 | Nabors Completion and Production Services | Gelling agent | Solvent naphtha | 64742-47-8 | 65 | 0.00170567 | 1595.64 | |
Proprietary non-hazardous polymers | Proprietary | 60 | 0.00157447 | 1472.9 | ||||
Water | Nabors Completion and Production Services | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 89.8795 | 84,081,500.0 | |
AI-2 | Nabors Completion and Production Services | Acid Inhibitor | Propargyl Alcohol | 107-19-7 | 40 | 0.000160729 | 150.36 | |
Ethoxylated Nonylphenol | 68412-54-4 | 13 | 0.00005224 | 48.867 | ||||
Isopropyl Alcohol | 67-63-0 | 40 | 0.000160729 | 150.36 | ||||
Benzyl Chloride-Quaternized | 72480-70-7 | 10 | 0.00004018 | 37.59 | ||||
Glycol Ethers | 111-76-2 | 40 | 0.000160729 | 150.36 | ||||
Hydrochloric Acid (15%) | Nabors Completion and Production Services | Acidizing | Hydrochloric Acid | 7647-01-0 | 15 | 0.0325719 | 30470.7 | |
WFR-12W | Nabors Completion and Production Services | Friction reducer | Anionic water-soluble polymer | Proprietary | 100 | 0.0779397 | 72911.9 | |
OB-2 | Nabors Completion and Production Services | Gel Breaker | Ammonium Persulfate | 7727-54-0 | 100 | 0.00003068 | 28.7 | |
Sillica, crystalline quartz | 7631-86-9 | 30 | 0.00000920 | 8.61 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2015-03-13 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | EQT PROD CO | 1,159,775.00 | 234 | 0.00 | 0 | 0.00 | 0 |
2016 | EQT PROD CO | 2,429,248.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 1,728,329.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 1,041,775.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 838,024.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2014 | EQT PROD CO | Drill Cuttings | 123.00 Tons | LANDFILL | PAD059087072 |
2014 | EQT PROD CO | Fracing Fluid Waste | 425.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EQT PROD CO | Drill Cuttings | 359.00 Tons | RESIDUAL WASTE TRANSFER FACILITY | 301071 |
2015 | EQT PROD CO | Fracturing Fluid Waste | 25.00 Tons | LANDFILL | SWF 1032-WV0109 |
2015 | EQT PROD CO | Produced Fluid | 110.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2015 | EQT PROD CO | Produced Fluid | 8,020.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Produced Fluid | 1,980.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2015 | EQT PROD CO | Fracturing Fluid Waste | 26.00 Tons | LANDFILL | 100419 |
2015 | EQT PROD CO | Fracing Fluid Waste | 170.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Fracturing Fluid Waste | 21.00 Tons | LANDFILL | 101397 |
2016 | EQT PROD CO | Other Oil & Gas Wastes | 64.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid | 242.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016 | EQT PROD CO | Produced Fluid | 130.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016 | EQT PROD CO | Produced Fluid | 130.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW010 |
2016 | EQT PROD CO | Produced Fluid | 650.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2016 | EQT PROD CO | Produced Fluid | 9,425.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | EQT PROD CO | Produced Fluid | 185.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 670.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 130.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | EQT PROD CO | Produced Fluid | 2,352.00 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 142.11 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Produced Fluid | 256.76 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 139.47 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Produced Fluid | 31.16 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 27.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 9.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2019 | EQT PROD CO | Produced Fluid | 28.35 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 135.00 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 1,063.74 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 11.58 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2231142 | Primary Facility | 2013-12-02 | Drilling/Alteration | No Violations Noted | |
2284048 | Primary Facility | 2014-07-03 | Drilling/Alteration | No Violations Noted | Pioneer Rig 70 |
2285749 | Primary Facility | 2014-07-10 | Drilling/Alteration | No Violations Noted | Pioneer Rig 70 |
2291570 | Primary Facility | 2014-07-02 | Routine/Complete Inspection | No Violations Noted | Pioneer rig 70 engaged in drilling operations on-site at time of inspection. No leaks of fluids fluids noted. Slip area adjacent to northwest area of pad is matted. No other E&S issues noted. |
2293889 | Primary Facility | 2014-07-24 | Routine/Complete Inspection | No Violations Noted | Slip area adjacent to northwest area of pad has vegetative growth. No other E&S issues or dust noted. Department recommends operator ensure slip doesn't threaten to compromise integrity of the well pad. Department also recommends operator review reclamation plan and submit modification of ESCGP if necessary. |
2306014 | Primary Facility | 2014-06-20 | Routine/Partial Inspection | No Violations Noted | This inspection was conducted in response to a report of a chemical release and smoke billowing from the pad. Upon arrival at the pad it was noted that three diesel generators were operating on the pad. The diesels periodically released black smoke when they came under load during pipe stripping operations. Smoke did not appear to be excessive at the time of inspection. The site inspection was conducted concurrently with inspections for its associated wells. |
2306034 | Primary Facility | 2014-09-17 | Routine/Complete Inspection | No Violations Noted | Site ID sign was correct. ESCGP was on-site. AST was erected on pad. No E&S issues noted. Well labels need updated. The site inspection was conducted concurrently with inspections for its associated wells. Wells on this pad target the Marcellus or Geneseo layers. |
2349793 | Primary Facility | 2015-03-05 | Routine/Complete Inspection | No Violations Noted | |
2352588 | Primary Facility | 2015-03-17 | Drilling/Alteration | No Violations Noted | Nabors Completion and Production Services |
2354917 | Primary Facility | 2015-03-25 | Drilling/Alteration | No Violations Noted | Nabors Completion and Production Services |
2405503 | Primary Facility | 2015-08-27 | Routine/Complete Inspection | No Violations Noted | On 8/27/15, I performed an NOT inspection with WQS Bryon Miller on the Trax Farms site in response to an NOT request from the operator and made the following observations: |
2627151 | Primary Facility | 2017-08-18 | Routine/Complete Inspection | No Violations Noted | On 8/18/2017 an RTNC inspection of the Trax Farms well site was conducted in response to a prior discussion with operator personnel about the condition of the wet pond on the site. The following was observed:
>> The wet pond area was generally well vegetated at the time of inspection with a mixture of the required plant types as well as various other plants. Two large bare patches were noted. >>Chain link fence was installed around the wet pond area to prevent wildlife from grazing on plantings. >>Twelve wells were observed on site at the time of inspection. >>As with prior inspections a number of areas of sparse growth were noted on some of the very steep slopes around the site. |
2692908 | Primary Facility | 2018-02-09 | Site Restoration | No Violations Noted | On 2/9/18 a restoration inspection was conducted at the Trax Farms Pad A in response to an operator submitted request for permit termination. The site was found to be in good condition with no issues found to prevent termination. |
2756083 | Primary Facility | 2018-07-25 | Routine/Complete Inspection | No Violations Noted | This well has been completed and is producing. The well and site appear to be well maintained. |