X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-125-27878

Well Details

Well ID: 37-125-27878
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Carroll Township
Operator Name: EQT PROD CO
Well Pad ID: 148479
Farm/Lease Name: HAYWOOD 593807
License Status:
Spud Date:
Permit Date: 2016-02-10
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.178594
Longitude: -79.975919

For data sources see[1][2][3]

Well History

Date Event
2016-02-10 New Permit Application
2016-05-16 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2017-05-19 2017-06-02 7,717 13,304,700 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 MC MX 5-3886 Multi-Chem Specialty Brine Listed Below
KSI-19 Keane Scale Inhibitor Listed Below
Other Chemical(s) Listed Above See Trade Name(s) List water 7732-18-5 60 0.000406453 520.728
KFR-23 Keane Friction Reducer Water 7732-18-5 50 0.015128 19381.2
Sand (Proppant) FTS International Proppant Listed Below
Water Keane Carrier/Base Fluid Water 7732-18-5 100 86.6622 111,027,000.0
LD-2550 Multi-Chem Additive water 7732-18-5 60 0.000406453 520.728
LD-2250 Mult-Chem Friction Reducer Listed Below
Hydrochloric Acid (15%) FTS International Acidizing Listed Below
MC MX 8-2544 Multi-Chem Live Culture - Nitrate Reducing Bacteria Listed Below
KFR-Activator-1 Keane Activator Listed Below
KAI-12 Keane Acid Inhibitor Listed Below
2-ethylhexanol 104-76-7 5 0.00003387 43.394
prop-2-yn-1-ol 107-19-7 5 0.00001044 13.379
copolymer of 2-propenamide 69418-26-4 20 0.00605118 7752.48
Sodium Chloride 7647-14-5 10 0.000738223 945.776
Sodium Chloride 7647-14-5 100 0.00946732 12129.1
Sodium Nitrate 7631-99-4 5 0.000473366 606.454
Fatty imidazoline 61790-69-0 5 0.00001044 13.379
isopropyl alcohol 67-63-0 5 0.00001044 13.379
Inner Salt of Alkyl Amines Proprietary 60 0.00442934 5674.65
Polyacrylate Proprietary 30 0.011135 14265.6
Sodium Nitrate 7631-99-4 5 0.000473366 606.454
Distillates (petroleum), hydrotreated light 64742-47-8 20 0.00605118 7752.48
Hydrotreated Light Petroleum Distillate 64742-47-8 30 0.011135 14265.6
prop-2-yn-1-ol 107-19-7 5 0.00001044 13.379
Sodium Chloride 7647-14-5 10 0.000738223 945.776
2-ethylhexanol 104-76-7 5 0.00003387 43.394
Sodium Chloride 7647-14-5 5 0.00185583 2377.6
Fatty imidazoline 61790-69-0 5 0.00001044 13.379
Hydrochloric Acid 7647-01-0 15 0.0208336 26691
Inner Salt of Alkyl Amines Proprietary 60 0.00442934 5674.65
Ethoxylated Alcohol Proprietary 5 0.00185583 2377.6
Polyacrylate Proprietary 30 0.011135 14265.6
Calcium Nitrate.4H20 13477-34-4 100 0.106107 135939
ethylbenzene 100-41-4 1 0.00000209 2.676
xylene 1330-20-7 5 0.00001044 13.379
Hydrotreated Light Petroleum Distillate 64742-47-8 30 0.011135 14265.6
Sodium Chloride 7647-14-5 100 0.00946732 12129.1
methanol 67-56-1 30 0.00618532 7924.33
alcohols, C12-16, ethoxylated 68551-12-2 2 0.000605118 775.248
2-butoxyethanol 111-76-2 20 0.000135484 173.576
methanol 67-56-1 90 0.000187978 240.829
xylene 1330-20-7 5 0.00001044 13.379
Fatty Nitrogen Derived Amides Proprietary 5 0.00185583 2377.6
Silica Substrate 14808-60-7 100 12.9871 16,638,500.0
polyethylene glycol nonylphenyl ether, liquids 9016-45-9 25 0.000169355 216.97
2-butoxyethanol 111-76-2 20 0.000135484 173.576
Ethoxylated Alcohol Proprietary 5 0.00185583 2377.6
Fatty Nitrogen Derived Amides Proprietary 5 0.00185583 2377.6
polyethylene glycol nonylphenyl ether, liquids 9016-45-9 25 0.000169355 216.97
Sodium Chloride 7647-14-5 5 0.00185583 2377.6
Alcohols, C7-9iso-, C8-rich 68526-83-0 5 0.00001044 13.379
Alcohols, C7-9iso-, C8-rich 68526-83-0 5 0.00001044 13.379
oleic acid diethanolamide 93-83-4 2 0.000605118 775.248
ethylbenzene 100-41-4 1 0.00000209 2.676
Calcium Nitrate.4H20 13477-34-4 100 0.106107 135939

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2016 EQT PROD CO 0.00 0 0.00 0 0.00 0
2017 EQT PROD CO 2,075,299.00 159 0.00 0 0.00 0
2018 EQT PROD CO 1,085,389.00 338 0.00 0 0.00 0
2019 EQT PROD CO 477,524.00 340 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2017 EQT PROD CO Synthetic Liner Materials 4.25 Tons LANDFILL 100419
2017 EQT PROD CO Produced Fluid 624.24 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Other Oil & Gas Wastes 450.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Synthetic Liner Materials 41.11 Tons LANDFILL 100277
2017 EQT PROD CO Waste Water Treatment Sludge 50.18 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2017 EQT PROD CO Produced Fluid 9.96 Bbl INJECTION DISPOSAL WELL 34-031-27177
2017 EQT PROD CO Produced Fluid 1,852.01 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Drilling Fluid Waste 220.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 81.86 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2018 EQT PROD CO Produced Fluid 2.58 Bbl INJECTION DISPOSAL WELL 34-157-25511
2018 EQT PROD CO Other Oil & Gas Wastes 6.67 Bbl RESIDUAL WASTE PROCESSING FACILITY
2018 EQT PROD CO Other Oil & Gas Wastes 0.95 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Produced Fluid 206.87 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 1,687.10 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 5.90 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 EQT PROD CO Other Oil & Gas Wastes 2.38 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE ORDER 2016-415
2018 EQT PROD CO Other Oil & Gas Wastes 40.87 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Produced Fluid 30.93 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Other Oil & Gas Wastes 71.81 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 1.50 Bbl RESIDUAL WASTE PROCESSING FACILITY
2019 EQT PROD CO Produced Fluid 93.76 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2019 EQT PROD CO Other Oil & Gas Wastes 40.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 6.39 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Other Oil & Gas Wastes 15.72 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 25.73 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 42.72 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 841.95 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Other Oil & Gas Wastes 248.46 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 38.54 Bbl SURFACE IMPOUNDMENT 95-7-37312-19

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2484800 Primary Facility 2016-05-17 Drilling/Alteration No Violations Noted Cellar Tech auger rig

Drilled a 30” wellbore and set 26” conductor casing at 65 ft. on 5/17/16.

2518083 Primary Facility 2016-09-08 Drilling/Alteration No Violations Noted Alpha Hunter Drilling Rig #8

Moved onto this well on 9/1/16 and resumed drilling at 40 ft. on 9/3/16. The 18 5/8” casing was set at 379 ft. on 9/4/16 and cemented to surface with 45 bbls returned. The 13 3/8” casing was set at 477 ft. on 9/5/16 and cemented to surface with 5 bbls returned. Coal was found from 425 ft. to 430 ft. A basket was set at 389 ft. The 9 5/8” casing was set at 2089 ft. on 9/7/16 and cemented to surface with 25 bbls returned. A Casing Annulus Packer was set in the 9 5/8” casing string from 1264 ft. to 1287 ft. (with an 8 ft. pup joint above the packer). KOP was at 2164 ft. Currently at 2173 ft. and drilling ahead.

2546021 Primary Facility 2016-12-20 Drilling/Alteration No Violations Noted Pioneer Drilling Rig #72

Moved onto this well on 12/15/16 and resumed drilling at 5960 ft. MD KB. EOB was at 9968 ft. MD (7717.6 ft. TVD). Currently at 11,932 ft. MD and preparing to TOOH for new MWD tool.

2546707 Primary Facility 2016-12-21 Drilling/Alteration No Violations Noted Pioneer Drilling Rig #72

Currently at 12,861 ft. MD and drilling ahead.

2548586 Primary Facility 2016-12-29 Drilling/Alteration No Violations Noted Pioneer Drilling Rig #72

TD was at 17,079 ft. MD (7673.52 ft. TVD) on 12/24/16. The 5 ½” casing was set at 17,079 ft. Estimated TOC is at 6700 ft.

2549505 Primary Facility 2016-12-06 Routine/Partial Inspection No Violations Noted On 12/6/16, I performed a routine partial inspection of the Harold Haywood in response to observed activity on site and made the following observations:

•A drilling rig was being constructed on site at the time of inspection. •A large panel had been set on the pad near the juncture of the pad and access road with a chemical container, multiple metal drums, and multiple pieces of oil covered equipment. A small amount of oil had reached the pad surface. The situation was pointed out to site personnel and was then promptly remediated including removal of all visibly impacted pad material. No violation. •A coil of hose was also found off containment dripping oily material to the pad surface and was promptly removed. No violation.

2553003 Primary Facility 2016-12-16 Follow-up Inspection No Violations Noted On December 16, 2016 I performed a follow up inspection at the Howard Haywood site in response to concerns noted in a previous inspection (ID: 2549486) of the site on 12/6/16 and made the following observations:

•On 12/6/16 multiple issues with containment and minor spills were noted to site personnel and immediately remediated. •Near the junction of the site access road and the pad a large metal plate had been placed so that it was crushing and compromising the containment around multiple pallets of chemicals marked “AES Drilling Fluids”. Multiple other empty chemical storage containers were also found without any containment. This is a violation of 58 Pa. C.S. § 3218.2(d) for failing to provide containment with at least 110% capacity on regulated substances. •A spill of more than ten gallons of antifreeze was found off of containment near the drill rig. The situation was immediately communicated to site personnel for remediation. This constitutes a violation of 25 Pa. Code § 78.57(a) and 25 Pa. Code

2586955 Primary Facility 2017-04-26 Routine/Partial Inspection No Violations Noted On 4/24/17 a RTPT inspection was conducted of the Harold Haywood site. The following was observed.

>Multiple areas along the access road bear sparse or patchy vegetation increasing risk of erosion. No violation, remediation recommended.

>A topsoil pile near the pad entrance is only partially stabilized with straw. No violation, remediation recommended.

> Drilling activity was concluded at the time of inspection and removal of drilling and completion equipment was underway.

> The AST remained on site at time of inspection.

2688483 Primary Facility 2018-01-30 Routine/Complete Inspection No Violations Noted On 1/30/18 a routine complete of the Haywood Pad was conducted, the following was observed:

>>Substantial equipment was found stored around the site including multiple lifts and vehicles as well as numerous lights, generators, and tanks. An above ground storage tank was found on site as well. Most equipment had adequate secondary containment. Some stored equipment did not, any leaked or spilled fluids would constitute a violation.

>>Wells on site appeared to be in various stages of completion with no rig on site.

2698983 Primary Facility 2017-09-05 Administrative/File Review No Violations Noted On 9/5/17 an administrative inspection related to the Harold Haywood was conducted regarding test results related to complaint ID 328174. No evidence was found in the sample results suggesting impact to the water supply by oil and gas activity.
2722626 Primary Facility 2018-03-27 Complaint Inspection No Violations Noted On 3/27/18 a complaint inspection was conducted in relation to the Harold Haywood Well Site in response to CTS ID: 332966. Sample 3401-071 was collected for chemistry and biological analysis.
2767375 Primary Facility 2018-08-15 Routine/Partial Inspection No Violations Noted On 8/15/18 a routine partial inspection of the Harold Haywood Site was conducted in response to increased activity at the pad. The following was observed:

>>The site was in drilling phase at the time of inspection. High activity was noted on the pad. A drilling rig was active on site at the time of inspection.

>>Multiple containers of contaminated equipment were found off containment resulting in minor impacts to the pad. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the operator failed to control regulated materials in a manner that prevents pollution to the ground and Waters of the Commonwealth. Any equipment with the potential to cause pollution including equipment contaminated with petroleum residues should be placed and stored on containment. Runoff from improperly stored equipment will result in violations.

>>Staining found on the pad near the office trailer suspected to be petroleum based (material was hydrophobic and greasy). This constitutes a viola

2790121 Primary Facility 2018-05-01 Administrative/File Review No Violations Noted On 5/1/18 an administrative inspection related to the Haywood site was conducted to analyze results from sample 3401071 related to complaint ID 332966 collected on 3/27/18. Sample analysis found that while the water did not meet state drinking water standards no clear indicators of oil and gas impact were present.
2805721 Primary Facility 2018-11-02 Incident- Response to Accident or Event No Violations Noted On 11/2/18 a complaint inspection of the Harold Haywood well site was conducted in response an operator reported spill. The following was observed:

>>On 10/31/18 an EQT representative reported that 15 gallons of "impaired water" was spilled to the pad.

>>At the time of inspection an operator representative reported that the standing water along the bottom of the AST was found to have very high conductivity during a routine check. The impacted water was pumped out. Field testing of standing water at the time of inspection found water at the site of the initial spill remained impacted with conductivity reading at roughly 1040us. Per the representative the standing water at the time of inspection was believed to be rain water from storms after the initial spill. The impacted water at the time inspection was substantially greater than the 15 gallons initially reported and was in addition to the initial spill. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the opera

2831239 Primary Facility 2019-01-22 Compliance Evaluation No Violations Noted On 1/22/19 a compliance evaluation inspection of the Harold Haywood Well Site was conducted in response to violations recorded on 11/2/18 and 12/16/16. The following was observed:

>>No apparent residual impact related to spill violations from either date were observed. Containment around the AST on site may conceal further impact. No violation.

>>Violations related to non-GPU containment were remediated around time of 12/16/16 inspection and addressed with the operator at the time.

>>GPUs on site continued to lack containment at the time of inspection including on units installed post 10/2016. Violations ongoing.

2845253 Primary Facility 2019-02-19 Routine/Complete Inspection No Violations Noted Well and pad appear to be in good condition. There are 8 flow back tanks on site and 1 large water tank.
2863236 Primary Facility 2018-09-07 Administrative/File Review No Violations Noted On 9/7/18 an administrative inspection related to the Harold Haywood Pad was conducted to analyze sample and case information pertaining to a water supply complaint (CTS ID: 332966). No evidence of impact was found.

For data sources see[8]

References