X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-125-28011

Well Details

Well ID: 37-125-28011
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Carroll Township
Operator Name: EQT PROD CO
Well Pad ID: 147813
Farm/Lease Name: WERNER 592704
License Status:
Spud Date:
Permit Date: 2016-06-22
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.189433
Longitude: -79.937556

For data sources see[1][2][3]

Well History

Date Event
2016-06-22 New Permit Application
2016-08-09 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2017-03-03 2017-03-18 7,541 19,523,200 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 CS-500 SI FTS International Scale Inhibitor Listed Below
Water FTS International Carrier/Base Fluid Water 7732-18-5 100 88.5703 162,921,000.0
MC MX 8-2544 Multi-Chem Group Live Culture - Nitrate Reducing Bacteria Listed Below
Sand (Proppant) FTS International Proppant Listed Below
LD-2250 Multi-Chem Group Friction Reducer Listed Below
LD-2550 Multi-Chem Group Additive Listed Below
HVG-1 4.0 FTS International Water gelling agent Listed Below
Other Chemical(s) Listed Above See Trade Name(s) List Listed Below
FRW-900 FTS International Friction Reducer Listed Below
Hydrochloric Acid (15%) FTS International Acidizing Listed Below
MC MX 5-3886 Multi-Chem Group Specialty Brine Listed Below
CI-150 FTS International Acid Corrosion Inhibitor Listed Below
APB-1 FTS International Gel Breaker Listed Below
Ammonium Persulfate 7727-54-0 95 0.00000310 5.7
Hydrotreated Light Distillate 64742-47-8 30 0.00225936 4155.98
Quartz 14808-60-7 4 0.00000906 16.663
Quaternary ammonium compound Proprietary 10 0.00002291 42.134
Sodium chloride 7647-14-5 10 0.00103823 1909.77
Sodium chloride 7647-14-5 5 0.00295271 5431.37
Calcium nitrate.4H2O 13477-34-4 100 0.10777 198239
Sodium nitrate 7631-99-4 5 0.000483569 889.501
Quartz 14808-60-7 4 0.00000906 16.663
Ethylene Glycol 107-21-1 30 0.00006872 126.402
Oxyalkylated alcohol A Proprietary 5 0.00037656 692.664
Organic amine resin salt Proprietary 30 0.00006872 126.402
Alkyl Alcohol Proprietary 10 0.00075312 1385.33
Hydrotreated Light Distillate 64742-47-8 30 0.00225936 4155.98
Hydrochloric Acid 7647-01-0 15 0.0185675 34154
Ethoxylated alcohol Proprietary 5 0.00295271 5431.37
Ammonium Persulfate 7727-54-0 95 0.00000310 5.7
Dimethylformamide 68-12-2 10 0.00002291 42.134
Sodium chloride 7647-14-5 10 0.00103823 1909.77
Aromatic aldehyde Proprietary 10 0.00002291 42.134
Rraffinates, Sorption Process 64741-85-1 55 0.000124559 229.12
Guar gum 9000-30-0 50 0.000113236 208.291
Isopropanol 67-63-0 30 0.00006872 126.402
Silica Substrate 14808-60-7 100 11.0865 20,393,100.0
Hydrotreated light petroleum distillate 64742-47-8 30 0.0177163 32588.2
Rraffinates, Sorption Process 64741-85-1 55 0.000124559 229.12
Fatty nitrogen derived amides Proprietary 5 0.00295271 5431.37
Oxyalkylated alcohol A Proprietary 5 0.00037656 692.664
Polyacrylate Proprietary 30 0.0177163 32588.2
Fatty nitrogen derived amides Proprietary 5 0.00295271 5431.37
Sodium chloride 7647-14-5 100 0.00967137 17790
Guar gum 9000-30-0 50 0.000113236 208.291
Sodium nitrate 7631-99-4 5 0.000483569 889.501
Calcium nitrate.4H2O 13477-34-4 100 0.10777 198239
Sodium chloride 7647-14-5 5 0.00295271 5431.37
Polyacrylate Proprietary 30 0.0177163 32588.2
Sodium chloride 7647-14-5 100 0.00967137 17790
Inner salt of alkyl amines Proprietary 60 0.00622936 11458.6
Ethylene Glycol 107-21-1 10 0.00245916 4523.5
Isotridecanol, ethoxylated 9043-30-5 2 0.00000453 8.332
Inner salt of alkyl amines Proprietary 60 0.00622936 11458.6
Isotridecanol, ethoxylated 9043-30-5 2 0.00000453 8.332
Alkyl Alcohol Proprietary 10 0.00075312 1385.33

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2016 EQT PROD CO 0.00 0 0.00 0 0.00 0
2017 EQT PROD CO 3,645,217.00 224 0.00 0 0.00 0
2018 EQT PROD CO 3,093,812.00 364 0.00 0 0.00 0
2019 EQT PROD CO 1,935,883.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2017 EQT PROD CO Produced Fluid 4,623.82 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Other Oil & Gas Wastes 1,140.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Synthetic Liner Materials 42.01 Tons LANDFILL 100277
2017 EQT PROD CO Waste Water Treatment Sludge 31.02 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2017 EQT PROD CO Other Oil & Gas Wastes 100.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Produced Fluid 112.93 Bbl INJECTION DISPOSAL WELL 34-031-27177
2017 EQT PROD CO Produced Fluid 38.00 Bbl RESIDUAL WASTE PROCESSING FACILITY
2017 EQT PROD CO Produced Fluid 36,634.35 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 16.38 Bbl INJECTION DISPOSAL WELL 34-157-25511
2017 EQT PROD CO Produced Fluid 94.55 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2018 EQT PROD CO Produced Fluid 1,012.09 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 1,130.46 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 44.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Produced Fluid 187.56 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Other Oil & Gas Wastes 192.00 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 9.00 Bbl RESIDUAL WASTE PROCESSING FACILITY ODNR 2014-4
2018 EQT PROD CO Produced Fluid 17.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 EQT PROD CO Produced Fluid 59.16 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 30.76 Bbl INJECTION DISPOSAL WELL 2D0859721
2019 EQT PROD CO Produced Fluid 1,757.73 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 60.37 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Other Oil & Gas Wastes 11.00 Bbl INJECTION DISPOSAL WELL 34-105-23619
2019 EQT PROD CO Produced Fluid 4.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 99.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2019 EQT PROD CO Other Oil & Gas Wastes 89.40 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2509200 Primary Facility 2016-08-10 Drilling/Alteration No Violations Noted Cellar Tech auger rig

Drilled a 30” wellbore and set 26” conductor casing at 40 ft. on 8/9/16.

2513217 Primary Facility 2016-08-24 Drilling/Alteration No Violations Noted Alpha Hunter Drilling Rig #8

Moved onto this well on 8/24/16. Currently rigging up and preparing to resume drilling.

2514707 Primary Facility 2016-08-30 Drilling/Alteration No Violations Noted Alpha Hunter Drilling Rig #8

Moved onto this well on 8/24/16. The 18 5/8” casing was set at 127 ft. on 8/24/16 and cemented to surface with 30 bbls returned. The 13 3/8” casing was set at 259 ft. on 8/25/16 and cemented to surface with 5 bbls returned. Coal was found from 206 ft. to 209 ft. A basket was set at 165 ft. The 9 5/8” casing was set at 1651 ft. on 8/28/16 and cemented to surface with 60 bbls returned. A Casing Annulus Packer was set in the 9 5/8” casing string from 1247 ft. to 1269 ft. (with a 7 ft. pup joint above the packer and a 3 ft. pup joint below). Currently at 4350 ft. and TOOH to pick up directional BHA.

2531565 Primary Facility 2016-10-24 Drilling/Alteration No Violations Noted Patterson-UTI Drilling Rig #277

Moved onto this well on 10/21/16 and resumed drilling at 5576 ft. MD. Currently drilling ahead at 7652 ft. and building curve.

2538824 Primary Facility 2016-11-18 Drilling/Alteration No Violations Noted Patterson-UTI Drilling Rig #277

EOB on the curve was at 8723 ft. MD (7534 ft. TVD). TD was at 17,759 ft. MD (7535 ft. TVD) on 10/31/16. The 5 ½” casing was set at 17,958 ft. The estimated TOC is at 4785 ft.

2666250 Primary Facility 2017-11-28 Incident- Response to Accident or Event No Violations Noted On 11/28/17 an incident inspection of the Werner well site was conducted in response to a spill (CTS ID: 331105) reported on 11/23/17. The following was observed:

>>An area of disturbed earth near a juncture in the site access road was noted to be unstabilized at the time of inspection. No violation, remediation recommended.

>>The exact location of the spill was unable to be determined, operator contacts with detailed information were not available at the time of inspection. No violation, further information needed for determination.

2666906 Primary Facility 2017-12-01 Follow-up Inspection No Violations Noted On 12/1/17 an incident inspection of the Werner well site was conducted in response to a spill (CTS ID: 331105) reported on 11/23/17. The following was observed:

>>The initial report was of a truck rollover that resulted in an estimated spill of 20 gallons of oil to the roadside culvert. The spill was fully cleaned at the time of the initial inspection on 11/28/17 but the location of the spill was unable to be identified. Upon locating the site of the spill cleanup appears to be complete and without further impact. While this constitutes a violation of 25 Pa. Code 78.54 in the the operator failed to control fluids associated with well servicing it has been determined that the violation was immediately corrected.

>>The unstabilized disturbed area noted on 11/28/17 remained unstabilized at the time of inspection. Continued failure to provide temporary stabilization would constitute a violation under 25 Pa. Code 102.22(b)(1).

2666908 Primary Facility 2017-12-01 Follow-up Inspection No Violations Noted On 12/1/17 an incident inspection of the Werner well site was conducted in response to a spill (CTS ID: 331105) reported on 11/23/17. The following was observed:

>>The initial report was of a truck rollover that resulted in an estimated spill of 20 gallons of oil to the roadside culvert. The spill was fully cleaned at the time of the initial inspection on 11/28/17 but the location of the spill was unable to be identified. Upon locating the site of the spill cleanup appears to be complete and without further impact. While this constitutes a violation of 25 Pa. Code 78.54 in the the operator failed to control fluids associated with well servicing it has been determined that the violation was immediately corrected.

>>The unstabilized disturbed area noted on 11/28/17 remained unstabilized at the time of inspection. Continued failure to provide temporary stabilization would constitute a violation under 25 Pa. Code 102.22(b)(1).

2667079 Primary Facility 2017-12-04 Follow-up Inspection No Violations Noted On 12/4/17 an FUI inspection was conducted in response to concerns noted during a prior inspection on 12/1/17. The following was noted:

>>The unstabilized area of the site noted during a prior inspection on 12/1/17 had been stabilized at the time of inspection. No violation.

>>A small area between a section of CFS near the road juncture and the drainage channel was not stabilized. CFS at this location was also noted to be damaged. Remediation is recommended, no violation.

2686045 Primary Facility 2018-01-23 Administrative/File Review No Violations Noted On 1/23/18 an administrative inspection related to the Werner Well site was conducted in response to a complaint (CTS ID: 325462). The operator reported the complainant's concerns of potential pollution of a spring used as a partial water supply. Direct contact with the complainant found that the water had a history of methane contamination but no new or ongoing evidence of contamination. Further investigation by the DEP was declined at this time.
2708198 Primary Facility 2018-03-14 Routine/Complete Inspection No Violations Noted Well has been completed and is now producing.
2715909 Primary Facility 2018-04-06 Routine/Partial Inspection No Violations Noted On 4/6/18 a routine partial inspection of the Werner Well Site was conducted in response to an operator request for permit termination review of an adjacent site. The following was observed:

>>An area at the juncture of the access road and the access road of a nearby pipeline site was found to be unstabilized with partially constructed controls and early indications of increased erosion damage. No violation, stabilization in accordance with permit conditions is strongly recommended.

>>The adjacent Werner to Smith Pipeline was reported as unconstructed with regards to the permit termination request. Evidence of pipeline construction within the planned ROW was noted as related to a separate permit.

2725896 Primary Facility 2018-04-27 Follow-up Inspection No Violations Noted On 4/27/18 a follow up inspection of the Werner well site was conducted in response to issues first noted during a 4/6/18 routine partial inspection related to permit termination of an adjacent site. The following was observed:

>>The area noted in inspection report 2715873 as unstabilized and displaying increased erosion remained in much the same condition without surface stabilization. No indication of any work being conducted in the general area during the 21 days between inspections was found. This constitutes a violation of 25 Pa. Code § 102.22(b)(1) in that the operator failed to stabilize an area during any cessation of work in excess of four days.

2815118 Primary Facility 2018-12-13 Compliance Evaluation No Violations Noted On 12/13/18 a compliance evaluation inspection of the Werner Well Site was conducted in response to violations initially noted on 4/27/18. The following was observed:

> The unstabilized area of the site that was the subject of the violations was found to be fully vegetated and stabilized with site BMPs installed. An adjacent area of recent earth work was also stabilized. No further violations were found.

For data sources see[8]