If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-125-28021 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.189419,"lon":-79.937478,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Washington | |
Municipality: Carroll Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 147813 | |
Farm/Lease Name: WERNER 592703 | |
License Status: | |
Spud Date: | |
Permit Date: 2016-07-05 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 40.189419 | |
Longitude: -79.937478 |
Date | Event |
---|---|
2016-07-05 | New Permit Application |
2016-08-09 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2017-02-20 | 2017-03-02 | 7,545 | 14,448,900 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | MC MX 5-3886 | Multi-Chem Group | Specialty Brine | Listed Below | ||||
Water | FTS International | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 86.1297 | 120,576,000.0 | |
Sand (Proppant) | FTS International | Proppant | Listed Below | |||||
CI-150 | FTS International | Acid Corrosion Inhibitor | Listed Below | |||||
LD-2250 | Multi-Chem Group | Friction Reducer | Listed Below | |||||
CS-500 SI | FTS International | Scale Inhibitor | Listed Below | |||||
MC MX 8-2544 | Multi-Chem Group | Live Culture - Nitrate Reducing Bacteria | Listed Below | |||||
Alkyl Alcohol | Proprietary | 10 | 0.000194274 | 271.972 | ||||
Sodium nitrate | 7631-99-4 | 5 | 0.000475698 | 665.948 | ||||
Alkyl Alcohol | Proprietary | 10 | 0.000194274 | 271.972 | ||||
Ethoxylated alcohol | Proprietary | 5 | 0.00328496 | 4598.75 | ||||
Hydrotreated Light Distillate | 64742-47-8 | 30 | 0.000582822 | 815.916 | ||||
Sodium chloride | 7647-14-5 | 5 | 0.00328496 | 4598.75 | ||||
Ethoxylated alcohol | Proprietary | 5 | 0.00328496 | 4598.75 | ||||
Sodium chloride | 7647-14-5 | 5 | 0.00328496 | 4598.75 | ||||
Oxyalkylated alcohol A | Proprietary | 5 | 0.00009714 | 135.986 | ||||
Calcium nitrate.4H2O | 13477-34-4 | 100 | 0.105971 | 148352 | ||||
Sodium nitrate | 7631-99-4 | 5 | 0.000475698 | 665.948 | ||||
Quaternary ammonium compound | Proprietary | 10 | 0.00002774 | 38.829 | ||||
Inner salt of alkyl amines | Proprietary | 60 | 0.00733932 | 10274.6 | ||||
Polyacrylate | Proprietary | 30 | 0.0197098 | 27592.5 | ||||
Inner salt of alkyl amines | Proprietary | 60 | 0.00733932 | 10274.6 | ||||
Isopropanol | 67-63-0 | 30 | 0.00008321 | 116.488 | ||||
Sodium chloride | 7647-14-5 | 100 | 0.00951395 | 13319 | ||||
Calcium nitrate.4H2O | 13477-34-4 | 100 | 0.105971 | 148352 | ||||
Oxyalkylated alcohol A | Proprietary | 5 | 0.00009714 | 135.986 | ||||
Organic amine resin salt | Proprietary | 30 | 0.00008321 | 116.488 | ||||
Dimethylformamide | 68-12-2 | 10 | 0.00002774 | 38.829 | ||||
Fatty nitrogen derived amides | Proprietary | 5 | 0.00328496 | 4598.75 | ||||
Sodium chloride | 7647-14-5 | 10 | 0.00122322 | 1712.43 | ||||
Polyacrylate | Proprietary | 30 | 0.0197098 | 27592.5 | ||||
Sodium chloride | 7647-14-5 | 10 | 0.00122322 | 1712.43 | ||||
Hydrotreated light petroleum distillate | 64742-47-8 | 30 | 0.0197098 | 27592.5 | ||||
Hydrochloric Acid | 7647-01-0 | 15 | 0.0224833 | 31475.3 | ||||
Ethylene Glycol | 107-21-1 | 30 | 0.00008321 | 116.488 | ||||
Aromatic aldehyde | Proprietary | 10 | 0.00002774 | 38.829 | ||||
Silica Substrate | 14808-60-7 | 100 | 13.5007 | 18,900,200.0 | ||||
Ethylene Glycol | 107-21-1 | 10 | 0.00240736 | 3370.15 | ||||
Fatty nitrogen derived amides | Proprietary | 5 | 0.00328496 | 4598.75 | ||||
Hydrotreated Light Distillate | 64742-47-8 | 30 | 0.000582822 | 815.916 | ||||
Sodium chloride | 7647-14-5 | 100 | 0.00951395 | 13319 | ||||
Hydrotreated light petroleum distillate | 64742-47-8 | 30 | 0.0197098 | 27592.5 | ||||
FRW-900 | FTS International | Friction Reducer | Listed Below | |||||
LD-2550 | Multi-Chem Group | Additive | Listed Below | |||||
Other Chemical(s) | Listed Above | See Trade Name(s) List | Listed Below | |||||
Hydrochloric Acid (15%) | FTS International | Acidizing | Listed Below |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2016 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 2,346,690.00 | 245 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 1,998,660.00 | 343 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 1,154,366.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2017 | EQT PROD CO | Produced Fluid | 1,891.09 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | EQT PROD CO | Produced Fluid | 92.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 310.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Synthetic Liner Materials | 4.48 Tons | LANDFILL | 100277 |
2017 | EQT PROD CO | Waste Water Treatment Sludge | 31.02 Tons | RESIDUAL WASTE PROCESSING FACILITY | 2014-541 |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 330.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | EQT PROD CO | Produced Fluid | 82.54 Bbl | INJECTION DISPOSAL WELL | 34-031-27177 |
2017 | EQT PROD CO | Produced Fluid | 27.77 Bbl | RESIDUAL WASTE PROCESSING FACILITY | |
2017 | EQT PROD CO | Produced Fluid | 5,868.38 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Produced Fluid | 14.17 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017 | EQT PROD CO | Produced Fluid | 94.54 Tons | RESIDUAL WASTE PROCESSING FACILITY | 2014-541 |
2018 | EQT PROD CO | Produced Fluid | 802.96 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Produced Fluid | 586.11 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 44.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Produced Fluid | 142.55 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | EQT PROD CO | Synthetic Liner Materials | 4.50 Tons | LANDFILL | 100419 |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 173.00 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Produced Fluid | 6.56 Bbl | RESIDUAL WASTE PROCESSING FACILITY | ODNR 2014-4 |
2018 | EQT PROD CO | Produced Fluid | 12.52 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2019 | EQT PROD CO | Produced Fluid | 37.54 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Produced Fluid | 1,169.11 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 72.95 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019 | EQT PROD CO | Produced Fluid | 7.68 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 11.00 Bbl | INJECTION DISPOSAL WELL | 2D0859721 |
2019 | EQT PROD CO | Produced Fluid | 50.17 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 89.40 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2509199 | Primary Facility | 2016-08-10 | Drilling/Alteration | No Violations Noted | Cellar Tech auger rig
Drilled a 30” wellbore and set 26” conductor casing at 40 ft. on 8/9/16. |
2511401 | Primary Facility | 2016-08-18 | Drilling/Alteration | No Violations Noted | Alpha Hunter Drilling Rig #8
Moved onto this well on 8/15/16 and resumed drilling at 52 ft. KB on 8/17/16. The 18 5/8” casing was set at 126.49 ft. on 8/17/16 and cemented to surface with 40 bbls returned. Currently at 310 ft. and circulating to clean hole prior to TOOH and running 13 3/8” casing. |
2513214 | Primary Facility | 2016-08-24 | Drilling/Alteration | No Violations Noted | Alpha Hunter Drilling Rig #8
The 13 3/8” casing was set at 255 ft. on 8/18/16 and grouted to surface above the basket. Coal was found from 206 ft. to 209 ft. A basket was set at 167 ft. The 9 5/8” casing was set at 1651 ft. on 3/20/16 and cemented to surface with 60 bbls returned. A Casing Annulus Packer was set from 1246 ft. to 1669 ft. with a 5 ft. pup joint above and below the packer. KOP was at 5250ft. TD was at 5728 ft. on 8/23/16. |
2544039 | Primary Facility | 2016-12-09 | Drilling/Alteration | No Violations Noted | Patterson-UTI Drilling Rig #277
Moved onto this well on 12/1/16 and resumed drilling at 5743 ft. MD. KOP was at 5743 ft. (at 20¿). EOB was at 8506 ft. MD (7541 ft. TVD). TD was at 16,843 ft. MD (7524 ft. TVD) on 12/8/16. The 5 ½” casing was set at 16,799 ft. Estimated TOC is at 5070 ft. |
2666252 | Primary Facility | 2017-11-28 | Incident- Response to Accident or Event | No Violations Noted | On 11/28/17 an incident inspection of the Werner well site was conducted in response to a spill (CTS ID: 331105) reported on 11/23/17. The following was observed:
>>An area of disturbed earth near a juncture in the site access road was noted to be unstabilized at the time of inspection. No violation, remediation recommended. >>The exact location of the spill was unable to be determined, operator contacts with detailed information were not available at the time of inspection. No violation, further information needed for determination. |
2666911 | Primary Facility | 2017-12-01 | Follow-up Inspection | No Violations Noted | On 12/1/17 an incident inspection of the Werner well site was conducted in response to a spill (CTS ID: 331105) reported on 11/23/17. The following was observed:
>>The initial report was of a truck rollover that resulted in an estimated spill of 20 gallons of oil to the roadside culvert. The spill was fully cleaned at the time of the initial inspection on 11/28/17 but the location of the spill was unable to be identified. Upon locating the site of the spill cleanup appears to be complete and without further impact. While this constitutes a violation of 25 Pa. Code 78.54 in the the operator failed to control fluids associated with well servicing it has been determined that the violation was immediately corrected. >>The unstabilized disturbed area noted on 11/28/17 remained unstabilized at the time of inspection. Continued failure to provide temporary stabilization would constitute a violation under 25 Pa. Code 102.22(b)(1). |
2667081 | Primary Facility | 2017-12-04 | Follow-up Inspection | No Violations Noted | On 12/4/17 an FUI inspection was conducted in response to concerns noted during a prior inspection on 12/1/17. The following was noted:
>>The unstabilized area of the site noted during a prior inspection on 12/1/17 had been stabilized at the time of inspection. No violation. >>A small area between a section of CFS near the road juncture and the drainage channel was not stabilized. CFS at this location was also noted to be damaged. Remediation is recommended, no violation. |
2686048 | Primary Facility | 2018-01-23 | Administrative/File Review | No Violations Noted | On 1/23/18 an administrative inspection related to the Werner Well site was conducted in response to a complaint (CTS ID: 325462). The operator reported the complainant's concerns of potential pollution of a spring used as a partial water supply. Direct contact with the complainant found that the water had a history of methane contamination but no new or ongoing evidence of contamination. Further investigation by the DEP was declined at this time. |
2708193 | Primary Facility | 2018-03-14 | Routine/Complete Inspection | No Violations Noted | Well has been completed and is now producing. |
2715911 | Primary Facility | 2018-04-06 | Routine/Partial Inspection | No Violations Noted | On 4/6/18 a routine partial inspection of the Werner Well Site was conducted in response to an operator request for permit termination review of an adjacent site. The following was observed:
>>An area at the juncture of the access road and the access road of a nearby pipeline site was found to be unstabilized with partially constructed controls and early indications of increased erosion damage. No violation, stabilization in accordance with permit conditions is strongly recommended. >>The adjacent Werner to Smith Pipeline was reported as unconstructed with regards to the permit termination request. Evidence of pipeline construction within the planned ROW was noted as related to a separate permit. |
2725903 | Primary Facility | 2018-04-27 | Follow-up Inspection | No Violations Noted | On 4/27/18 a follow up inspection of the Werner well site was conducted in response to issues first noted during a 4/6/18 routine partial inspection related to permit termination of an adjacent site. The following was observed:
>>The area noted in inspection report 2715873 as unstabilized and displaying increased erosion remained in much the same condition without surface stabilization. No indication of any work being conducted in the general area during the 21 days between inspections was found. This constitutes a violation of 25 Pa. Code § 102.22(b)(1) in that the operator failed to stabilize an area during any cessation of work in excess of four days. |
2815121 | Primary Facility | 2018-12-13 | Compliance Evaluation | No Violations Noted | On 12/13/18 a compliance evaluation inspection of the Werner Well Site was conducted in response to violations initially noted on 4/27/18. The following was observed:
> The unstabilized area of the site that was the subject of the violations was found to be fully vegetated and stabilized with site BMPs installed. An adjacent area of recent earth work was also stabilized. No further violations were found. |
For data sources see[8]