X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-125-28074

Well Details

Well ID: 37-125-28074
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Carroll Township
Operator Name: EQT PROD CO
Well Pad ID: 148479
Farm/Lease Name: HAYWOOD 593789
License Status:
Spud Date:
Permit Date: 2016-11-29
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.178775
Longitude: -79.976008

For data sources see[1][2][3]

Well History

Date Event
2016-11-29 New Permit Application
2016-12-15 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2017-06-09 2017-06-27 7,346 12,128,000 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 KSI-19 Keane Scale Inhibitor Listed Below
MC MX 5-3886 Multi-Chem Specialty Brine Listed Below
Other Chemical(s) Listed Above See Trade Name(s) List water 7732-18-5 60 0.00001654 19.027
2-ethylhexanol 104-76-7 5 0.00000138 1.586
Fatty imidazoline 61790-69-0 5 0.00002080 23.926
ethylbenzene 100-41-4 1 0.00000416 4.785
2-ethylhexanol 104-76-7 5 0.00000138 1.586
polyethylene glycol nonylphenyl ether, liquids 9016-45-9 25 0.00000689 7.928
prop-2-yn-1-ol 107-19-7 5 0.00002080 23.926
Sodium Chloride 7647-14-5 100 0.00973931 11203
Fatty imidazoline 61790-69-0 5 0.00002080 23.926
prop-2-yn-1-ol 107-19-7 5 0.00002080 23.926
oleic acid diethanolamide 93-83-4 2 0.00127564 1467.35
xylene 1330-20-7 5 0.00002080 23.926
copolymer of 2-propenamide 69418-26-4 20 0.0127564 14673.5
Silica Substrate 14808-60-7 100 11.5378 13,271,800.0
Alcohols, C7-9iso-, C8-rich 68526-83-0 5 0.00002080 23.926
isopropyl alcohol 67-63-0 5 0.00002080 23.926
2-butoxyethanol 111-76-2 20 0.00000551 6.342
methanol 67-56-1 30 0.00621476 7148.74
Calcium Nitrate.4H20 13477-34-4 100 0.108423 124718
isopropyl alcohol 67-63-0 5 0.00002080 23.926
Hydrochloric Acid 7647-01-0 15 0.0411213 47301.3
xylene 1330-20-7 5 0.00002080 23.926
Calcium Nitrate.4H20 13477-34-4 100 0.108423 124718
polyethylene glycol nonylphenyl ether, liquids 9016-45-9 25 0.00000689 7.928
methanol 67-56-1 90 0.000374399 430.666
2-butoxyethanol 111-76-2 20 0.00000551 6.342
Sodium Nitrate 7631-99-4 5 0.000486966 560.15
ethylbenzene 100-41-4 1 0.00000416 4.785
Distillates (petroleum), hydrotreated light 64742-47-8 20 0.0127564 14673.5
Sodium Chloride 7647-14-5 100 0.00973931 11203
Sodium Nitrate 7631-99-4 5 0.000486966 560.15
methanol 67-56-1 90 0.000374399 430.666
alcohols, C12-16, ethoxylated 68551-12-2 2 0.00127564 1467.35
Alcohols, C7-9iso-, C8-rich 68526-83-0 5 0.00002080 23.926
KAI-12 Keane Acid Inhibitor Listed Below
Sand (Proppant) Keane Proppant Listed Below
KFR-Activator-1 Keane Activator Listed Below
MC MX 8-2544 Multi-Chem Live Culture - Nitrate Reducing Bacteria water 7732-18-5 60 0.00001654 19.027
Water Keane Carrier/Base Fluid Water 7732-18-5 100 87.9849 101,208,000.0
Hydrochloric Acid (15%) Keane Acidizing Listed Below
KFR-23 Keane Friction Reducer Water 7732-18-5 50 0.031891 36683.8

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2016 EQT PROD CO 0.00 0 0.00 0 0.00 0
2017 EQT PROD CO 1,889,147.00 151 0.00 0 0.00 0
2018 EQT PROD CO 1,994,220.00 326 0.00 0 0.00 0
2019 EQT PROD CO 1,332,228.00 363 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2017 EQT PROD CO Synthetic Liner Materials 1.32 Tons LANDFILL 100419
2017 EQT PROD CO Waste Water Treatment Sludge 50.18 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2017 EQT PROD CO Other Oil & Gas Wastes 380.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Other Oil & Gas Wastes 110.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Drilling Fluid Waste 2,080.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Drill Cuttings 2,054.99 Tons LANDFILL 100419
2017 EQT PROD CO Produced Fluid 1,014.16 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Drilling Fluid Waste 148.81 Bbl CENT WASTE TRT FAC NPDES EPA ID: 748-163
2017 EQT PROD CO Produced Fluid 12.85 Bbl INJECTION DISPOSAL WELL 34-031-27177
2017 EQT PROD CO Produced Fluid 1,443.05 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Drilling Fluid Waste 148.81 Bbl CENT WASTE TRT FAC NPDES DISCHARGE EPA ID: 748-163
2017 EQT PROD CO Produced Fluid 81.86 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2017 EQT PROD CO Synthetic Liner Materials 45.84 Tons LANDFILL 100663
2018 EQT PROD CO Other Oil & Gas Wastes 139.27 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 10.97 Bbl INJECTION DISPOSAL WELL 34-157-25511
2018 EQT PROD CO Other Oil & Gas Wastes 6.67 Bbl RESIDUAL WASTE PROCESSING FACILITY
2018 EQT PROD CO Other Oil & Gas Wastes 5.90 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 EQT PROD CO Produced Fluid 155.77 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 40.87 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 0.95 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Other Oil & Gas Wastes 2.38 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE ORDER 2016-415
2018 EQT PROD CO Produced Fluid 33.44 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Produced Fluid 1,237.84 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 37.88 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019 EQT PROD CO Other Oil & Gas Wastes 97.85 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 4.18 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2019 EQT PROD CO Produced Fluid 130.96 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 1,015.15 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Other Oil & Gas Wastes 159.56 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 3.29 Bbl RESIDUAL WASTE PROCESSING FACILITY
2019 EQT PROD CO Produced Fluid 1,268.67 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 32.29 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Produced Fluid 87.04 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2546023 Primary Facility 2016-12-20 Drilling/Alteration No Violations Noted Cellar Tech auger rig

Drilled a 30” wellbore and set 26” conductor casing at 65 ft. on 12/19/16.

2549513 Primary Facility 2016-12-06 Routine/Partial Inspection No Violations Noted On 12/6/16, I performed a routine partial inspection of the Harold Haywood in response to observed activity on site and made the following observations:

•A drilling rig was being constructed on site at the time of inspection. •A large panel had been set on the pad near the juncture of the pad and access road with a chemical container, multiple metal drums, and multiple pieces of oil covered equipment. A small amount of oil had reached the pad surface. The situation was pointed out to site personnel and was then promptly remediated including removal of all visibly impacted pad material. No violation. •A coil of hose was also found off containment dripping oily material to the pad surface and was promptly removed. No violation.

2553015 Primary Facility 2016-12-16 Follow-up Inspection No Violations Noted On December 16, 2016 I performed a follow up inspection at the Howard Haywood site in response to concerns noted in a previous inspection (ID: 2549486) of the site on 12/6/16 and made the following observations:

•On 12/6/16 multiple issues with containment and minor spills were noted to site personnel and immediately remediated. •Near the junction of the site access road and the pad a large metal plate had been placed so that it was crushing and compromising the containment around multiple pallets of chemicals marked “AES Drilling Fluids”. Multiple other empty chemical storage containers were also found without any containment. This is a violation of 58 Pa. C.S. § 3218.2(d) for failing to provide containment with at least 110% capacity on regulated substances. •A spill of more than ten gallons of antifreeze was found off of containment near the drill rig. The situation was immediately communicated to site personnel for remediation. This constitutes a violation of 25 Pa. Code § 78.57(a) and 25 Pa. Code

2564186 Primary Facility 2017-02-22 Drilling/Alteration No Violations Noted Pioneer Drilling Rig #72

Moved onto this well on 2/13/17 and resumed drilling at 88 ft. KB. The 18 5/8” casing was set at 390 ft. on 2/14/17 and cemented to surface with 25 bbls returned. The 13 3/8” casing was set at 483 ft. on 2/15/17 and grouted to surface above a basket. Coal was found from 432 ft. to 436 ft. A basket was set at 401 ft. The 9 5/8” casing was set at 2105 ft. on 2/18/17 and cemented to surface with 29 bbls returned. A Casing Annulus Packer was set in the 9 5/8” casing string from 1248 ft. to 1258 ft. KOP was at 2581 ft. Currently at 4969 ft. MD and TOOH to pick up fluid curve assembly.

2565515 Primary Facility 2017-02-15 Routine/Partial Inspection Violation(s) Noted On February 15, 2017 I conducted a routine inspection of the EQT Production Company (EQT) Harold Haywood well pad located in Carroll Township, Washington County. The focus of this inspection was the onsite processing of drill cuttings. Scott Boudreaux, Company Man, was present for EQT. Pioneer 72 rig had just finished drilling well #593789 to a depth of 533' and was cementing to surface the 13 3/8" casing (freshwater/coal). According to Mr. Boudreaux they were drilling on air and fresh water. Soap is added to help bring the cuttings up. The backyard was observed. BOS Solutions managed the drill cuttings through closed loop processing. The cuttings go through a series of shale shakers and centrifuges to remove excess liquid. The water is separated and reused. Lime is added to further dry the cuttings before being loaded into trucks for landfill disposal. Mr. Boudreaux stated they had not drilled with mud for approximately 3 days.
2569140 Primary Facility 2017-03-03 Drilling/Alteration No Violations Noted Pioneer Drilling Rig #72

EOB was at 9002 ft. MD (7344.72 ft. TVD). Currently at 17,793 ft. and drilling ahead.

2569143 Primary Facility 2017-03-07 Drilling/Alteration No Violations Noted Pioneer Drilling Rig #72

TD was at 18,873 ft. MD (7277 ft. TVD). The 5 ½” casing was set at 18,861 ft. on 3/6/17. Estimated TOC is at 5489 ft.

2587315 Primary Facility 2017-04-26 Routine/Partial Inspection No Violations Noted On 4/24/17 a RTPT inspection was conducted of the Harold Haywood site. The following was observed.

>Multiple areas along the access road bear sparse or patchy vegetation increasing risk of erosion. No violation, remediation recommended.

>A topsoil pile near the pad entrance is only partially stabilized with straw. No violation, remediation recommended.

> Drilling activity was concluded at the time of inspection and removal of drilling and completion equipment was underway.

> The AST remained on site at time of inspection.

2688496 Primary Facility 2018-01-30 Routine/Complete Inspection No Violations Noted On 1/30/18 a routine complete of the Haywood Pad was conducted, the following was observed:

>>Substantial equipment was found stored around the site including multiple lifts and vehicles as well as numerous lights, generators, and tanks. An above ground storage tank was found on site as well. Most equipment had adequate secondary containment. Some stored equipment did not, any leaked or spilled fluids would constitute a violation.

>>Wells on site appeared to be in various stages of completion with no rig on site.

2699005 Primary Facility 2017-09-05 Administrative/File Review No Violations Noted On 9/5/17 an administrative inspection related to the Harold Haywood was conducted regarding test results related to complaint ID 328174. No evidence was found in the sample results suggesting impact to the water supply by oil and gas activity.
2722773 Primary Facility 2018-03-27 Complaint Inspection No Violations Noted On 3/27/18 a complaint inspection was conducted in relation to the Harold Haywood Well Site in response to CTS ID: 332966. Sample 3401-071 was collected for chemistry and biological analysis.
2767385 Primary Facility 2018-08-15 Routine/Partial Inspection No Violations Noted On 8/15/18 a routine partial inspection of the Harold Haywood Site was conducted in response to increased activity at the pad. The following was observed:

>>The site was in drilling phase at the time of inspection. High activity was noted on the pad. A drilling rig was active on site at the time of inspection.

>>Multiple containers of contaminated equipment were found off containment resulting in minor impacts to the pad. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the operator failed to control regulated materials in a manner that prevents pollution to the ground and Waters of the Commonwealth. Any equipment with the potential to cause pollution including equipment contaminated with petroleum residues should be placed and stored on containment. Runoff from improperly stored equipment will result in violations.

>>Staining found on the pad near the office trailer suspected to be petroleum based (material was hydrophobic and greasy). This constitutes a viola

2790136 Primary Facility 2018-05-01 Administrative/File Review No Violations Noted On 5/1/18 an administrative inspection related to the Haywood site was conducted to analyze results from sample 3401071 related to complaint ID 332966 collected on 3/27/18. Sample analysis found that while the water did not meet state drinking water standards no clear indicators of oil and gas impact were present.
2805095 Primary Facility 2018-11-02 Complaint Inspection Violation(s) Noted On 11/2/18 a complaint inspection of the Harold Haywood well site was conducted in response an operator reported spill. The following was observed:

>>On 10/31/18 an EQT representative reported that 15 gallons of "impaired water" was spilled to the pad.

>>At the time of inspection an operator representative reported that the standing water along the bottom of the AST was found to have very high conductivity during a routine check. The impacted water was pumped out. Field testing of standing water at the time of inspection found water at the site of the initial spill remained impacted with conductivity reading at roughly 1040us. Per the representative the standing water at the time of inspection was believed to be rain water from storms after the initial spill. The impacted water at the time inspection was substantially greater than the 15 gallons initially reported and was in addition to the initial spill. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the opera

2831261 Primary Facility 2019-01-22 Compliance Evaluation No Violations Noted On 1/22/19 a compliance evaluation inspection of the Harold Haywood Well Site was conducted in response to violations recorded on 11/2/18 and 12/16/16. The following was observed:

>>No apparent residual impact related to spill violations from either date were observed. Containment around the AST on site may conceal further impact. No violation.

>>Violations related to non-GPU containment were remediated around time of 12/16/16 inspection and addressed with the operator at the time.

>>GPUs on site continued to lack containment at the time of inspection including on units installed post 10/2016. Violations ongoing.

2845268 Primary Facility 2019-02-19 Routine/Complete Inspection No Violations Noted Well and pad appear to be in good condition. There are 8 flow back tanks on site and 1 large water tank.
2863322 Primary Facility 2018-09-07 Administrative/File Review No Violations Noted On 9/7/18 an administrative inspection related to the Harold Haywood Pad was conducted to analyze sample and case information pertaining to a water supply complaint (CTS ID: 332966). No evidence of impact was found.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2565515 779438 2017-02-15 2017-05-19 78a64a(f) Environmental Health & Safety Residual waste including drilling mud, oil and grease, and water was observed on the ground inside containment areas around the drill rig, specifically around the backyard and cuttings handling areas. In some areas staining was observed on the well pad aggregate where the waste had escaped containm
2805095 833940 2018-11-02 78a64a(b) Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
779438 351475 NOV - Notice of Violation 2018-08-21
833940 366600 NOV - Notice of Violation

For data sources see[8]

References