X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-125-28075

Well Details

Well ID: 37-125-28075
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Carroll Township
Operator Name: EQT PROD CO
Well Pad ID: 148479
Farm/Lease Name: HAYWOOD 593809
License Status:
Spud Date:
Permit Date: 2016-11-29
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.1788
Longitude: -79.976019

For data sources see[1][2][3]

Well History

Date Event
2016-11-29 New Permit Application
2016-12-15 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2017-06-10 2017-06-26 7,347 11,301,200 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 KSI-19 Keane Scale Inhibitor Listed Below
Alcohols, C7-9iso-, C8-rich 68526-83-0 5 0.00002058 22.049
copolymer of 2-propenamide 69418-26-4 30 0.00000519 5.558
isopropyl alcohol 67-63-0 5 0.00002058 22.049
Petroleum Distillate 64742-47-8 20 0.00000346 3.705
Petroleum Distillate 64742-47-8 20 0.00000346 3.705
Fatty imidazoline 61790-69-0 5 0.00002058 22.049
Ammonium chloride ((NH4)CI) 12125-02-9 1 0.00000017 0.185
Sodium Chloride 7647-14-5 100 0.00974381 10436.8
Trade Secret Proprietary 10 0.00004132 44.262
Fatty imidazoline 61790-69-0 5 0.00002058 22.049
alcohols, C12-16, ethoxylated 68551-12-2 2 0.00000035 0.371
Solvent naphtha (petroleum) heavy aliph. 64742-96-7 60 0.000247937 265.571
Sodium Chloride 7647-14-5 100 0.00974381 10436.8
prop-2-yn-1-ol 107-19-7 5 0.00002058 22.049
Silica Substrate 14808-60-7 100 11.4833 12,300,000.0
copolymer of 2-propenamide 69418-26-4 20 0.0122496 13120.8
Hydrochloric Acid 7647-01-0 15 0.0404341 43309.9
Calcium Nitrate.4H20 13477-34-4 100 0.108436 116148
Distillates (petroleum), hydrotreated light 64742-47-8 20 0.0122496 13120.8
xylene 1330-20-7 5 0.00002058 22.049
Oleic Acid Diethanolamide 93-83-4 2 0.00000035 0.371
Sodium Nitrate 7631-99-4 5 0.00048719 521.842
ethylbenzene 100-41-4 1 0.00000412 4.41
Ammonium chloride ((NH4)CI) 12125-02-9 1 0.00000017 0.185
alcohols, C12-16, ethoxylated 68551-12-2 2 0.00000035 0.371
methanol 67-56-1 90 0.000370522 396.876
methanol 67-56-1 30 0.00613272 6568.91
Guar gum 9000-30-0 60 0.000247937 265.571
oleic acid diethanolamide 93-83-4 2 0.00122496 1312.08
Alcohols, C7-9iso-, C8-rich 68526-83-0 5 0.00002058 22.049
Oleic Acid Diethanolamide 93-83-4 2 0.00000035 0.371
Guar gum 9000-30-0 60 0.000247937 265.571
Sodium Nitrate 7631-99-4 5 0.00048719 521.842
Trade Secret Proprietary 10 0.00004132 44.262
prop-2-yn-1-ol 107-19-7 5 0.00002058 22.049
Solvent naphtha (petroleum) heavy aliph. 64742-96-7 60 0.000247937 265.571
alcohols, C12-16, ethoxylated 68551-12-2 2 0.00122496 1312.08
isopropyl alcohol 67-63-0 5 0.00002058 22.049
ethylbenzene 100-41-4 1 0.00000412 4.41
Calcium Nitrate.4H20 13477-34-4 100 0.108436 116148
xylene 1330-20-7 5 0.00002058 22.049
copolymer of 2-propenamide 69418-26-4 30 0.00000519 5.558
MC MX 5-3886 Multi-Chem Specialty Brine Listed Below
KAI-12 Keane Acid Inhibitor Listed Below
Hydrochloric Acid (15%) Keane Acidizing Listed Below
KFR-23 Keane Friction Reducer Water 7732-18-5 50 0.030624 32802.1
KFR-20 Keane Friction Reducer Listed Below
Other Chemical(s) Listed Above See Trade Name(s) List Water 7732-18-5 45 0.00000778 8.337
Sand (Proppant) Keane Proppant Listed Below
Water Keane Carrier/Base Fluid Water 7732-18-5 100 88.0465 94,308,800.0
KWG-111L Keane Gelling Agent Listed Below
MC MX 8-2544 Multi-Chem Live Culture - Nitrate Reducing Bacteria Water 7732-18-5 45 0.00000778 8.337

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2016 EQT PROD CO 0.00 0 0.00 0 0.00 0
2017 EQT PROD CO 1,237,857.00 141 0.00 0 0.00 0
2018 EQT PROD CO 1,938,515.00 348 0.00 0 0.00 0
2019 EQT PROD CO 1,304,751.00 363 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2017 EQT PROD CO Synthetic Liner Materials 58.04 Tons LANDFILL 100277
2017 EQT PROD CO Waste Water Treatment Sludge 50.18 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2017 EQT PROD CO Other Oil & Gas Wastes 440.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Drilling Fluid Waste 650.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Drill Cuttings 1,354.38 Tons LANDFILL 100419
2017 EQT PROD CO Produced Fluid 3,045.26 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Produced Fluid 9.83 Bbl INJECTION DISPOSAL WELL 34-031-27177
2017 EQT PROD CO Produced Fluid 545.98 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 81.86 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2017 EQT PROD CO Drilling Fluid Waste 780.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Produced Fluid 613.15 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 66.74 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 10.13 Bbl INJECTION DISPOSAL WELL 34-157-25511
2018 EQT PROD CO Other Oil & Gas Wastes 6.67 Bbl RESIDUAL WASTE PROCESSING FACILITY
2018 EQT PROD CO Other Oil & Gas Wastes 5.90 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 EQT PROD CO Other Oil & Gas Wastes 40.87 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 0.95 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Other Oil & Gas Wastes 2.38 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE ORDER 2016-415
2018 EQT PROD CO Produced Fluid 34.43 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Produced Fluid 1,444.76 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 41.18 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019 EQT PROD CO Other Oil & Gas Wastes 45.95 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Other Oil & Gas Wastes 57.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 89.35 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 75.88 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Other Oil & Gas Wastes 159.56 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 4.31 Bbl RESIDUAL WASTE PROCESSING FACILITY
2019 EQT PROD CO Produced Fluid 939.42 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 30.55 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Drilling Fluid Waste 0.10 Tons RESIDUAL WASTE PROCESSING FACILITY 301280
2019 EQT PROD CO Produced Fluid 226.90 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2546024 Primary Facility 2016-12-20 Drilling/Alteration No Violations Noted Cellar Tech auger rig

Drilled a 30” wellbore and set 26” conductor casing at 65 ft. on 12/19/16.

2549514 Primary Facility 2016-12-06 Routine/Partial Inspection No Violations Noted On 12/6/16, I performed a routine partial inspection of the Harold Haywood in response to observed activity on site and made the following observations:

•A drilling rig was being constructed on site at the time of inspection. •A large panel had been set on the pad near the juncture of the pad and access road with a chemical container, multiple metal drums, and multiple pieces of oil covered equipment. A small amount of oil had reached the pad surface. The situation was pointed out to site personnel and was then promptly remediated including removal of all visibly impacted pad material. No violation. •A coil of hose was also found off containment dripping oily material to the pad surface and was promptly removed. No violation.

2553016 Primary Facility 2016-12-16 Follow-up Inspection Violation(s) Noted On December 16, 2016 I performed a follow up inspection at the Howard Haywood site in response to concerns noted in a previous inspection (ID: 2549486) of the site on 12/6/16 and made the following observations:

•On 12/6/16 multiple issues with containment and minor spills were noted to site personnel and immediately remediated. •Near the junction of the site access road and the pad a large metal plate had been placed so that it was crushing and compromising the containment around multiple pallets of chemicals marked “AES Drilling Fluids”. Multiple other empty chemical storage containers were also found without any containment. This is a violation of 58 Pa. C.S. § 3218.2(d) for failing to provide containment with at least 110% capacity on regulated substances. •A spill of more than ten gallons of antifreeze was found off of containment near the drill rig. The situation was immediately communicated to site personnel for remediation. This constitutes a violation of 25 Pa. Code § 78.57(a) and 25 Pa. Code

2557428 Primary Facility 2017-01-25 Drilling/Alteration No Violations Noted Pioneer Drilling Rig #72

Moved onto this well on 1/20/17 and resumed drilling at 88 ft. KB. The 18 5/8” casing was set at 389 ft. on 1/22/17 and cemented to surface with 27 bbls returned. The 13 3/8” casing was set at 480 ft. on 1/24/17 and grouted to surface above a basket. Coal mine was found from 431 ft. to 440 ft. A basket was set at 411 ft. Currently at 520 ft. and nippling up BOP’s.

2560616 Primary Facility 2017-02-09 Drilling/Alteration No Violations Noted Pioneer Drilling Rig #72

The 9 5/8” casing was set at 2116 ft. on 1/28/17 and cemented to surface with 17 bbls returned. KOP was at 5054 ft. EOB was at 10,585 ft. MD (7345.57 ft. TVD). A Casing Annulus Packer was set in the 9 5/8” casing string. The top of the 10 ft. packer is at 1242 ft. Currently at 17,984 ft. and drilling ahead.

2564188 Primary Facility 2017-02-22 Drilling/Alteration No Violations Noted Pioneer Drilling Rig #72

TD was at 19,554 ft. MD (7279.78 ft. TVD) on 2/9/17. The 5 ½” casing was set at 19,554 ft. on 2/11/17. The estimated TOC is at 6000 ft.

2587317 Primary Facility 2017-04-26 Routine/Partial Inspection No Violations Noted On 4/24/17 a RTPT inspection was conducted of the Harold Haywood site. The following was observed.

>Multiple areas along the access road bear sparse or patchy vegetation increasing risk of erosion. No violation, remediation recommended.

>A topsoil pile near the pad entrance is only partially stabilized with straw. No violation, remediation recommended.

> Drilling activity was concluded at the time of inspection and removal of drilling and completion equipment was underway.

> The AST remained on site at time of inspection.

2688502 Primary Facility 2018-01-30 Routine/Complete Inspection No Violations Noted On 1/30/18 a routine complete of the Haywood Pad was conducted, the following was observed:

>>Substantial equipment was found stored around the site including multiple lifts and vehicles as well as numerous lights, generators, and tanks. An above ground storage tank was found on site as well. Most equipment had adequate secondary containment. Some stored equipment did not, any leaked or spilled fluids would constitute a violation.

>>Wells on site appeared to be in various stages of completion with no rig on site.

2699014 Primary Facility 2017-09-05 Administrative/File Review No Violations Noted On 9/5/17 an administrative inspection related to the Harold Haywood was conducted regarding test results related to complaint ID 328174. No evidence was found in the sample results suggesting impact to the water supply by oil and gas activity.
2722794 Primary Facility 2018-03-27 Complaint Inspection No Violations Noted On 3/27/18 a complaint inspection was conducted in relation to the Harold Haywood Well Site in response to CTS ID: 332966. Sample 3401-071 was collected for chemistry and biological analysis.
2790140 Primary Facility 2018-05-01 Administrative/File Review No Violations Noted On 5/1/18 an administrative inspection related to the Haywood site was conducted to analyze results from sample 3401071 related to complaint ID 332966 collected on 3/27/18. Sample analysis found that while the water did not meet state drinking water standards no clear indicators of oil and gas impact were present.
2805101 Primary Facility 2018-11-02 Complaint Inspection Violation(s) Noted On 11/2/18 a complaint inspection of the Harold Haywood well site was conducted in response an operator reported spill. The following was observed:

>>On 10/31/18 an EQT representative reported that 15 gallons of "impaired water" was spilled to the pad.

>>At the time of inspection an operator representative reported that the standing water along the bottom of the AST was found to have very high conductivity during a routine check. The impacted water was pumped out. Field testing of standing water at the time of inspection found water at the site of the initial spill remained impacted with conductivity reading at roughly 1040us. Per the representative the standing water at the time of inspection was believed to be rain water from storms after the initial spill. The impacted water at the time inspection was substantially greater than the 15 gallons initially reported and was in addition to the initial spill. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the opera

2831268 Primary Facility 2019-01-22 Compliance Evaluation No Violations Noted On 1/22/19 a compliance evaluation inspection of the Harold Haywood Well Site was conducted in response to violations recorded on 11/2/18 and 12/16/16. The following was observed:

>>No apparent residual impact related to spill violations from either date were observed. Containment around the AST on site may conceal further impact. No violation.

>>Violations related to non-GPU containment were remediated around time of 12/16/16 inspection and addressed with the operator at the time.

>>GPUs on site continued to lack containment at the time of inspection including on units installed post 10/2016. Violations ongoing.

2845272 Primary Facility 2019-02-19 Routine/Complete Inspection No Violations Noted Well and pad appear to be in good condition. There are 8 flow back tanks on site and 1 large water tank.
2863327 Primary Facility 2018-09-07 Administrative/File Review No Violations Noted On 9/7/18 an administrative inspection related to the Harold Haywood Pad was conducted to analyze sample and case information pertaining to a water supply complaint (CTS ID: 332966). No evidence of impact was found.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2553016 776668 2016-12-16 OGA3218.2(D) Environmental Health & Safety
2553016 776669 2016-12-16 78.54 Environmental Health & Safety
2553016 776670 2016-12-16 78.57(a) Environmental Health & Safety
2805101 833941 2018-11-02 78a64a(b) Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
776668 350277 NOV - Notice of Violation
776669 350277 NOV - Notice of Violation
776670 350277 NOV - Notice of Violation
833941 366600 NOV - Notice of Violation

For data sources see[8]

References