Well ID: 37-125-28125
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Carroll Township
Operator Name: EQT PROD CO
Well Pad ID: 145213
Farm/Lease Name: R SMITH 593774
License Status:
Spud Date:
Permit Date: 2016-11-09
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.164786
Longitude: -79.944372

For data sources see[1][2][3]

Well History

Date Event
2016-11-09 New Permit Application
2016-11-15 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2017-03-24 2017-05-25 7,326 13,076,100 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand (Proppant) FTS International Proppant Listed Below
MC MX 5-2349 Multi-Chem Friction Reducer Breaker Listed Below
LD-2250 Multi-Chem Friction Reducer Listed Below
LD-2550 Multi-Chem Additive Listed Below
MC MC 5-3886 Multi-Chem Specialty Brine Listed Below
MC MX 8-2544 Multi-Chem Live Culture - Nitrate Reducing Bacteria Listed Below
CI-150 FTS International Acid Corrosion Inhibitor Listed Below
FRW-950 FTS International Friction Reducer Listed Below
Other Chemical(s) Listed Above See Trade Name(s) List Listed Below
CS-500-SI FTS International Scale Inhibitor Listed Below
Hydrochloric Acid (15%) FTS International Acidizing Listed Below
Water FTS International Carrier/Base Fluid Water 7732-18-5 100 87.7607 109,120,000.0
Sodium Chloride 7647-14-5 10 0.00000215 2.679
Polyacrylate Proprietary 30 0.00287373 3573.14
Hydrotreated Light Petroleum Distillate 64742-47-8 30 0.00287373 3573.14
Isopropanol 67-63-0 30 0.000153486 190.842
Ethylene Glycol 107-21-1 13 0.00440239 5473.84
Sodium Chloride 7647-14-5 100 0.0800147 99488.6
Sodium Chloride 7647-14-5 5 0.000478955 595.523
Oxyalkylated Alcohol Proprietary 5 0.00177947 2212.55
Hydrochloric Acid 7647-01-0 15 0.0414723 51565.8
Fatty Nitrogen Derived Amides Proprietary 5 0.000478955 595.523
Ammonium Persulfate 7727-54-0 13 0.00440239 5473.84
Quaternary Ammonium Compound Proprietary 10 0.00005116 63.614
Calcium Nitrate 13477-34-4 100 0.00923637 11484.3
Hydrotreated Light Petroleum Distillate 64742-47-8 30 0.00287373 3573.14
Sodium Chloride 7647-14-5 5 0.00177947 2212.55
Ethoxylated Alcohol Proprietary 5 0.000478955 595.523
Inner Salt of Alkyl Amines Proprietary 60 0.00001293 16.074
Oxyalkylated Alcohol Proprietary 5 0.00177947 2212.55
Sodium Chloride 7647-14-5 5 0.00177947 2212.55
Fatty Nitrogen Derived Amides Proprietary 5 0.000478955 595.523
Ethylene Glycol 107-21-1 30 0.000153486 190.842
Inner Salt of Alkyl Amines Proprietary 60 0.00001293 16.074
Ethylene Glycol 107-21-1 10 0.00240071 2984.99
Calcium Nitrate 13477-34-4 100 0.00923637 11484.3
Sodium Chloride 7647-14-5 5 0.000478955 595.523
Hydrotreated Light Distillate 64742-47-8 30 0.0106768 13275.3
Sodium Chloride 7647-14-5 10 0.00000215 2.679
Sodium Nitrate 7631-99-4 5 0.00400074 4974.43
Organic Amine Resin Salt Proprietary 30 0.000153486 190.842
Ethylene Glycol 107-21-1 13 0.00440239 5473.84
Ethoxylated Alcohol Proprietary 5 0.000478955 595.523
Polyacrylate Proprietary 30 0.00287373 3573.14
Sodium Nitrate 7631-99-4 5 0.00400074 4974.43
Aromatic Aldehyde Proprietary 10 0.00005116 63.614
Dimethylformamide 68-12-2 10 0.00005116 63.614
Sodium Chloride 7647-14-5 100 0.0800147 99488.6
Silica Substrate 14808-60-7 100 11.77 14,634,600.0
Ammonium Persulfate 7727-54-0 13 0.00440239 5473.84

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2016 EQT PROD CO 0.00 0 0.00 0 0.00 0
2017 EQT PROD CO 1,001,301.00 125 0.00 0 0.00 0
2018 EQT PROD CO 2,148,485.00 365 0.00 0 0.00 0
2019 EQT PROD CO 1,136,627.00 322 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2017 EQT PROD CO Drill Cuttings 257.32 Tons LANDFILL 100172
2017 EQT PROD CO Produced Fluid 849.92 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Other Oil & Gas Wastes 810.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Other Oil & Gas Wastes 110.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2017 EQT PROD CO Waste Water Treatment Sludge 43.24 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2017 EQT PROD CO Produced Fluid 85.03 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2017 EQT PROD CO Drill Cuttings 555.86 Tons LANDFILL 100663
2017 EQT PROD CO Produced Fluid 178.09 Bbl INJECTION DISPOSAL WELL 34-031-27177
2017 EQT PROD CO Produced Fluid 31.75 Bbl RESIDUAL WASTE PROCESSING FACILITY
2017 EQT PROD CO Produced Fluid 2,353.42 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Drilling Fluid Waste 130.00 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 10.45 Bbl RESIDUAL WASTE PROCESSING FACILITY
2018 EQT PROD CO Other Oil & Gas Wastes 10.45 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Produced Fluid 1,185.31 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Produced Fluid 166.76 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 91.36 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Produced Fluid 94.71 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Other Oil & Gas Wastes 288.86 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 10.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 EQT PROD CO Produced Fluid 18.88 Bbl INJECTION DISPOSAL WELL 34-167-29543
2019 EQT PROD CO Produced Fluid 796.71 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 2.05 Bbl INJECTION DISPOSAL WELL 34-167-28462
2019 EQT PROD CO Produced Fluid 22.36 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Other Oil & Gas Wastes 59.41 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 33.94 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 8.95 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 13.44 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2019 EQT PROD CO Other Oil & Gas Wastes 222.95 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2538831 Primary Facility 2016-11-22 Drilling/Alteration No Violations Noted Cellar Tech auger rig

Drilled a 30” wellbore and set 26” conductor casing at 40 ft. on 11/16/16.

2538835 Primary Facility 2016-11-22 Drilling/Alteration No Violations Noted Alpha Hunter Drilling Rig #8

Moved onto this well on 11/16/16 and resumed drilling at 53 ft. KB. The 18 5/8” casing was set at 290 ft. on 11/17/16 and cemented to surface with 30 bbls returned. The 13 3/8” casing was set at 440 ft. on 11/18/16 and grouted to surface above the basket. Coal was found from 344 ft. to 352 ft. A basket was set at 300 ft. The 9 5/8” casing was set at 1675 ft. on 11/21/16 and cemented to surface with 20 bbls returned. A Casing Annulus Packer (CAP) was set in the 9 5/8” casing string from 1255 ft. to 1268 ft. (The CAP is approximately 10 ft. long with pup joints above and below.) Currently at 1725 ft. and drilling out plug.

2560619 Primary Facility 2017-02-09 Drilling/Alteration No Violations Noted Patterson-UTI Drilling Rig #277

Moved onto this well on 2/7/17 and resumed drilling at 5644 ft. KB MD. Currently at 7523 ft. and drilling ahead on tangent.

2564194 Primary Facility 2017-02-22 Drilling/Alteration No Violations Noted Patterson-UTI Drilling Rig #277

TD was at 19,872 ft. MD (7188 ft. TVD) on 2/15/17. The 5 ½” casing was set at 19,862 ft. The estimated TOC is at 4195 ft.

2614200 Primary Facility 2017-05-05 Incident- Response to Accident or Event In Compliance with Policy On 5/5/17 an INCDT inspection of the R. Smith well site was conducted in response to CTS ID: 326715. The following was observed:

>> Site was undergoing fracking at time of inspection.

>>The spill in question involved roughly 10 gallons of produced water being sprayed from from an overfilled accessory tank on the pad. Affected pad materials were collected and placed in a waste box on pad for disposal. No violation, site appears to be in compliance with policy.

>>Streaking was again noted on the outside of multiple production tanks similar to streaking noted in previous inspections.

2660196 Primary Facility 2017-11-09 Routine/Complete Inspection No Violations Noted On 11/10/17 a routine complete inspection of the R. Smith well site was conducted in response to notification additional drilling on site. The following was observed:

>>A box tank was found near the impoundment with no containment. Remediation recommended, no violation.

>>A new top soil stock pile was noted on site. It was stabilized with straw at the time of inspection.

>>The soil stock pile was noted to not have any functional controls below it other than an adequate vegetated strip. Decomposed CFS should be removed, repaired, or replaced. No violation.

>>Drilling was ongoing at the site at the time of inspection.

2691621 Primary Facility 2018-02-02 Routine/Complete Inspection No Violations Noted Well has been fracked and is producing.
2705701 Primary Facility 2018-03-13 Routine/Partial Inspection No Violations Noted On 3/14/18 a routine complete inspection of the R. Smith Well Site was conducted in response to a notification of proposed construction activity on the pad. The following was observed:

>>The site was in a high activity phase at the time of inspection drilling appeared to be completed and the site was in apparent transition to post drilling activities. No drilling rig was present on site at the time of inspection.

>>Construction of a proposed AST had not begun at the time of inspection.

>>Many water trucks were present on site in association with the attached impoundment.

2738544 Primary Facility 2018-05-16 Incident- Response to Accident or Event No Violations Noted On 5/16/18 an incident inspection of the R. Smith well site was conducted in response to a spill reported by the operator on 5/14/18. The following was observed:

>>The operator reported that roughly 35 gallons of mixed rain water and produced water was spilled to the pad when a section of containment was moved without being drained first. Fluids were spread over a large area of the pad along the area in front of the production units per discussion with Mike Cromley at the time of inspection. This does constitute a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the operator failed to control regulated materials in a manner that prevents prevents pollution to the ground or Waters of the Commonwealth however, the violation is regarded as immediately corrected.

>>Site inspection found no residual evidence of the spill. The operator reported that all visibly impacted gravel from the spill area had been removed (roughly two clamshell dumpsters).

2747229 Primary Facility 2018-06-29 Routine/Partial Inspection No Violations Noted On 6/29/18 a routine partial inspection of the R. Smith Well Site was conducted in response to concerns about runoff raised by a nearby resident. The following was observed:

>>An unstabilized soil pile near the corner of the pad with a newly improved drain. Controls below the pile were absent though the vegetation was sufficient. No violation, remediation recommended.

>>Another only partially stabilized soil pile with no controls below the pile was located along the accessory pad access road. No controls beyond vegetation were present below the soil pile. No violation, monitoring recommended.

>>An AST was present on the accessory pad.

>>The pad was active at the time of inspection with drilling preparations ongoing. A sound wall was present around the pad perimeter.

2761987 Primary Facility 2018-08-02 Routine/Complete Inspection No Violations Noted On 8/2/18 a complaint response inspection was conducted of the R Smith well site in response to reported concerns of inappropriate drainage from the pad. WQSS John Carson accompanied. The following was observed:

>>A top soil pile on the access road to the accessory pad remained lacking vegetation and with spotty temporary stabilization. The vegetative strip below remains in good condition. Remediation recommended, no violation.

>>Emptying partially filled containment is encouraged to aid in identifying any possible leaks. No violation.

>>No evidence of excessive or unpermitted runoff from the pad was found.

>>Box in containment appears to be collecting emergency blowdown. If so it should be properly marked. No violation.

For data sources see[8]