Well ID: 37-125-28287 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.178831,"lon":-79.976036,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Washington | |
Municipality: Carroll Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 148479 | |
Farm/Lease Name: HAYWOOD MON110H24 | |
License Status: | |
Spud Date: | |
Permit Date: 2017-08-07 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 40.178831 | |
Longitude: -79.976036 |
Date | Event |
---|---|
2017-08-07 | New Permit Application |
2018-02-07 | MOD |
2018-04-05 | Performed Spud Operation |
2018-06-05 | MOD |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2018-10-16 | 2018-10-27 | 7,338 | 6,295,880 | 0 |
2 | 2018-10-15 | 2018-11-10 | 7,332 | 22,987,200 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Sand (Proppant) | FTSI | Proppant | Listed Below | ||||
Other Chemical(s) | Listed Above | See Trade Name(s) List | Listed Below | |||||
Hydrochloric Acid (15%) | FTSI | Acidizing | Listed Below | |||||
Water | FTSI | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 87.0576 | 52,539,200.0 | |
BIOC111139A | FTSI | Biocide | Listed Below | |||||
Aromatic aldehyde | Proprietary | 10 | 0.00005613 | 33.872 | ||||
Phosphonic Acid, {Nitrilotris (methylene)} Tris | 6419-19-8 | 35 | 0.0085407 | 5154.31 | ||||
Distillates (petroleum), hydrotreated light | 64742-47-8 | 30 | 0.017184 | 10370.5 | ||||
Distillates (petroleum), hydrotreated light | 64742-47-8 | 30 | 0.017184 | 10370.5 | ||||
Aromatic aldehyde | Proprietary | 10 | 0.00005613 | 33.872 | ||||
Phosphorous Acid | 10294-56-1 | 2 | 0.00048804 | 294.532 | ||||
Organic amine resin salt | Proprietary | 30 | 0.00016838 | 101.617 | ||||
Phosphonic Acid, {(Dimethylamino) Methylene} Bis - | 29712-30-9 | 5 | 0.0012201 | 736.329 | ||||
Silica Substrate | 14808-60-7 | 100 | 12.5046 | 7,546,490.0 | ||||
Dimethylformamide | 68-12-2 | 10 | 0.00005613 | 33.872 | ||||
Alcohols, C11-14-iso-, C13-rich, ethoxylated | 78330-21-9 | 5 | 0.00286399 | 1728.42 | ||||
Ethanol | 64-17-5 | 5 | 0.00105706 | 637.937 | ||||
Quaternary ammonium compound | Proprietary | 10 | 0.00005613 | 33.872 | ||||
Ethylene Glycol | 107-21-1 | 30 | 0.00016838 | 101.617 | ||||
Isopropanol | 67-63-0 | 30 | 0.00016838 | 101.617 | ||||
Phosphonic Acid, {Nitrilotris (methylene)} Tris | 6419-19-8 | 35 | 0.0085407 | 5154.31 | ||||
Phosphorous Acid | 10294-56-1 | 2 | 0.00048804 | 294.532 | ||||
Hydrochloric Acid | 7647-01-0 | 15 | 0.0501738 | 30279.8 | ||||
Organic amine resin salt | Proprietary | 30 | 0.00016838 | 101.617 | ||||
Benzyl-(C12-C16 Alkyl)-Dimethyl-Ammonium Chloride | 68424-85-1 | 30 | 0.00634239 | 3827.62 | ||||
Dimethylformamide | 68-12-2 | 10 | 0.00005613 | 33.872 | ||||
Ethylene Glycol | 107-21-1 | 30 | 0.00016838 | 101.617 | ||||
Alcohols, C11-14-iso-, C13-rich, ethoxylated | 78330-21-9 | 5 | 0.00286399 | 1728.42 | ||||
Glutaralehyde | 111-30-8 | 10 | 0.00211413 | 1275.88 | ||||
Phosphonic Acid, {(Dimethylamino) Methylene} Bis - | 29712-30-9 | 5 | 0.0012201 | 736.329 | ||||
Quaternary ammonium compound | Proprietary | 10 | 0.00005613 | 33.872 | ||||
CS-1000 | FTSI | Scale Inhibitor | Listed Below | |||||
CI-150 | FTSI | Acid Corrosion Inhibitor | Listed Below | |||||
FRW-1450 | FTSI | Polymer | Listed Below | |||||
2 | Sand (Proppant) | FTSI | Proppant | Listed Below | ||||
EMC PP | EMC | Pipe on pipe | Listed Below | |||||
Water | FTSI | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 88.7274 | 191,828,000.0 | |
Phosphonic Acid, {(Dimethylamino) Methylene} Bis - | 29712-30-9 | 5 | 0.000864614 | 1869.29 | ||||
Organic amine resin salt | Proprietary | 30 | 0.000151322 | 327.157 | ||||
Butyl cellozolve | Proprietary | 5 | 0.00010813 | 233.776 | ||||
Alcohols, C11-14-iso-, C13-rich, ethoxylated | 78330-21-9 | 5 | 0.00322607 | 6974.75 | ||||
Ethanol | 64-17-5 | 5 | 0.00105661 | 2284.39 | ||||
Phosphorous Acid | 10294-56-1 | 2 | 0.000345846 | 747.717 | ||||
Isopropanol | 67-63-0 | 30 | 0.000151322 | 327.157 | ||||
Phosphonic Acid, {(Dimethylamino) Methylene} Bis - | 29712-30-9 | 5 | 0.000864614 | 1869.29 | ||||
Alcohols, C11-14-iso-, C13-rich, ethoxylated | 78330-21-9 | 5 | 0.00322607 | 6974.75 | ||||
Aromatic aldehyde | Proprietary | 10 | 0.00005044 | 109.052 | ||||
Ethylene Glycol | 107-21-1 | 30 | 0.000151322 | 327.157 | ||||
Phosphorous Acid | 10294-56-1 | 2 | 0.000345846 | 747.717 | ||||
Petroleum Naphtha | 64742-47-8 | 80 | 0.00173007 | 3740.41 | ||||
Amides, From Diethylenetriamone, alkenoic Acid and tall oil fatty acids |
Proprietary | 20 | 0.000432518 | 935.103 | ||||
Glutaralehyde | 111-30-8 | 10 | 0.00211322 | 4568.78 | ||||
Benzyl-(C12-C16 Alkyl)-Dimethyl-Ammonium Chloride | 68424-85-1 | 30 | 0.00633967 | 13706.3 | ||||
Quaternary ammonium compound | Proprietary | 10 | 0.00005044 | 109.052 | ||||
Aromatic aldehyde | Proprietary | 10 | 0.00005044 | 109.052 | ||||
Hydrochloric Acid | 7647-01-0 | 15 | 0.0450909 | 97486.3 | ||||
Butyl cellozolve | Proprietary | 5 | 0.00010813 | 233.776 | ||||
Distillates (petroleum), hydrotreated light | 64742-47-8 | 30 | 0.0193564 | 41848.5 | ||||
Organic amine resin salt | Proprietary | 30 | 0.000151322 | 327.157 | ||||
Silica Substrate | 14808-60-7 | 100 | 10.8663 | 23,493,000.0 | ||||
Phosphonic Acid, {Nitrilotris (methylene)} Tris | 6419-19-8 | 35 | 0.0060523 | 13085 | ||||
Petroleum Naphtha | 64742-47-8 | 80 | 0.00173007 | 3740.41 | ||||
Ethylene Glycol | 107-21-1 | 30 | 0.000151322 | 327.157 | ||||
Quaternary ammonium compound | Proprietary | 10 | 0.00005044 | 109.052 | ||||
Phosphonic Acid, {Nitrilotris (methylene)} Tris | 6419-19-8 | 35 | 0.0060523 | 13085 | ||||
Dimethylformamide | 68-12-2 | 10 | 0.00005044 | 109.052 | ||||
Amides, From Diethylenetriamone, alkenoic Acid and tall oil fatty acids |
Proprietary | 20 | 0.000432518 | 935.103 | ||||
Distillates (petroleum), hydrotreated light | 64742-47-8 | 30 | 0.0193564 | 41848.5 | ||||
CS-1000 | FTSI | Scale Inhibitor | Listed Below | |||||
CI-150 | FTSI | Acid Corrosion Inhibitor | Listed Below | |||||
FRW-1450 | FTSI | Polymer | Listed Below | |||||
Other Chemical(s) | Listed Above | See Trade Name(s) List | Listed Below | |||||
BIOC111139A | FTSI | Biocide | Listed Below | |||||
Hydrochloric Acid (15%) | FTSI | Acidizing | Listed Below |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2019 | EQT PROD CO | 1,811,640.00 | 358 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2018 | EQT PROD CO | Other Oil & Gas Wastes | 0.95 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 4.84 Tons | LANDFILL | 100419 |
2018 | EQT PROD CO | Drilling Fluid Waste | 650.00 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Drill Cuttings | 1,020.14 Tons | LANDFILL | 100277 |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 5.90 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 2.38 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ORDER 2016-415 |
2018 | EQT PROD CO | Produced Fluid | 96.22 Tons | RESIDUAL WASTE PROCESSING FACILITY | 2014-541 |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 34.76 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 39.75 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Synthetic Liner Materials | 3.50 Tons | LANDFILL | 100277 |
2018 | EQT PROD CO | Produced Fluid | 0.08 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301280 |
2019 | EQT PROD CO | Produced Fluid | 38.94 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2019 | EQT PROD CO | Produced Fluid | 4.80 Bbl | RESIDUAL WASTE PROCESSING FACILITY | |
2019 | EQT PROD CO | Produced Fluid | 42.22 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019 | EQT PROD CO | Produced Fluid | 64.25 Bbl | LANDFILL | SWF 1032-WV0109 |
2019 | EQT PROD CO | Produced Fluid | 7,653.76 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 19.60 Tons | RESIDUAL WASTE PROCESSING FACILITY | ODNR 2015-511 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 72.19 Bbl | LANDFILL | 100172 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 40.71 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Synthetic Liner Materials | 10.01 Tons | LANDFILL | 100277 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 10.48 Bbl | LANDFILL | SWF 1032-WV0109 |
2019 | EQT PROD CO | Produced Fluid | 421.91 Bbl | LANDFILL | 100172 |
2019 | EQT PROD CO | Produced Fluid | 87.66 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Waste Water Treatment Sludge | 160.03 Tons | STORAGE PENDING DISPOSAL OR REUSE | MID0209062814 |
2019 | EQT PROD CO | Produced Fluid | 16.71 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2019 | EQT PROD CO | Produced Fluid | 2,212.27 Bbl | LANDFILL | 100663 |
2019 | EQT PROD CO | Synthetic Liner Materials | 27.43 Tons | LANDFILL | 100419 |
2019 | EQT PROD CO | Produced Fluid | 222.77 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 227.04 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2587321 | Primary Facility | 2017-04-26 | Routine/Partial Inspection | No Violations Noted | On 4/24/17 a RTPT inspection was conducted of the Harold Haywood site. The following was observed.
>Multiple areas along the access road bear sparse or patchy vegetation increasing risk of erosion. No violation, remediation recommended. >A topsoil pile near the pad entrance is only partially stabilized with straw. No violation, remediation recommended. > Drilling activity was concluded at the time of inspection and removal of drilling and completion equipment was underway. > The AST remained on site at time of inspection. |
2688508 | Primary Facility | 2018-01-30 | Routine/Complete Inspection | No Violations Noted | On 1/30/18 a routine complete of the Haywood Pad was conducted, the following was observed:
>>Substantial equipment was found stored around the site including multiple lifts and vehicles as well as numerous lights, generators, and tanks. An above ground storage tank was found on site as well. Most equipment had adequate secondary containment. Some stored equipment did not, any leaked or spilled fluids would constitute a violation. >>Wells on site appeared to be in various stages of completion with no rig on site. |
2699030 | Primary Facility | 2017-09-05 | Administrative/File Review | No Violations Noted | On 9/5/17 an administrative inspection related to the Harold Haywood was conducted regarding test results related to complaint ID 328174. No evidence was found in the sample results suggesting impact to the water supply by oil and gas activity. |
2715257 | Primary Facility | 2018-04-06 | Drilling/Alteration | No Violations Noted | Cellar Tech auger rig drilled a 30" well bore and set 26" conductor casing at 40 ft. on 4/5/18. |
2719525 | Primary Facility | 2018-04-18 | Drilling/Alteration | No Violations Noted | Falcon Drilling Rig #20 moved onto this well on 4/14/18 and resumed drilling at 52 ft. KB on 4/16/18. The 18 5/8" casing was set at 384 ft. on 4/16/18 and cemented to surface with 45 bbls returned. The 13 3/8" casing was set at 467 ft. on 4/17/18 and cemented to surface with36 bbls returned. Coal was found from 422 ft. To 430 ft. A basket was set at 387 ft. Currently at 520 ft. and nippling up BOP's. |
2722801 | Primary Facility | 2018-03-27 | Complaint Inspection | No Violations Noted | On 3/27/18 a complaint inspection was conducted in relation to the Harold Haywood Well Site in response to CTS ID: 332966. Sample 3401-071 was collected for chemistry and biological analysis. |
2723585 | Primary Facility | 2018-04-26 | Drilling/Alteration | No Violations Noted | Falcon Drilling Rig #20. The 9 5/8" casing was set at 2093 ft. on 4/20/18 and cemented to surface with 23 bbls returned. TD was at 5350 ft. on 4/23/18. |
2760871 | Primary Facility | 2018-08-07 | Drilling/Alteration | No Violations Noted | Patterson-UTI Drilling Rig #294 began moving onto location on 8/1/18 and moved onto this well on 8/5/18. Currently rigging up and preparing to resume drilling. |
2762720 | Primary Facility | 2018-08-13 | Drilling/Alteration | No Violations Noted | Patterson-UTI Drilling Rig #294 resumed drilling at 5368 ft. KB on 8/9/18. KOP was at 6158 ft. EOB was at 7932 ft. MD (7332 ft. TVD). Currently at 12,241 ft. and drilling ahead. |
2767035 | Primary Facility | 2018-08-24 | Drilling/Alteration | No Violations Noted | Patterson-UTI Drilling Rig #294. TD was at 13,540 ft. MD (7317 ft. TVD) on 8/13/18. The 5 1/2" casing was set at 13,538 ft. Estimated TOC at 5000 ft. |
2767391 | Primary Facility | 2018-08-15 | Routine/Partial Inspection | No Violations Noted | On 8/15/18 a routine partial inspection of the Harold Haywood Site was conducted in response to increased activity at the pad. The following was observed:
>>The site was in drilling phase at the time of inspection. High activity was noted on the pad. A drilling rig was active on site at the time of inspection. >>Multiple containers of contaminated equipment were found off containment resulting in minor impacts to the pad. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the operator failed to control regulated materials in a manner that prevents pollution to the ground and Waters of the Commonwealth. Any equipment with the potential to cause pollution including equipment contaminated with petroleum residues should be placed and stored on containment. Runoff from improperly stored equipment will result in violations. >>Staining found on the pad near the office trailer suspected to be petroleum based (material was hydrophobic and greasy). This constitutes a viola |
2790142 | Primary Facility | 2018-05-01 | Administrative/File Review | No Violations Noted | On 5/1/18 an administrative inspection related to the Haywood site was conducted to analyze results from sample 3401071 related to complaint ID 332966 collected on 3/27/18. Sample analysis found that while the water did not meet state drinking water standards no clear indicators of oil and gas impact were present. |
2805063 | Primary Facility | 2018-11-02 | Complaint Inspection | Violation(s) Noted | On 11/2/18 a complaint inspection of the Harold Haywood well site was conducted in response an operator reported spill. The following was observed:
>>On 10/31/18 an EQT representative reported that 15 gallons of "impaired water" was spilled to the pad. >>At the time of inspection an operator representative reported that the standing water along the bottom of the AST was found to have very high conductivity during a routine check. The impacted water was pumped out. Field testing of standing water at the time of inspection found water at the site of the initial spill remained impacted with conductivity reading at roughly 1040us. Per the representative the standing water at the time of inspection was believed to be rain water from storms after the initial spill. The impacted water at the time inspection was substantially greater than the 15 gallons initially reported and was in addition to the initial spill. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the opera |
2831222 | Primary Facility | 2019-01-22 | Compliance Evaluation | No Violations Noted | On 1/22/19 a compliance evaluation inspection of the Harold Haywood Well Site was conducted in response to violations recorded on 11/2/18 and 12/16/16. The following was observed:
>>No apparent residual impact related to spill violations from either date were observed. Containment around the AST on site may conceal further impact. No violation. >>Violations related to non-GPU containment were remediated around time of 12/16/16 inspection and addressed with the operator at the time. >>GPUs on site continued to lack containment at the time of inspection including on units installed post 10/2016. Violations ongoing. |
2863340 | Primary Facility | 2018-09-07 | Administrative/File Review | No Violations Noted | On 9/7/18 an administrative inspection related to the Harold Haywood Pad was conducted to analyze sample and case information pertaining to a water supply complaint (CTS ID: 332966). No evidence of impact was found. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2805063 | 833939 | 2018-11-02 | 78a64a(b) | Environmental Health & Safety |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
833939 | 366600 | NOV - Notice of Violation |