37-125-28287

Well Details

Well ID: 37-125-28287
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Carroll Township
Operator Name: EQT PROD CO
Well Pad ID: 148479
Farm/Lease Name: HAYWOOD MON110H24
License Status:
Spud Date:
Permit Date: 2017-08-07
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.178831
Longitude: -79.976036

For data sources see[1][2][3]

Well History

Date Event
2017-08-07 New Permit Application
2018-02-07 MOD
2018-04-05 Performed Spud Operation
2018-06-05 MOD

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2018-10-16 2018-10-27 7,338 6,295,880 0
2 2018-10-15 2018-11-10 7,332 22,987,200 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand (Proppant) FTSI Proppant Listed Below
Other Chemical(s) Listed Above See Trade Name(s) List Listed Below
Hydrochloric Acid (15%) FTSI Acidizing Listed Below
Water FTSI Carrier/Base Fluid Water 7732-18-5 100 87.0576 52,539,200.0
BIOC111139A FTSI Biocide Listed Below
Aromatic aldehyde Proprietary 10 0.00005613 33.872
Phosphonic Acid, {Nitrilotris (methylene)} Tris 6419-19-8 35 0.0085407 5154.31
Distillates (petroleum), hydrotreated light 64742-47-8 30 0.017184 10370.5
Distillates (petroleum), hydrotreated light 64742-47-8 30 0.017184 10370.5
Aromatic aldehyde Proprietary 10 0.00005613 33.872
Phosphorous Acid 10294-56-1 2 0.00048804 294.532
Organic amine resin salt Proprietary 30 0.00016838 101.617
Phosphonic Acid, {(Dimethylamino) Methylene} Bis - 29712-30-9 5 0.0012201 736.329
Silica Substrate 14808-60-7 100 12.5046 7,546,490.0
Dimethylformamide 68-12-2 10 0.00005613 33.872
Alcohols, C11-14-iso-, C13-rich, ethoxylated 78330-21-9 5 0.00286399 1728.42
Ethanol 64-17-5 5 0.00105706 637.937
Quaternary ammonium compound Proprietary 10 0.00005613 33.872
Ethylene Glycol 107-21-1 30 0.00016838 101.617
Isopropanol 67-63-0 30 0.00016838 101.617
Phosphonic Acid, {Nitrilotris (methylene)} Tris 6419-19-8 35 0.0085407 5154.31
Phosphorous Acid 10294-56-1 2 0.00048804 294.532
Hydrochloric Acid 7647-01-0 15 0.0501738 30279.8
Organic amine resin salt Proprietary 30 0.00016838 101.617
Benzyl-(C12-C16 Alkyl)-Dimethyl-Ammonium Chloride 68424-85-1 30 0.00634239 3827.62
Dimethylformamide 68-12-2 10 0.00005613 33.872
Ethylene Glycol 107-21-1 30 0.00016838 101.617
Alcohols, C11-14-iso-, C13-rich, ethoxylated 78330-21-9 5 0.00286399 1728.42
Glutaralehyde 111-30-8 10 0.00211413 1275.88
Phosphonic Acid, {(Dimethylamino) Methylene} Bis - 29712-30-9 5 0.0012201 736.329
Quaternary ammonium compound Proprietary 10 0.00005613 33.872
CS-1000 FTSI Scale Inhibitor Listed Below
CI-150 FTSI Acid Corrosion Inhibitor Listed Below
FRW-1450 FTSI Polymer Listed Below
2 Sand (Proppant) FTSI Proppant Listed Below
EMC PP EMC Pipe on pipe Listed Below
Water FTSI Carrier/Base Fluid Water 7732-18-5 100 88.7274 191,828,000.0
Phosphonic Acid, {(Dimethylamino) Methylene} Bis - 29712-30-9 5 0.000864614 1869.29
Organic amine resin salt Proprietary 30 0.000151322 327.157
Butyl cellozolve Proprietary 5 0.00010813 233.776
Alcohols, C11-14-iso-, C13-rich, ethoxylated 78330-21-9 5 0.00322607 6974.75
Ethanol 64-17-5 5 0.00105661 2284.39
Phosphorous Acid 10294-56-1 2 0.000345846 747.717
Isopropanol 67-63-0 30 0.000151322 327.157
Phosphonic Acid, {(Dimethylamino) Methylene} Bis - 29712-30-9 5 0.000864614 1869.29
Alcohols, C11-14-iso-, C13-rich, ethoxylated 78330-21-9 5 0.00322607 6974.75
Aromatic aldehyde Proprietary 10 0.00005044 109.052
Ethylene Glycol 107-21-1 30 0.000151322 327.157
Phosphorous Acid 10294-56-1 2 0.000345846 747.717
Petroleum Naphtha 64742-47-8 80 0.00173007 3740.41
Amides, From Diethylenetriamone,
alkenoic Acid and tall oil fatty acids
Proprietary 20 0.000432518 935.103
Glutaralehyde 111-30-8 10 0.00211322 4568.78
Benzyl-(C12-C16 Alkyl)-Dimethyl-Ammonium Chloride 68424-85-1 30 0.00633967 13706.3
Quaternary ammonium compound Proprietary 10 0.00005044 109.052
Aromatic aldehyde Proprietary 10 0.00005044 109.052
Hydrochloric Acid 7647-01-0 15 0.0450909 97486.3
Butyl cellozolve Proprietary 5 0.00010813 233.776
Distillates (petroleum), hydrotreated light 64742-47-8 30 0.0193564 41848.5
Organic amine resin salt Proprietary 30 0.000151322 327.157
Silica Substrate 14808-60-7 100 10.8663 23,493,000.0
Phosphonic Acid, {Nitrilotris (methylene)} Tris 6419-19-8 35 0.0060523 13085
Petroleum Naphtha 64742-47-8 80 0.00173007 3740.41
Ethylene Glycol 107-21-1 30 0.000151322 327.157
Quaternary ammonium compound Proprietary 10 0.00005044 109.052
Phosphonic Acid, {Nitrilotris (methylene)} Tris 6419-19-8 35 0.0060523 13085
Dimethylformamide 68-12-2 10 0.00005044 109.052
Amides, From Diethylenetriamone,
alkenoic Acid and tall oil fatty acids
Proprietary 20 0.000432518 935.103
Distillates (petroleum), hydrotreated light 64742-47-8 30 0.0193564 41848.5
CS-1000 FTSI Scale Inhibitor Listed Below
CI-150 FTSI Acid Corrosion Inhibitor Listed Below
FRW-1450 FTSI Polymer Listed Below
Other Chemical(s) Listed Above See Trade Name(s) List Listed Below
BIOC111139A FTSI Biocide Listed Below
Hydrochloric Acid (15%) FTSI Acidizing Listed Below

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2019 EQT PROD CO 1,811,640.00 358 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2018 EQT PROD CO Other Oil & Gas Wastes 0.95 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Other Oil & Gas Wastes 4.84 Tons LANDFILL 100419
2018 EQT PROD CO Drilling Fluid Waste 650.00 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Drill Cuttings 1,020.14 Tons LANDFILL 100277
2018 EQT PROD CO Other Oil & Gas Wastes 5.90 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 EQT PROD CO Other Oil & Gas Wastes 2.38 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE ORDER 2016-415
2018 EQT PROD CO Produced Fluid 96.22 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2018 EQT PROD CO Other Oil & Gas Wastes 34.76 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 39.75 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Synthetic Liner Materials 3.50 Tons LANDFILL 100277
2018 EQT PROD CO Produced Fluid 0.08 Tons RESIDUAL WASTE PROCESSING FACILITY 301280
2019 EQT PROD CO Produced Fluid 38.94 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019 EQT PROD CO Produced Fluid 4.80 Bbl RESIDUAL WASTE PROCESSING FACILITY
2019 EQT PROD CO Produced Fluid 42.22 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Produced Fluid 64.25 Bbl LANDFILL SWF 1032-WV0109
2019 EQT PROD CO Produced Fluid 7,653.76 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 19.60 Tons RESIDUAL WASTE PROCESSING FACILITY ODNR 2015-511
2019 EQT PROD CO Other Oil & Gas Wastes 72.19 Bbl LANDFILL 100172
2019 EQT PROD CO Other Oil & Gas Wastes 40.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Synthetic Liner Materials 10.01 Tons LANDFILL 100277
2019 EQT PROD CO Other Oil & Gas Wastes 10.48 Bbl LANDFILL SWF 1032-WV0109
2019 EQT PROD CO Produced Fluid 421.91 Bbl LANDFILL 100172
2019 EQT PROD CO Produced Fluid 87.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Waste Water Treatment Sludge 160.03 Tons STORAGE PENDING DISPOSAL OR REUSE MID0209062814
2019 EQT PROD CO Produced Fluid 16.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 2,212.27 Bbl LANDFILL 100663
2019 EQT PROD CO Synthetic Liner Materials 27.43 Tons LANDFILL 100419
2019 EQT PROD CO Produced Fluid 222.77 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2019 EQT PROD CO Other Oil & Gas Wastes 227.04 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2587321 Primary Facility 2017-04-26 Routine/Partial Inspection No Violations Noted On 4/24/17 a RTPT inspection was conducted of the Harold Haywood site. The following was observed.

>Multiple areas along the access road bear sparse or patchy vegetation increasing risk of erosion. No violation, remediation recommended.

>A topsoil pile near the pad entrance is only partially stabilized with straw. No violation, remediation recommended.

> Drilling activity was concluded at the time of inspection and removal of drilling and completion equipment was underway.

> The AST remained on site at time of inspection.

2688508 Primary Facility 2018-01-30 Routine/Complete Inspection No Violations Noted On 1/30/18 a routine complete of the Haywood Pad was conducted, the following was observed:

>>Substantial equipment was found stored around the site including multiple lifts and vehicles as well as numerous lights, generators, and tanks. An above ground storage tank was found on site as well. Most equipment had adequate secondary containment. Some stored equipment did not, any leaked or spilled fluids would constitute a violation.

>>Wells on site appeared to be in various stages of completion with no rig on site.

2699030 Primary Facility 2017-09-05 Administrative/File Review No Violations Noted On 9/5/17 an administrative inspection related to the Harold Haywood was conducted regarding test results related to complaint ID 328174. No evidence was found in the sample results suggesting impact to the water supply by oil and gas activity.
2715257 Primary Facility 2018-04-06 Drilling/Alteration No Violations Noted Cellar Tech auger rig drilled a 30" well bore and set 26" conductor casing at 40 ft. on 4/5/18.
2719525 Primary Facility 2018-04-18 Drilling/Alteration No Violations Noted Falcon Drilling Rig #20 moved onto this well on 4/14/18 and resumed drilling at 52 ft. KB on 4/16/18. The 18 5/8" casing was set at 384 ft. on 4/16/18 and cemented to surface with 45 bbls returned. The 13 3/8" casing was set at 467 ft. on 4/17/18 and cemented to surface with36 bbls returned. Coal was found from 422 ft. To 430 ft. A basket was set at 387 ft. Currently at 520 ft. and nippling up BOP's.
2722801 Primary Facility 2018-03-27 Complaint Inspection No Violations Noted On 3/27/18 a complaint inspection was conducted in relation to the Harold Haywood Well Site in response to CTS ID: 332966. Sample 3401-071 was collected for chemistry and biological analysis.
2723585 Primary Facility 2018-04-26 Drilling/Alteration No Violations Noted Falcon Drilling Rig #20. The 9 5/8" casing was set at 2093 ft. on 4/20/18 and cemented to surface with 23 bbls returned. TD was at 5350 ft. on 4/23/18.
2760871 Primary Facility 2018-08-07 Drilling/Alteration No Violations Noted Patterson-UTI Drilling Rig #294 began moving onto location on 8/1/18 and moved onto this well on 8/5/18. Currently rigging up and preparing to resume drilling.
2762720 Primary Facility 2018-08-13 Drilling/Alteration No Violations Noted Patterson-UTI Drilling Rig #294 resumed drilling at 5368 ft. KB on 8/9/18. KOP was at 6158 ft. EOB was at 7932 ft. MD (7332 ft. TVD). Currently at 12,241 ft. and drilling ahead.
2767035 Primary Facility 2018-08-24 Drilling/Alteration No Violations Noted Patterson-UTI Drilling Rig #294. TD was at 13,540 ft. MD (7317 ft. TVD) on 8/13/18. The 5 1/2" casing was set at 13,538 ft. Estimated TOC at 5000 ft.
2767391 Primary Facility 2018-08-15 Routine/Partial Inspection No Violations Noted On 8/15/18 a routine partial inspection of the Harold Haywood Site was conducted in response to increased activity at the pad. The following was observed:

>>The site was in drilling phase at the time of inspection. High activity was noted on the pad. A drilling rig was active on site at the time of inspection.

>>Multiple containers of contaminated equipment were found off containment resulting in minor impacts to the pad. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the operator failed to control regulated materials in a manner that prevents pollution to the ground and Waters of the Commonwealth. Any equipment with the potential to cause pollution including equipment contaminated with petroleum residues should be placed and stored on containment. Runoff from improperly stored equipment will result in violations.

>>Staining found on the pad near the office trailer suspected to be petroleum based (material was hydrophobic and greasy). This constitutes a viola

2790142 Primary Facility 2018-05-01 Administrative/File Review No Violations Noted On 5/1/18 an administrative inspection related to the Haywood site was conducted to analyze results from sample 3401071 related to complaint ID 332966 collected on 3/27/18. Sample analysis found that while the water did not meet state drinking water standards no clear indicators of oil and gas impact were present.
2805063 Primary Facility 2018-11-02 Complaint Inspection Violation(s) Noted On 11/2/18 a complaint inspection of the Harold Haywood well site was conducted in response an operator reported spill. The following was observed:

>>On 10/31/18 an EQT representative reported that 15 gallons of "impaired water" was spilled to the pad.

>>At the time of inspection an operator representative reported that the standing water along the bottom of the AST was found to have very high conductivity during a routine check. The impacted water was pumped out. Field testing of standing water at the time of inspection found water at the site of the initial spill remained impacted with conductivity reading at roughly 1040us. Per the representative the standing water at the time of inspection was believed to be rain water from storms after the initial spill. The impacted water at the time inspection was substantially greater than the 15 gallons initially reported and was in addition to the initial spill. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the opera

2831222 Primary Facility 2019-01-22 Compliance Evaluation No Violations Noted On 1/22/19 a compliance evaluation inspection of the Harold Haywood Well Site was conducted in response to violations recorded on 11/2/18 and 12/16/16. The following was observed:

>>No apparent residual impact related to spill violations from either date were observed. Containment around the AST on site may conceal further impact. No violation.

>>Violations related to non-GPU containment were remediated around time of 12/16/16 inspection and addressed with the operator at the time.

>>GPUs on site continued to lack containment at the time of inspection including on units installed post 10/2016. Violations ongoing.

2863340 Primary Facility 2018-09-07 Administrative/File Review No Violations Noted On 9/7/18 an administrative inspection related to the Harold Haywood Pad was conducted to analyze sample and case information pertaining to a water supply complaint (CTS ID: 332966). No evidence of impact was found.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2805063 833939 2018-11-02 78a64a(b) Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
833939 366600 NOV - Notice of Violation

For data sources see[8]

References