37-125-28289

Well Details

Well ID: 37-125-28289
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Carroll Township
Operator Name: EQT PROD CO
Well Pad ID: 148479
Farm/Lease Name: HAYWOOD MON110H25
License Status:
Spud Date:
Permit Date: 2017-08-07
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.178869
Longitude: -79.976056

For data sources see[1][2][3]

Well History

Date Event
2017-08-07 New Permit Application
2017-08-14 Performed Spud Operation

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2017 EQT PROD CO 0.00 0 0.00 0 0.00 0
2019 EQT PROD CO 4,431,490.00 286 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2018 EQT PROD CO Other Oil & Gas Wastes 56.89 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Synthetic Liner Materials 14.21 Tons LANDFILL 100419
2018 EQT PROD CO Drilling Fluid Waste 125.00 Bbl INJECTION DISPOSAL WELL 34-157-25511
2018 EQT PROD CO Drill Cuttings 1,939.09 Tons LANDFILL 100277
2018 EQT PROD CO Other Oil & Gas Wastes 5.90 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 EQT PROD CO Other Oil & Gas Wastes 34.76 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Servicing Fluid 30.00 Bbl RESIDUAL WASTE PROCESSING FACILITY
2018 EQT PROD CO Other Oil & Gas Wastes 0.95 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Other Oil & Gas Wastes 2.38 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE ORDER 2016-415
2018 EQT PROD CO Produced Fluid 96.22 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2018 EQT PROD CO Synthetic Liner Materials 12.24 Tons LANDFILL 100277
2018 EQT PROD CO Other Oil & Gas Wastes 15.93 Tons LANDFILL 100277
2018 EQT PROD CO Drilling Fluid Waste 1,040.00 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 121.18 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019 EQT PROD CO Other Oil & Gas Wastes 40.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 19.60 Tons RESIDUAL WASTE PROCESSING FACILITY ODNR 2015-511
2019 EQT PROD CO Produced Fluid 1,229.26 Bbl LANDFILL 100663
2019 EQT PROD CO Waste Water Treatment Sludge 160.03 Tons STORAGE PENDING DISPOSAL OR REUSE MID0209062814
2019 EQT PROD CO Produced Fluid 6,000.92 Bbl LANDFILL SWF 1032-WV0109
2019 EQT PROD CO Produced Fluid 27.15 Bbl LANDFILL CID: 29084
2019 EQT PROD CO Other Oil & Gas Wastes 5.24 Bbl LANDFILL 100663
2019 EQT PROD CO Produced Fluid 286.81 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 53.81 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Other Oil & Gas Wastes 160.23 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 12.26 Bbl RESIDUAL WASTE PROCESSING FACILITY
2019 EQT PROD CO Produced Fluid 12,261.62 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Synthetic Liner Materials 35.88 Tons LANDFILL 100419
2019 EQT PROD CO Produced Fluid 151.83 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Other Oil & Gas Wastes 77.43 Bbl LANDFILL 100172
2019 EQT PROD CO Produced Fluid 622.03 Bbl LANDFILL 100172
2019 EQT PROD CO Produced Fluid 724.95 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2587333 Primary Facility 2017-04-26 Routine/Partial Inspection No Violations Noted On 4/24/17 a RTPT inspection was conducted of the Harold Haywood site. The following was observed.

>Multiple areas along the access road bear sparse or patchy vegetation increasing risk of erosion. No violation, remediation recommended.

>A topsoil pile near the pad entrance is only partially stabilized with straw. No violation, remediation recommended.

> Drilling activity was concluded at the time of inspection and removal of drilling and completion equipment was underway.

> The AST remained on site at time of inspection.

2631387 Primary Facility 2017-08-28 Drilling/Alteration No Violations Noted Cellar Tech auger rig

Drilled a 30” wellbore and set 26” conductor casing at 40 ft. on 8/14/16.

2688512 Primary Facility 2018-01-30 Routine/Complete Inspection No Violations Noted On 1/30/18 a routine complete of the Haywood Pad was conducted, the following was observed:

>>Substantial equipment was found stored around the site including multiple lifts and vehicles as well as numerous lights, generators, and tanks. An above ground storage tank was found on site as well. Most equipment had adequate secondary containment. Some stored equipment did not, any leaked or spilled fluids would constitute a violation.

>>Wells on site appeared to be in various stages of completion with no rig on site.

2699034 Primary Facility 2017-09-05 Administrative/File Review No Violations Noted On 9/5/17 an administrative inspection related to the Harold Haywood was conducted regarding test results related to complaint ID 328174. No evidence was found in the sample results suggesting impact to the water supply by oil and gas activity.
2722810 Primary Facility 2018-03-27 Complaint Inspection No Violations Noted On 3/27/18 a complaint inspection was conducted in relation to the Harold Haywood Well Site in response to CTS ID: 332966. Sample 3401-071 was collected for chemistry and biological analysis.
2723579 Primary Facility 2018-04-26 Drilling/Alteration No Violations Noted Falcon Drilling Rig #20 moved onto this well on 4/24/18 and resumed drilling at 52 ft. KB. The 18 5/8" casing was set at 384 ft. on 4/25/18 and cemented to surface with36 bbls returned. The 13 3/8" casing was set at 474 ft. on 4/26/18 and cemented to surface with 28 bbls returned. Currently at 520 ft. and waiting on cement.
2725907 Primary Facility 2018-05-03 Drilling/Alteration No Violations Noted Falcon Drilling Rig #20. The 9 5/8" casing was set at 2096 ft. on 4/29/18 and cemented to surface with 25 bbls returned. A Casing Annulus Packer was set in the 9 5/8" casing from 1239 ft. to 1249 ft. KOP was at 4550 ft. Currently at 5567 ft. MD and drilling ahead.
2767015 Primary Facility 2018-08-24 Drilling/Alteration No Violations Noted Patterson-UTI Drilling Rig #294 moved onto this well on 8/16/18' and resumed drilling at 6693 ft. MD KB. KOP was at 4550 ft. (with air rig). EOB was at 8408 ft. MD (7326 ft. TVD). Currently at 22,842 ft. and drilling ahead.
2767395 Primary Facility 2018-08-15 Routine/Partial Inspection No Violations Noted On 8/15/18 a routine partial inspection of the Harold Haywood Site was conducted in response to increased activity at the pad. The following was observed:

>>The site was in drilling phase at the time of inspection. High activity was noted on the pad. A drilling rig was active on site at the time of inspection.

>>Multiple containers of contaminated equipment were found off containment resulting in minor impacts to the pad. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the operator failed to control regulated materials in a manner that prevents pollution to the ground and Waters of the Commonwealth. Any equipment with the potential to cause pollution including equipment contaminated with petroleum residues should be placed and stored on containment. Runoff from improperly stored equipment will result in violations.

>>Staining found on the pad near the office trailer suspected to be petroleum based (material was hydrophobic and greasy). This constitutes a viola

2790144 Primary Facility 2018-05-01 Administrative/File Review No Violations Noted On 5/1/18 an administrative inspection related to the Haywood site was conducted to analyze results from sample 3401071 related to complaint ID 332966 collected on 3/27/18. Sample analysis found that while the water did not meet state drinking water standards no clear indicators of oil and gas impact were present.
2799666 Primary Facility 2018-11-02 Complaint Inspection Violation(s) Noted On 11/2/18 a complaint inspection of the Harold Haywood well site was conducted in response an operator reported spill. The following was observed:

>>On 10/31/18 an EQT representative reported that 15 gallons of "impaired water" was spilled to the pad.

>>At the time of inspection an operator representative reported that the standing water along the bottom of the AST was found to have very high conductivity during a routine check. The impacted water was pumped out. Field testing of standing water at the time of inspection found water at the site of the initial spill remained impacted with conductivity reading at roughly 1040us. Per the representative the standing water at the time of inspection was believed to be rain water from storms after the initial spill. The impacted water at the time inspection was substantially greater than the 15 gallons initially reported and was in addition to the initial spill. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the opera

2831216 Primary Facility 2019-01-22 Compliance Evaluation No Violations Noted On 1/22/19 a compliance evaluation inspection of the Harold Haywood Well Site was conducted in response to violations recorded on 11/2/18 and 12/16/16. The following was observed:

>>No apparent residual impact related to spill violations from either date were observed. Containment around the AST on site may conceal further impact. No violation.

>>Violations related to non-GPU containment were remediated around time of 12/16/16 inspection and addressed with the operator at the time.

>>GPUs on site continued to lack containment at the time of inspection including on units installed post 10/2016. Violations ongoing.

2863344 Primary Facility 2018-09-07 Administrative/File Review No Violations Noted On 9/7/18 an administrative inspection related to the Harold Haywood Pad was conducted to analyze sample and case information pertaining to a water supply complaint (CTS ID: 332966). No evidence of impact was found.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2799666 833648 2018-11-02 78.57(a) Environmental Health & Safety
2799666 833649 2018-11-02 78.54 Environmental Health & Safety
2799666 833650 2018-11-02 78a64a(b) Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
833648 369536 NOV - Notice of Violation
833649 369536 NOV - Notice of Violation
833650 366600 NOV - Notice of Violation

For data sources see[7]