X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-125-28380

Well Details

Well ID: 37-125-28380
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Carroll Township
Operator Name: EQT PROD CO
Well Pad ID: 145213
Farm/Lease Name: R. SMITH MON99H22
License Status:
Spud Date:
Permit Date: 2017-10-12
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.164844
Longitude: -79.944536

For data sources see[1][2][3]

Well History

Date Event
2017-10-12 New Permit Application
2017-10-16 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2018-03-31 2018-05-06 7,326 12,528,700 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Contains no hazardous substances
in concentrations above
cut-off values according to the competent authority
Proprietary 100 0.00262525 3046.08
Gum Guar 9000-30-0 50 0.000868213 1007.39
Ammonium Persulfate 7727-54-0 13 0.00009421 109.312
Ethoxylated Alcohol Proprietary 5 0.00424161 4921.54
Hydrotreated Light Distillate (Petroleum) 64742-47-8 65 0.00112868 1309.6
Ammonium Persulfate 7727-54-0 100 0.00000474 5.5
Calcium Nitrate.4H2O 13477-34-4 100 0.0398599 46249.5
Poly(oxy-1,2-ethanediyl), alpha-tridecyl-omega-hydroxy-branche
d
69011-36-5 5 0.00424161 4921.54
Silica Substrate 14808-60-7 100 9.36465 10,865,800.0
Contains no hazardous substances
in concentrations above
cut-off values according to the competent authority
Proprietary 100 0.00262525 3046.08
Calcium Nitrate.4H2O 13477-34-4 100 0.0398599 46249.5
Ethylene Glycol 107-21-1 60 0.0153368 17795.2
Gum Guar 9000-30-0 50 0.000868213 1007.39
Hydrochloric Acid 7647-01-0 15 0.0557341 64668.3
2,2,4-trimethylpentane-1,3-diol monoisobutyrate 25265-77-4 7 0.00005913 68.608
Benzenesulfonic Acid, Dodecyl-,
Compound with 2-aminoethanol (1:1)
26836-07-7 7 0.00005913 68.608
Ethylene Glycol 107-21-1 13 0.00009421 109.312
Hydrotreated Light Petroleum Distillate 64742-47-8 30 0.0254497 29529.3
Ammonium Persulfate 7727-54-0 100 0.00000474 5.5
Hydrotreated Light Distillate (Petroleum) 64742-47-8 65 0.00112868 1309.6
MC-S2510T Multi-Chem Scale Inhibitor Listed Below
MX-5-3886 Multi-Chem Bacteria Treatment Listed Below
LD-2950 Multi-Chem Friction Reducer Listed Below
MX-5-2349 Multi-Chem Friction Reducer Breaker Listed Below
Hydrochloric Acid (15%) ProFrac Acidizing Listed Below
ProVis 4.0 ProFrac Guar Slurry Listed Below
Water ProFrac Carrier/Base Fluid Water 7732-18-5 100 90.1076 104,552,000.0
Sand (Proppant) ProFrac Proppant Listed Below
ProBreak 100 ProFrac Instant Breaker Listed Below
Other Chemical(s) Listed Above See Trade Name(s) List Listed Below
DireCT NewPark Drilling Fluids Lubricant Listed Below
MX-8-4543 Multi-Chem Bacteria Treatment Listed Below

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2017 EQT PROD CO 0.00 0 0.00 0 0.00 0
2018 EQT PROD CO 1,430,383.00 184 0.00 0 0.00 0
2019 EQT PROD CO 1,424,468.00 319 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2017 EQT PROD CO Drill Cuttings 672.42 Tons LANDFILL 100277
2017 EQT PROD CO Drilling Fluid Waste 520.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Drill Cuttings 128.18 Tons LANDFILL 100172
2018 EQT PROD CO Soil Contaminated by Oil 25.94 Tons LANDFILL CID # 28726
2018 EQT PROD CO Produced Fluid 1,906.91 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 49.76 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 10.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 EQT PROD CO Other Oil & Gas Wastes 10.45 Bbl RESIDUAL WASTE PROCESSING FACILITY
2018 EQT PROD CO Drilling Fluid Waste 310.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 2.54 Tons LANDFILL 100419
2018 EQT PROD CO Drill Cuttings 936.63 Tons LANDFILL 100277
2018 EQT PROD CO Other Oil & Gas Wastes 371.36 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 10.45 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Soil Contaminated by Oil & Gas Related Spills 25.94 Tons LANDFILL CID # 28726
2018 EQT PROD CO Produced Fluid 118.62 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2018 EQT PROD CO Produced Fluid 15.48 Tons RESIDUAL WASTE PROCESSING FACILITY ORDER 2016-29
2018 EQT PROD CO Produced Fluid 305.67 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Synthetic Liner Materials 55.18 Tons LANDFILL 100419
2018 EQT PROD CO Drilling Fluid Waste 130.00 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 112.02 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 0.43 Tons RESIDUAL WASTE PROCESSING FACILITY 301280
2019 EQT PROD CO Produced Fluid 23.83 Bbl INJECTION DISPOSAL WELL 34-167-29543
2019 EQT PROD CO Produced Fluid 263.36 Bbl RESIDUAL WASTE PROCESSING FACILITY ODNR 2015-511
2019 EQT PROD CO Produced Fluid 2.62 Bbl INJECTION DISPOSAL WELL 34-167-28462
2019 EQT PROD CO Other Oil & Gas Wastes 19.41 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Other Oil & Gas Wastes 75.00 Bbl RESIDUAL WASTE PROCESSING FACILITY ODNR 2015-511
2019 EQT PROD CO Produced Fluid 43.27 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 4.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Other Oil & Gas Wastes 202.50 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 1,157.32 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 29.04 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Other Oil & Gas Wastes 2.90 Tons LANDFILL 100172
2019 EQT PROD CO Produced Fluid 16.63 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2650213 Primary Facility 2017-10-20 Drilling/Alteration No Violations Noted Cellar Tech auger rig drilled 30" well bore and set 26" conductor casing at 40 ft. on 10/16/17.
2654373 Primary Facility 2017-10-27 Drilling/Alteration No Violations Noted Fountain Quail Rig #8 moved onto this well on 10/22/17 and resumed drilling at 53 ft. KB. The 18 5/8" casing was set at 284 ft. on 10/24/17. Operator was unable to displace cement to surface. Tagged cement at 115 ft. and grouted to surface. The 13 3/8" casing was set at 439 ft. on 10/26/17 and grouted to surface above a basket. Coal was found from 344 ft. to 354 ft. A basket was set at 321 ft. Currently at 493 ft. and testing BOP's and doing rig repair.
2657301 Primary Facility 2017-11-06 Drilling/Alteration No Violations Noted Fountain Quail Drilling Rig #8 The 9 5/8" casing was set at 1676 ft. on 10/29/17 and cemented to surface with 23 bbls returned. The Casing Annulus Packer was set in the 9 5/8" casing string from 1266 ft. to 1276 ft. TD was at 5929 ft. on 11/2/17.
2660202 Primary Facility 2017-11-09 Routine/Complete Inspection No Violations Noted On 11/10/17 a routine complete inspection of the R. Smith well site was conducted in response to notification additional drilling on site. The following was observed:

>>A box tank was found near the impoundment with no containment. Remediation recommended, no violation.

>>A new top soil stock pile was noted on site. It was stabilized with straw at the time of inspection.

>>The soil stock pile was noted to not have any functional controls below it other than an adequate vegetated strip. Decomposed CFS should be removed, repaired, or replaced. No violation.

>>Drilling was ongoing at the site at the time of inspection.

2678454 Primary Facility 2018-01-03 Drilling/Alteration No Violations Noted Patterson-UTI Drilling rig #277 moved onto this well on 12/27/17 and resumed drilling at 5940 ft. KB. KOP was at 5940 ft. EOB was at 7850 ft. MD (7303 ft. TVD). Currently at 19,590 ft. and drilling ahead.
2685609 Primary Facility 2018-01-18 Drilling/Alteration No Violations Noted Patterson-UTI Drilling Rig #277. Drilled to 20,624 ft. MD on 1/5/18. Had to work pipe out of hole. TOOH on 1/11/18. TIH with clean out BHA and TOOH on 1/17/18. Currently testing BOP's.
2685618 Primary Facility 2018-01-19 Drilling/Alteration No Violations Noted Patterson-UTI Drilling Rig # 277. Operator decided TD will be 20,624 ft. MD (7178 ft. TVD). Currently running 5 1/2" casing.
2691591 Primary Facility 2018-02-02 Drilling/Alteration No Violations Noted Patterson-UTI Drilling Rig #277. The 5 1/2" casing was set at 20,431 ft. on 1/19/18. Estimated TOC is at 5802 ft.
2705663 Primary Facility 2018-03-13 Routine/Partial Inspection No Violations Noted On 3/14/18 a routine complete inspection of the R. Smith Well Site was conducted in response to a notification of proposed construction activity on the pad. The following was observed:

>>The site was in a high activity phase at the time of inspection drilling appeared to be completed and the site was in apparent transition to post drilling activities. No drilling rig was present on site at the time of inspection.

>>Construction of a proposed AST had not begun at the time of inspection.

>>Many water trucks were present on site in association with the attached impoundment.

2738552 Primary Facility 2018-05-16 Incident- Response to Accident or Event No Violations Noted On 5/16/18 an incident inspection of the R. Smith well site was conducted in response to a spill reported by the operator on 5/14/18. The following was observed:

>>The operator reported that roughly 35 gallons of mixed rain water and produced water was spilled to the pad when a section of containment was moved without being drained first. Fluids were spread over a large area of the pad along the area in front of the production units per discussion with Mike Cromley at the time of inspection. This does constitute a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the operator failed to control regulated materials in a manner that prevents prevents pollution to the ground or Waters of the Commonwealth however, the violation is regarded as immediately corrected.

>>Site inspection found no residual evidence of the spill. The operator reported that all visibly impacted gravel from the spill area had been removed (roughly two clamshell dumpsters).

2747566 Primary Facility 2018-06-29 Routine/Partial Inspection No Violations Noted On 6/29/18 a routine partial inspection of the R. Smith Well Site was conducted in response to concerns about runoff raised by a nearby resident. The following was observed:

>>An unstabilized soil pile near the corner of the pad with a newly improved drain. Controls below the pile were absent though the vegetation was sufficient. No violation, remediation recommended.

>>Another only partially stabilized soil pile with no controls below the pile was located along the accessory pad access road. No controls beyond vegetation were present below the soil pile. No violation, monitoring recommended.

>>An AST was present on the accessory pad.

>>The pad was active at the time of inspection with drilling preparations ongoing. A sound wall was present around the pad perimeter.

2762073 Primary Facility 2018-08-02 Routine/Complete Inspection No Violations Noted On 8/2/18 a complaint response inspection was conducted of the R Smith well site in response to reported concerns of inappropriate drainage from the pad. WQSS John Carson accompanied. The following was observed:

>>A top soil pile on the access road to the accessory pad remained lacking vegetation and with spotty temporary stabilization. The vegetative strip below remains in good condition. Remediation recommended, no violation.

>>Emptying partially filled containment is encouraged to aid in identifying any possible leaks. No violation.

>>No evidence of excessive or unpermitted runoff from the pad was found.

>>Box in containment appears to be collecting emergency blowdown. If so it should be properly marked. No violation.

For data sources see[8]

References