If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-129-28391 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.489778,"lon":-79.578736,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Westmoreland | |
Municipality: Washington Township | |
Operator Name: CNX GAS CO LLC | |
Well Pad ID: 148574 | |
Farm/Lease Name: HUTCHINSON 4C | |
License Status: | |
Spud Date: | |
Permit Date: 2010-07-15 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 40.489778 | |
Longitude: -79.578736 |
Date | Event |
---|---|
2010-07-15 | New Permit Application |
2010-08-09 | Performed Spud Operation |
2011-03-02 | Drilling Completion |
2012-08-29 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-08-19 | 2011-08-19 | 7,565 | 5,640,877 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Acetic Acid | Calfrac Well Services | Acid | Acetic Acid | 99.00 | 0.03 | ||
DWP-944 | Calfrac Well Services | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.00188000 | ||
Polyethylene glycol | 25322-68-3 | 60.00 | 0.00565000 | |||||
DWP-111 | Calfrac Well Services | Viscosity Additive | Polysaccharide Suspension | 0.03 | ||||
DWP-612 | Calfrac Well Services | Friction Reduction | Long Chain Polyacrylamide | 0.08 | ||||
DWP-901 | Calfrac Well Services | Gel Breaker | Peroxydisulfuric acid, diammonium salt | 7727-54-0 | 95.00 | 0.01 | ||
DAP-901 | Calfrac Well Services | Scale Inhibitor | Ammonium chloride | 12125-02-9 | 10.00 | 0.00140000 | ||
Organic Phosphonate | 30.00 | 0.00421000 | ||||||
Methanol | 67-56-1 | 30.00 | 0.00421000 | |||||
Oxyalkylated Polyamine | 5.00 | 0.00070000 | ||||||
Amine Salt | 5.00 | 0.00070000 | ||||||
Phosphoric Acid Ammonium Salt | 5.00 | 0.00070000 | ||||||
Water | Calfrac Well Services | Carrier | Water | 100.00 | 94.63 | |||
Sand | Calfrac Well Services | Proppant | Sand | 100.00 | 4.27 | |||
DAP-923 | Calfrac Well Services | Corrosion Inhibitor | Propargyl alcohol | 107-19-7 | 10.00 | 0.00004000 | ||
Olefin | 5.00 | 0.00002000 | ||||||
Fatty Acids | 30.00 | 0.00012000 | ||||||
Polyoxyalkylenes | 30.00 | 0.00012000 | ||||||
Thiourea polymer | 68527-49-1 | 30.00 | 0.00012000 | |||||
Methanol | 67-56-1 | 60.00 | 0.00024000 | |||||
Hydrochloric Acid | Calfrac Well Services | Acid | Hydrochloric acid | 7647-01-0 | 3.00 | 0.79 | ||
DWP-938 | Calfrac Well Services | Surfactant | Soap | 0.07 | ||||
DWP-204 Clay Control | Calfrac Well Services | Buffer | Formic acid | 64-18-6 | 7.00 | 0.00025000 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CONSOL GAS CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CONSOL GAS CO | 305,919.00 | 73 | 0.00 | 0 | 0.00 | 0 |
2012 | CNX GAS CO LLC | 825,307.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2013 | CNX GAS CO LLC | 546,784.65 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | CNX GAS CO LLC | 438,858.24 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | CNX GAS CO LLC | 389,314.04 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CNX GAS CO LLC | 325,644.14 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CNX GAS CO LLC | 273,700.72 | 363 | 0.00 | 0 | 0.00 | 0 |
2018 | CNX GAS CO LLC | 272,064.23 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CNX GAS CO LLC | 196,632.67 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | CONSOL GAS CO | Drilling Fluid Waste | 711.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
2012 | CONSOL GAS CO | Produced Fluid | 626.73 Bbl | INJECTION DISPOSAL WELL | 34-007-22038 |
2012 | CNX GAS CO LLC | Produced Fluid | 759.91 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CONSOL GAS CO | Fracturing Fluid Waste | 17.12 Tons | LANDFILL | 06-08438 |
2012 | CNX GAS CO LLC | Produced Fluid | 76.51 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2012 | CONSOL GAS CO | Produced Fluid | 404.95 Bbl | INJECTION DISPOSAL WELL | 34-155-23584 |
2012 | CONSOL GAS CO | Fracing Fluid Waste | 5,313.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CNX GAS CO LLC | Produced Fluid | 678.85 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CNX GAS CO LLC | Produced Fluid | 211.77 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2013 | CNX GAS CO LLC | Produced Fluid | 103.00 Bbl | INJECTION DISPOSAL WELL | 34-007-22038 |
2013 | CNX GAS CO LLC | Produced Fluid | 104.13 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2013 | CNX GAS CO LLC | Produced Fluid | 100.00 Bbl | INJECTION DISPOSAL WELL | 34-119-28776 |
2013 | CNX GAS CO LLC | Produced Fluid | 275.59 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2014 | CNX GAS CO LLC | Produced Fluid | 1,160.69 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CNX GAS CO LLC | Produced Fluid | 119.34 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2014 | CNX GAS CO LLC | Produced Fluid | 117.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23732 |
2015 | CNX GAS CO LLC | Produced Fluid | 97.11 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2015 | CNX GAS CO LLC | Produced Fluid | 246.87 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2015 | CNX GAS CO LLC | Produced Fluid | 673.92 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CNX GAS CO LLC | Produced Fluid | 656.39 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CNX GAS CO LLC | Produced Fluid | 237.45 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2017 | CNX GAS CO LLC | Produced Fluid | 102.00 Bbl | REUSE (AT WELL PAD) | |
2017 | CNX GAS CO LLC | Produced Fluid | 115.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-10 |
2017 | CNX GAS CO LLC | Produced Fluid | 111.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-32 |
2018 | CNX GAS CO LLC | Produced Fluid | 36.51 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2018 | CNX GAS CO LLC | Produced Fluid | 45.50 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2018 | CNX GAS CO LLC | Produced Fluid | 11.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | CNX GAS CO LLC | Other Oil & Gas Wastes | 2.50 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018 | CNX GAS CO LLC | Produced Fluid | 58.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2018 | CNX GAS CO LLC | Produced Fluid | 296.15 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018 | CNX GAS CO LLC | Produced Fluid | 81.62 Bbl | REUSE (AT WELL PAD) | |
2019 | CNX GAS CO LLC | Produced Fluid | 45.14 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2019 | CNX GAS CO LLC | Produced Fluid | 124.59 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2019 | CNX GAS CO LLC | Produced Fluid | 40.92 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2019 | CNX GAS CO LLC | Produced Fluid | 26.64 Bbl | REUSE (AT WELL PAD) | |
2019 | CNX GAS CO LLC | Produced Fluid | 42.16 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | CNX GAS CO LLC | Produced Fluid | 7.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2019 | CNX GAS CO LLC | Produced Fluid | 48.84 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1926207 | Primary Facility | 2010-11-05 | Drilling/Alteration | No Violations Noted | MARCELLUS - drilling/E&S ok/ID&pit ok |
1952938 | Primary Facility | 2011-02-22 | Drilling/Alteration | No Violations Noted | Rig shut down with electrical issues at time of inspection. Currently at 7900' MD - 8 3/4" hole. Proposed base of curve at 8400' MD. Closed loop system with synthetic mud being utilized. Drilling and frack pits lined and freeboard maintained. E/S controls in place and functioning as per available plan. |
1973839 | Primary Facility | 2010-08-31 | Routine/Complete Inspection | No Violations Noted | Hole C will begin tomorrow. E&S ok. Pit sound. |
2014665 | Primary Facility | 2011-10-28 | Routine/Complete Inspection | No Violations Noted | Drilling had been completed, wells were in the process of being equipped for production. All E&S controls had been implemeneted as outlined in the E&S plan. There was no accelerated erosion or sedimentation observed in relation to the access road or well-site. |
2067984 | Primary Facility | 2012-05-15 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the site appear to be in the beginning phases of restoration. The E&S plan was onsite and the BMP's were installed and properly maintained. The flow back pit adjacent to the well pad appears to be regarded and backfilled. |
2092894 | Primary Facility | 2012-08-20 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well was drilled and equipped for production. The well apparatus and brine tanks located onsite appear to be in sound condition. At the time of inspection the site had been regraded, seeded, and mulched. The vegetation is growing nicely at this time but does not meet the 70% uniform vegetative criteria needed to complete restoration. During the inspection the department notes that the erosion and sedimentation plan was onsite and all BMPs were still installed as outline in the E&S plan. All BMPs appear to be in sound condition and functioning properly. No accelerated erosion or sedimentation observed in relation to the well pad or access road at the time of inspection. The department suggest the operator continue to monitor the site after significant precipitation events and weekly to ensure the integrity of the site is maintained. |
2125978 | Primary Facility | 2012-12-27 | Routine/Complete Inspection | No Violations Noted | Well operating and properly identified. |
2154575 | Primary Facility | 2013-04-04 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well was drilled and equipped for production. The well apparatus and brine tanks located onsite appear to be in sound condition. At the time of inspection the site had been regraded, seeded, and mulched. The Department also notes that trees have been planted on the site. No accelerated erosion or sedimentation observed in relation to the well pad or access road at the time of inspection. The Department suggest the Operator continue to monitor the site after significant precipitation events and weekly to ensure the integrity of the site is maintained. |
2212801 | Primary Facility | 2013-10-16 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well was drilled and equipped for production. The well apparatus and brine tanks located onsite appear to be in sound condition. At the time of inspection the site had been regraded, seeded, and mulched. The Department also notes that trees have been planted on the site. No accelerated erosion or sedimentation observed in relation to the well pad or access road at the time of inspection. The Department suggest the Operator continue to monitor the site after significant precipitation events and weekly to ensure the integrity of the site is maintained. |
2357584 | Primary Facility | 2015-04-02 | Routine/Complete Inspection | No Violations Noted | Well operating and properly identified. |
2519312 | Primary Facility | 2016-09-13 | Routine/Complete Inspection | No Violations Noted | At the time of inspection well appears equipped for production. Well tag present and affixed in a permanent manner. Brine tank located on site within secondary containment and appears to be structurally sound. Site stable, no E& S issues in relation to site and/or access road. |
2551794 | Primary Facility | 2017-01-11 | Routine/Complete Inspection | No Violations Noted | Well tagged-shut in. Well head casing-production unit-tank battery-dike containment looked ok. |
2685721 | Primary Facility | 2018-01-22 | Routine/Complete Inspection | No Violations Noted | At the time of inspection well equipped for production. Brine tank within secondary containment and appears structurally sound. No E&S issues.
ESCGP active. |
2790364 | Primary Facility | 2018-10-17 | Routine/Complete Inspection | No Violations Noted | Well appears to be in good working condition. |
2794506 | Primary Facility | 2018-10-25 | Routine/Complete Inspection | No Violations Noted | Well appears to be in good working condition. |
2851510 | Primary Facility | 2019-03-11 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The well head casing, piping, production set equipment, containment dike and large fluid collection tank look ok. |
For data sources see[8]