{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.640753,"lon":-75.810942,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Wyoming | |
Municipality: Nicholson Township | |
Operator Name: CHIEF OIL & GAS LLC | |
Well Pad ID: 149079 | |
Farm/Lease Name: POLOVITCH UNIT | |
License Status: Plugged and Abandoned | |
Spud Date: 2011-06-14 | |
Permit Date: 2011-05-04 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.640753 | |
Longitude: -75.810942 |
Date | Event |
---|---|
2011-05-04 | New Permit Application |
2011-06-12 | Performed Spud Operation |
2011-07-12 | Drilling Completion |
2011-09-29 | DEVIATED |
2015-07-27 | Begin Plugging |
2018-11-08 | Finished Plugging |
2018-12-13 | Fully Plugged |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 600.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2011 | CHIEF OIL & GAS LLC | Drilling Fluid Waste | 360.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2011 | CHIEF OIL & GAS LLC | Drill Cuttings | 363.69 Tons | LANDFILL | 301626 |
2011 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 119.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2018 | CHIEF OIL & GAS LLC | Spent Lubricant Waste | 12.81 Bbl | LANDFILL | 301358 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1980302 | Primary Facility | 2011-06-13 | Drilling/Alteration | No Violations Noted | Ziegenfuss on site. Current depth 30' - no water. |
1981708 | Primary Facility | 2011-06-20 | Drilling/Alteration | No Violations Noted | "20" at 140' sanded in UDI Rig 58, Comp. Man - Kenny George |
1984434 | Primary Facility | 2011-06-24 | Drilling/Alteration | No Violations Noted | Comp. Man - Jim Quisenberry Drillers log good at 2512' |
1985110 | Primary Facility | 2011-07-01 | Drilling/Alteration | No Violations Noted | UDI #58, depth = 7138' |
1986572 | Primary Facility | 2011-07-07 | Drilling/Alteration | No Violations Noted | UDI Rig 58, Comp. Man - Kenny George |
1987802 | Primary Facility | 2011-07-11 | Drilling/Alteration | No Violations Noted | getting ready to cement 5 1/2" prod csg. |
1990418 | Primary Facility | 2011-07-25 | Routine/Complete Inspection | No Violations Noted | Vent pipe on 5 1/2" X 95/8" annulus runs to frac tank. |
2005966 | Primary Facility | 2011-09-27 | Routine/Complete Inspection | No Violations Noted | |
2026318 | Primary Facility | 2011-12-09 | Complaint Inspection | Pending | This well is not in production (others on site are). There are 2 vents, cellar is filled with gravel. There is 46 psi on annulus vent.? which annulus? Cellar is filled w/ gravel. |
2029333 | Primary Facility | 2011-12-15 | Complaint Inspection | Pending | This well is not in prod. There are 2 annular vents, but cellar is filled in. Eric Rooney took isotopic samples. |
2029338 | Primary Facility | 2011-12-19 | Follow-up Inspection | Violation(s) Noted | Went with Kevin Costello and met with Rich Adams/Chief rep. Cellar has been dug up to identify which annulus the vents go to. |
2029343 | Primary Facility | 2011-12-22 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | On site to take flow readings w/ oriface meter. Met Ralph Larson, and Jon Hafer / Chief reps. |
2051400 | Primary Facility | 2012-03-15 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | Cellar is dug out, no water. Orange fence is on ground. |
2062425 | Primary Facility | 2012-04-12 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | Well is not producing. Cellar is partially dug out, no water. |
2062432 | Primary Facility | 2012-03-27 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | Not producing. Cellar dug out, no water. 3 vents. |
2064981 | Primary Facility | 2012-04-27 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | 3 annular vents, no guages, open. |
2067576 | Primary Facility | 2012-05-14 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | Well is not producing. 3 annular vents - open. Cellar partially dug out - no water. |
2076977 | Primary Facility | 2012-06-18 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | Not producing. Has 3 annular vents, all are shut w/ temp., press.recorders installed. The #1 vent (13 3/8 X 9 5/8") alsohas press. guage w/ 180 psi. |
2078692 | Primary Facility | 2012-06-20 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | No water in cellar. All press/temp recorders have been removed and vents have been opened. Talked to Rich Adams, Chief, and he says bubbles were from leaky valve under gravel. Cellar will be dug up and flooded to check, soon. Also, Chief will have data for us soon and set up meeting to discus and see how to procede( a week or so). |
2080477 | Primary Facility | 2012-06-26 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | no change since last inspection. |
2081757 | Primary Facility | 2012-07-09 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | Cellars dug out. No change since last insp. The valve on the annular vent is exposed, don't know(can't tell) if it leaks. None of the wells have press. recorders. Called R. Adams(Chief) to see what progress they are making on VIOS. He called back that we will hear from them- not quite ready with info. Also check on leaky valve - will call when flooding cellar. |
2084484 | Primary Facility | 2012-07-03 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | Cellar has been dug out. No water. There is a valve on line but can't tell if it leaks. Cellar on 4H has also been dug out. |
2086661 | Primary Facility | 2012-07-24 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | No change since last insp. |
2087770 | Primary Facility | 2012-07-30 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | Not a prod. well. 3 annular vents, open. Muddy water in cellar, no bubbles. No press guages. No change since last insp. |
2097231 | Primary Facility | 2012-08-30 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | On site w/ Kevin Costello(DEP), Ralph Larsen(Chief) & Jon Hafer(Chief Consultant) to witness flow tests and pressure test on annuli. Shut in 3 annuli for 20 min. - 9 5/8 x 5 1/2" = 0 psi, 9 5/8 x 13 3/8" = 10 psi, and 20 x 13 3/8" = 0 psi. |
2103126 | Primary Facility | 2012-09-14 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | No change since last insp. Cellar is dug out - very small amount of water in cellar - no bubbles. 3 annular vents, no pressure guages, all are vented to tanks. |
2112198 | Primary Facility | 2012-10-24 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | Equip. & people on site - finishing up pipeline work & moving out equipment. |
2175536 | Primary Facility | 2013-06-11 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | Well is not producing. 3 annular vents are open. |
2196363 | Primary Facility | 2013-08-14 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | Not producing. Water in cellar. |
2213504 | Primary Facility | 2013-10-01 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | On site w/ Eric Rooney, DEP and Jon Hafer, Chief to collect isotopic samples from various annuli. Shut in for 17+ hours, since about 4:30PM yesterday. |
2240193 | Primary Facility | 2014-01-24 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | No activity on site. |
2263075 | Primary Facility | 2014-04-11 | Routine/Complete Inspection | No Violations Noted | Well has been drilled and we have recieved a well record, but has not been completeds. It is still on active status in e- facts. |
2321207 | Primary Facility | 2014-11-04 | Follow-up Inspection | Violation(s) Noted | |
2670039 | Primary Facility | 2017-12-11 | Follow-up Inspection | No Violations Noted | There was no activity occurring at the site during the inspection. I was accompanied by Jon Sassi (OGI) and consulted with Ken Kennedy (OGI). There were no violations noted pertaining to this well. If you have any questions, please contact me. |
2703214 | Primary Facility | 2018-02-22 | Compliance Evaluation | In Compliance with Schedule | Arrived onsite at 15:15. Onsite to check on progress of re plumbing of all (4) wells annular vents to surface in preparation for long term venting phase as discussed and agreed to in the Depts. meeting with Chief O&G of 2/14/18. All (4) wells, the Polovitch 1H, 1V, 4H and 5H, have had their (20" x 13 3/8"), (13 3/8" x 9 5/8") and (9 5/8" / WB) annular vents plumbed to surface via 2" vents. Vents had been fitted with ball valves and Tees w/ needle valves to access vents for sampling and eventual PBUTs. The Dept. will be meeting Chief O&G Rep., Jon Hafer back at pad tomorrow morning at 09:30 to obtain gas samples off all annuli, where gas is present, for Isotopic analysis. Chief O&G has had all annular spaces and vents purged of fluid and were shut in earlier today in preparation for tomorrows sampling event. (See attached, "As Plugged" Well Bore Schematics for individual wells for plugging details as of 2/14/18). All previous, deteriorated pad liner and debris have been removed from location. Location was fou |
2703226 | Primary Facility | 2018-02-23 | Compliance Evaluation | In Compliance with Schedule | Arrived onsite at 09:00. Upon arrival met up with Chief O&G Rep., Jonathan Hafer and D.E.P. Geologist, Eric Rooney. Onsite to initiate the 1st long term, approx. 90 day, venting period as agreed to in meeting of 2/14/18 with Chief O&G. All (4) wells annuli vents, the (20" x 13 3/8"), (13 3/8" x 9 5/8") and (9 5/8" / WB) were re-plumbed to surface and shut-in yesterday in preparation for todays sampling. Mr. Hafer explained that he would be taking gas samples off all the wells annular vents to send off for analysis. Following Mr. Hafers collection of annuli samples, I performed gas screenings at all (4) wells annuli using a ALTAIR 5X gas meter calibrated on 2/5/18. Gas was detected at the following wells annuli:
1H: (13 x 9) = 100% LEL, 100% CH4, 4H: (13 x 9) = 100 % LEL, 30 % CH4, 5H: (13 x 9) = 100 % LEL, 8 % CH4, Following sample collection and gas screenings, all (4) wells annuli were opened to vent to atmosphere. This long term venting period will extend for ~ 90 days. Operator will then be performing |
2775963 | Primary Facility | 2018-08-31 | Compliance Evaluation | In Compliance with Schedule | Arrived onsite at 11:00. Upon arrival met with Chief O&G Rep., Jonathan Hafer to conclude the 7 day PBUTs being performed on all (4) wells annuli vents, the (20" x 13 3/8"), (13 3/8" x 9 5/8") and (9 5/8" / WB). This is the 2nd PBUT being performed after (2) full 90 day, long term venting periods. Pre-shut in test gas screenings were performed at all wells annular vents on 8/24/18 by Mr. Hafer using a Rae Systems Multi-Rae gas meter, calibrated that morning. The only annuli where gas was detected are listed below:
1H: (13x9) = 3.1% CH4, 51% LEL 1V: (9/WB) = 1.6% CH4, 36% LEL 4H: (13x9) = 1.9% CH4, 70% LEL 5H: (13x9) = 6.6% CH4, 100% LEL Today, the ending 7 day PBUT results were: 1H: (20x13)= 0.40 psi, (13x9)= 12.95 psi, (9/WB)= 0.44 psi. 1V: (20x13)= -0.10 psi, (13x9)= -2.0 psi, (9/WB)= 0.45 psi. 4H: (20x13)= 0.10 psi, (13x9)= 11.10 psi, (9/WB)= 0.70 psi. 5H: (20x13)= 0.65 psi, (13x9)= 5.2 psi, (9/WB)= 0.75psi. - Mr. Hafer explained that he would be collecting samples off all the wells annular vents to sen |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2029338 | 627794 | 12/19/2011 | 2011-12-19 | 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days | Administrative | GMI COA executed 10/23/2017 |
2321207 | 710152 | 11/04/2014 | 2014-11-04 | 78.73A - Operator shall prevent gas and other fluids from lower formations from entering fresh groundwater. | Environmental Health & Safety | Actually 78.73(b) |
2321207 | 710153 | 11/04/2014 | 2014-11-04 | 78.81D1 - Failure to maintain control of anticipated gas storage reservoir pressures while drilling through reservoir or protective area | Administrative | Actually 78.81 (a)(2)+(3) |
2321207 | 710155 | 11/04/2014 | 2014-11-04 | 78.85 - Inadequate, insufficient, and/or improperly installed cement | Environmental Health & Safety | Actually 78.85(a)(5) |
2321207 | 710156 | 11/04/2014 | 2014-11-04 | 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days | Administrative | |
2321207 | 799777 | 11/04/2014 | 2014-11-04 | CSL 401 - PROHIBITION AGAINST OTHER POLLUTIONS - Discharged substance of any kind or character resulting in pollution of Waters of the Commonwealth. | Environmental Health & Safety |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
627794 | 279011 | NOV - Notice of Violation | |||||
710152 | 317500 | NOV - Notice of Violation | |||||
710152 | 358810 | COA - Consent Order and Agreement | 2017-10-23 | $178,622.00 | $178,622.00 | ||
710153 | 317500 | NOV - Notice of Violation | |||||
710153 | 358810 | COA - Consent Order and Agreement | 2017-10-23 | $178,622.00 | $178,622.00 | ||
710155 | 317500 | NOV - Notice of Violation | |||||
710156 | 317500 | NOV - Notice of Violation | |||||
710156 | 358810 | COA - Consent Order and Agreement | 2017-10-23 | $178,622.00 | $178,622.00 | ||
799777 | 317500 | NOV - Notice of Violation | Administrative Close Out | 2017-10-23 | |||
799777 | 358810 | COA - Consent Order and Agreement | 2017-10-23 | $178,622.00 | $178,622.00 |
For data sources see[7]