X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-169-25685

Well Details

Well ID: 34-169-25685
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Wayne Township
Operator Name: JAMES R BERNHARDT INC
Well Pad ID:
Farm/Lease Name: TOM GEORGE
License Status: Producing
License Date: 2015-08-21
Spud Date: 2015-10-21
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2015-10-30
Well Total Depth: 5557.00 ft
Configuration: Vertical
Latitude: 40.860000
Longitude: -81.960000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2015-08-21 Proposed Formations:TREMPEALEAU, Issued Date:8/21/2015, Expired Date:8/20/2017 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2015-10-30
Completion Report Received 2016-02-11
Construction Permit Expires 2017-08-20
Record Last Modified 2017-10-23

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2016-02-11 5561 5590 45
5561 5590 45
5561 5590 45

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2015-12-16 H2O 0 30005 Gal 20540 Producers Service Corporation Producer's Service Corporation pumped a fracture stimulation with an acid spearhead and proppant sand down the well. The well was acidized and broken down once previously so no breakdown pressure was recorded. No issues were noted on the job. The fluid was cross linked gel. No acid total was noted by Producer's.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2016 JAMES R BERNHARDT INC 0.00 346.00 92
2017 JAMES R BERNHARDT INC 0.00 549.00 365
2018 JAMES R BERNHARDT INC 0.00 288.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2016 JAMES R BERNHARDT INC Brine 1188 92
2017 JAMES R BERNHARDT INC Brine 2330 365
2018 JAMES R BERNHARDT INC Brine 1328 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1219935755 2018-9-13 0:00: PW No Violations
-146005631 2015-12-15 0:00 CT No Violations
-392918642 2018-5-25 0:00: PW No Violations
-663450186 2017-7-14 0:00: PL No Violations
-87220098 2016-9-21 0:00: PW No Violations
0075055785 2017-07-14 Production Wells No Violations Inspected production well on 07/14/2017. The tank battery consists of 2-210 bbl steel tanks, 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike. The well is equipped with a pump jack with a natural gas-powered hitmiss motor. The wellhead is located within a small earthen dike. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
0087220098 2016-09-21 Production Wells No Violations Visited location on 09/21/2016, as a rig was noted on location while driving by. Davis Well Service was onsite, rigged up, and pulling rods and tubing to work on pumping issues. No problems were noted at the time of the inspection.
0146005631 2015-12-15 Completion Testing No Violations Visited location on 12/15/2015 to check on the status of operations at the location. Bishop Well Service was on-site. A frac job is scheduled for Wednesday morning.
0392918642 2018-05-25 Production Wells No Violations Inspected production well on 05/25/2018. The tank battery consists of 2-210 bbl steel tanks, 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike. The well is equipped with a pump jack with a natural gas-powered motor. The well was pumping at the time of the inspection. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
0422365828 2015-11-23 Completion Testing No Violations Arrived on location on 11/23/2015 to check on the status of operations at the well. Bishop Well Service was on-site swabbing the well.
0663450186 2017-07-14 Preliminary Restoration No Violations Inspected production well on 07/14/2017. All drilling equipment and debris have been removed, pits closed, and the well placed into production. Preliminary restoration passes.
0868225391 2015-11-20 Completion Testing No Violations Visited location on 11/20/2015 to check on the status of operations at the well. Bishop Well Service was on-site. Producers Service Corp. was on-site shortly after. Rigged up Producers Service Corp. and begin acid job.
0937287731 2015-11-18 Completion Testing No Violations Arrived on location on 11/18/2015 to check on the status of operations at the well. Bishop Well Service and Appalachian Well Services were on-site, rigged up, and logging the hole upon my arrival. CBL showed top of production casing cement at 4,920. Prep to perforate the casing.
1219935755 2018-09-13 Production Wells No Violations Inspected production well on 09/13/2018 with NW Region Supervisor Steve Ochs. The tank battery consists of 2-210 bbl steel tanks, 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike. The well is equipped with a pump jack with a natural gas-powered motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
1385909329 2015-10-26 Drill / Deepen / Reopen No Violations Visited location on 10/26/2015 to check on the status of drilling operations. Poulson Drilling was drilling a 7 7/8 hole ahead at 3,066. Gas was encountered at ~2,400.
1418373206 2016-07-28 Production Wells No Violations Inspected production well on 07/28/2016. The tank battery consists of 2-210 bbl steel tanks and 1-vertical separator, located within an earthen dike. The well is equipped with a pump jack with a natural gas-powered motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
1565781851 2019-8-12 0:00: PW No Violations
1641489242 2015-10-21 Casing String Witnessed No Violations Arrived on location 10/21/2015 to witness the conductor casing cement job. Rig was unable to run casing due to problems with the hole. Decision made to pull casing out, ream, and make another attempt.
1822460297 2020-6-10 0:00: PW No Violations
422365828 2015-11-23 0:00 CT No Violations
75055785 2017-7-14 0:00: PW No Violations
868225391 2015-11-20 0:00 CT No Violations
937287731 2015-11-18 0:00 CT No Violations

For data sources see[9]

References